Safety Notices

1.  Read, follow, and keep these instructions.
2.  Heed all warnings.
3.  Only use attachments/accessories specified by the manufacturer.

WARNING:

 Do not use this product in a location that can 

be submerged by water. 

WARNING:

 Avoid using this product during an electrical 

storm. There may be a remote risk of electric shock from 
lightning. 

Electrical Safety Information

1.  Compliance is required with respect to voltage, frequency, and current 

requirements indicated on the manufacturer’s label. Connection to a 
different power source than those specified may result in improper 
operation, damage to the equipment or pose a fire hazard if the 
limitations are not followed.

2.  There are no operator serviceable parts inside this equipment. Service 

should be provided only by a qualified service technician.

3.  This equipment is provided with a detachable power cord which has 

an integral safety ground wire intended for connection to a grounded 
safety outlet.
a.  Do not substitute the power cord with one that is not the provided 

approved type. Never use an adapter plug to connect to a 2-wire 
outlet as this will defeat the continuity of the grounding wire. 

b.  The equipment requires the use of the ground wire as a part of the 

safety certification, modification or misuse can provide a shock 
hazard that can result in serious injury or death.

c.  Contact a qualified electrician or the manufacturer if there 

are questions about the installation prior to connecting the 
equipment.

d.  Protective earthing is provided by Listed AC adapter. Building 

installation shall provide appropriate short-circuit backup 
protection.

e.  Protective bonding must be installed in accordance with local 

national wiring rules and regulations.

Limited Warranty

UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) warrants that the 
product(s) furnished hereunder (the “Product(s)”) shall be free from defects 
in material and workmanship for a period of one (1) year from the date 
of shipment by UBIQUITI NETWORKS under normal use and operation. 
UBIQUITI NETWORKS’ sole and exclusive obligation and liability under 

Содержание PBE-M5-400-ISO

Страница 1: ...5 GHz airMAX Bridge with 400 mm RF Isolated Reflector Model PBE M5 400 ISO...

Страница 2: ...ISO Nylon Insert Lock Nuts Qty 4 Gigabit PoE 24V 0 5A with Mounting Bracket Power Cord Quick Start Guide The PBE M5 400 ISO Antenna Feed has a thin gray ring around the center of the cap to differenti...

Страница 3: ...Hardware Overview Bottom View Cable Door Rear Housing Antenna Feed Ethernet Port Release Button Slot Mounting Bracket Release Button Reflector Alignment Pins Reset Button Radome Technology...

Страница 4: ...ss the Release button first LEDs Signal In airOS you can modify the wireless signal strength threshold values for each LED on the Advanced tab under Signal LED Thresholds The default values are shown...

Страница 5: ...rage using the 3 dBi Antenna Feed only Installation Requirements 13 mm wrench Shielded Category 5 or above cabling should be used for all wired Ethernet connections and should be grounded through the...

Страница 6: ...racket counterclockwise until the alignment holes in the dish and bracket align with each other 2 For added support in high wind environments insert four Screws with Washers into the holes in the Refl...

Страница 7: ...r Housing into the Mounting Bracket 4 View the Reflector from the front Ensure that the three hooks indicated below of the Rear Housing are fully engaged with the inner wall of the Reflector and locke...

Страница 8: ...ousing 6 Attach the Antenna Feed a Insert the Antenna Feed into the Rear Housing and push until it locks into place with a click b Lightly pull the Antenna Feed to ensure that it is locked into place...

Страница 9: ...Clamp to the Adjustment Bracket a Hold the Adjustment Bracket with its clamps facing you and the Elevation Indicators towards the top b Insert the Carriage Bolts through the holes of the Adjustment Br...

Страница 10: ...he Adjustment Bracket against the pole b Slide the slot of the Pole Clamp over the adjacent Carriage Bolt c Tighten the Flange Nuts of the bolts to 25 N m to secure the Adjustment Bracket to the pole...

Страница 11: ...10 Insert the Pivot Pins on the inside of the Adjustment Bracket into the Mounting Bracket Slots Pivot Pin one on each side of Adjustment Bracket Mounting Bracket Slot...

Страница 12: ...11 Secure the Adjustment Bracket to the Mounting Bracket using the four Hex Bolts with Washers...

Страница 13: ...eflector with the Arrow at the top of the Radome Guide the Radome s side and top tabs over the Reflector rim and slide the Radome down onto the Reflector Arrow Notch Radome Side Tab Reflector Rim Rado...

Страница 14: ...Radome over the Reflector rim Bottom Tabs 14 Adjust the elevation angle a Loosen the four Hex Bolts on both sides of the antenna b Pivot the antenna until the Elevation Indicator shows the desired ele...

Страница 15: ...Connect the Ethernet cable from the device s Ethernet port to the POE port of the Gigabit PoE adapter 2 Connect an Ethernet cable from your LAN to the adapter s LAN port 3 Connect the Power Cord to t...

Страница 16: ...8 1 x subnet 3 Launch your web browser and type https 192 168 1 20 in the address field Press enter PC or return Mac https 192 168 1 20 4 Enter ubnt in the Username and Password fields Select your Cou...

Страница 17: ...lick OK to confirm Customize additional settings as needed to complete the configuration For additional details on the airOS Configuration Interface refer to the User Guide available at www ubnt com d...

Страница 18: ...er s responsibility to make sure the device is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna a...

Страница 19: ...er Supply 24V 0 5A Gigabit PoE Adapter Included Power Method Passive PoE Pairs 4 5 7 8 Return Wind Survivability 200 km h 125 mph Wind Loading 559 N 200 km h 125 7 lbf 125 mph Mounting Pole Mounting K...

Страница 20: ...a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity o...

Страница 21: ...received by Ubiquiti within 30 days of issuance of the RMA In addition the above warranty shall apply only if the product has been properly installed and used at all times in accordance and in all mat...

Страница 22: ...age buyer s selection of products including the Products for buyer s application and or failure of products including the Products to meet government or regulatory requirements Limitation of Liability...

Страница 23: ...user will be required to correct the interference at his own expense This radio transmitter FCC ID SWX PBE5M has been approved by FCC to operate with the antenna types listed below with the maximum p...

Страница 24: ...in 25 dBi RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 113 cm from all persons and must not be located or operating in conj...

Страница 25: ...will help prevent potential negative consequences to the environment and human health For more detailed information about the disposal of your old equipment please contact your local authorities waste...

Страница 26: ...que tout autre mat riel lectrique ou lectronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s territoriales L limination et le recyclage en bonne e...

Страница 27: ...nnish UBIQUITI NETWORKS vakuuttaa ett radiolaitetyyppi PBE M5 400 ISO on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen t ysimittainen teksti on saatavilla seuraavassa internetosoi...

Страница 28: ...aixo assinado a UBIQUITI NETWORKS declara que o presente tipo de equipamento de r dio PBE M5 400 ISO est em conformidade com a Diretiva 2014 53 UE O texto integral da declara o de conformidade est dis...

Отзывы: