Ubiquiti TouchSwitch Poe TS-5-POE Скачать руководство пользователя страница 10

8

5-Port TOUGHSwitch

 PoE Quick Start Guide

Accessing the Configuration Interface

Connect to the Configuration Interface by performing the 
following steps: 
1.  Ensure that your computer (or other host machine) is 

connected to the Management port on the TOUGHSwitch. 

Note:

 By default, you can configure the TOUGHSwitch 

via any port; however, we recommend the Management 

port. (Access to the Configuration Interface can be 

limited to the Management port only. You can configure 

this setting on the Device tab.)

2.  Configure the Ethernet adapter on your host system with a 

static IP address on the 192.168.1.x subnet (e.g., 192.168.1.100).

3.  Launch your web browser. Type https://192.168.1.20 in the 

address field. Press enter (PC) or return (Mac). 

4.  The login screen will appear. Enter ubnt in the Username and 

Password fields. Click Login.

The Configuration Interface will appear, allowing you to customize 
your settings as needed. You can enable PoE on the Ports tab.
Refer to the TOUGHSwitch PoE User Guide for instructions on 
configuring the TOUGHSwitch. The User Guide is available at 
documentation.ubnt.com

Содержание TouchSwitch Poe TS-5-POE

Страница 1: ...5 Port Power over Ethernet Managed Switch Model TS 5 POE ...

Страница 2: ......

Страница 3: ...eaturing 24V or 48V PoE TOUGHSwitch PoE Carrier TS 16 Carrier Two 8 Port TOUGHSwitch PoE PROs mounted in a rack For more information visit www ubnt com This Quick Start Guide is designed to guide you through the installation of the TOUGHSwitch and show you how to access the Configuration Interface Package Contents 5 Port TOUGHSwitch PoE M2 9x20 Screws Qty 2 M2 9 Anchors Qty 2 Carrier Class 5 Port ...

Страница 4: ...nagement Traffic between the Management port and numbered ports will be limited to 10 100 Mbps and under heavy load may cause performance degradation of the TOUGHSwitch USB Reserved for future use 1 5 10 100 1000 Mbps ports for switching and PoE also available for management by default Reset To reset to factory defaults press and hold the Reset button for more than five seconds while the unit is a...

Страница 5: ...If the link terminates the LED turns off until a link is re established If the unit reboots the LED will again indicate power until a link is established Amber Flashing Activity 1 5 PoE Off No Power over Ethernet Green 24V Power over Ethernet Speed Link Act Off No Link Amber Link Established at 10 100 Mbps Amber Flashing Link Activity at 10 100 Mbps Green Link Established at 1000 Mbps Green Flashi...

Страница 6: ...n Requirements Drill and 6 mm drill bit Phillips screwdriver Instructions To mount the TOUGHSwitch on a wall 1 Use a 6 mm drill bit to drill two holes 60 mm apart 2 Insert the M2 9 Anchors into the holes 3 Use a Phillips screwdriver to secure a M2 9x20 Screw to each anchor Leave a clearance of approximately 3 mm between each screw head and its anchor 60 mm 3 mm Note You can also mount the TOUGHSwi...

Страница 7: ...ck it into place Grounding the TOUGHSwitch Optional The TOUGHSwitch is grounded through the Power Adapter however you can add optional ESD grounding for enhanced ESD protection 1 Insert a ground wire not included through a corner slot 2 Twist tie to secure the ground wire to the TOUGHSwitch 3 Secure the other end of the ground wire to a grounding block ...

Страница 8: ...rt Guide Connecting Power 1 Connect the power connector of the Power Adapter to the Power port of the TOUGHSwitch 2 Connect the Power Cord to the power port on the Power Adapter Connect the other end of the Power Cord to a power outlet ...

Страница 9: ...agement port of the TOUGHSwitch 2 Connect Ethernet cables from the Ethernet ports of your devices to the numbered ports of the TOUGHSwitch Note PoE is disabled by default on all numbered ports and is not available on the Management port To enable PoE on the appropriate ports use the Ports tab in the Configuration Interface ...

Страница 10: ...ort only You can configure this setting on the Device tab 2 Configure the Ethernet adapter on your host system with a static IP address on the 192 168 1 x subnet e g 192 168 1 100 3 Launch your web browser Type https 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Click Login The Configuration Interface wi...

Страница 11: ...hod Passive Button Reset USB Port 2 0 Type A Reserved for Future Use Processor MIPS24K 400 MHz System Memory 64 MB Code Storage 8 MB Certifications CE FCC IC Wall Mount Yes Operating Temperature 25 to 55 C 13 to 131 F Operating Humidity 90 Non Condensing PoE Configurable Per Port Management N A Ports 1 5 Off 24V LEDs Per Port Management Link Activity Ports 1 5 PoE Speed Link Activity Networking In...

Страница 12: ...ent Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of th...

Страница 13: ...out obtaining a Return Materials Authorization RMA number from UBIQUITI NETWORKS Products returned without an RMA number will not be processed and will be returned to Buyer freight collect UBIQUITI NETWORKS shall have no obligation to make repairs or replacement necessitated by catastrophe fault negligence misuse abuse or accident by Buyer Buyer s customers or any other parties The warranty period...

Страница 14: ...ed in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada This Class A digital apparatus complies with Canadian ICES 003 To reduce potential radio interference to o...

Страница 15: ...isposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2002 96 EC verlangt dass technische Ausrüstung die direkt am Gerät und oder an de...

Страница 16: ...e jeter ce matériel ainsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d...

Страница 17: ... Finnish UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deuts...

Страница 18: ... príslu né ustanovenia Smernice 1999 5 ES Svenska Swedish Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cualesquiera...

Страница 19: ......

Страница 20: ...t Email support ubnt com Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com w w w u b n t c o m 2012 Ubiquiti Networks Inc All rights reserved ...

Отзывы: