![Ubisys 7047 Скачать руководство пользователя страница 25](http://html2.mh-extra.com/html/ubisys/7047/7047_reference-manual_3150151025.webp)
25
www.ubisys.de
7.5.
APDU Definitions
7.5.1.
Tag Identification Commands
7.5.1.1.
Get Data Command
Standard: PC/SC: Interoperability Specification for ICCs and Personal Computer Systems, Part 3,
Section 3.2.2.1.3.
Request
Command
CLA
INS
P
1
P
2
L
e
Get UID
FFh
CAh 00h
00h
Expected length of UID
Get all historical bytes (ISO14443, excl. CRC)
FFh
CAh 00h
00h
Expected length of historical bytes
Response
Data
SW1
SW2
Response codes
SW1
SW2
Meaning
90h
00h
The complete data is returned.
62h
82h
The complete data is returned. End of data reached, i.e. Le is larger
than the length of the UID/historical bytes.
6Ch
Wrong length requested, i.e. Le is less than the length of the
UID/historical bytes. SW2 indicates the correct length.
6Ah
81h
Function not supported.
7.5.2.
Configuration commands
Valid for: all standards, independent of active tag
7.5.2.1.
Get Configuration
Request
CLA
INS
P
1
P
2
L
e
FFh
33h
00h
Configuration item
ignored
Response
Configuration value
SW1
SW2
Содержание 7047