background image

5. The EdgeSwitch Con guration Interface will appear. Click the System Settings tab.

6. Change the IP Address to a unique IP address. Click Apply.

ES-12F Quick Start Guide

×

Click for

Table of Contents

Содержание EdgeSwitch

Страница 1: ...or applications use Category 5 or above UTP cabling approved for indoor use For outdoor applications shielded Category 5 or above cabling should be used for all wired Ethernet connections and should b...

Страница 2: ...ti Network Management System UNMS Blue Ready for use connected to UNMS Steady Blue with Occasional Flashing Ready for use unable to connect to UNMS check connection to UNMS server Quickly Flashing Blu...

Страница 3: ...ults Power on Reset 1 Disconnect the power from the EdgeSwitch 2 While connecting the power to the EdgeSwitch hold the Reset button for about 15 seconds until the System LED ashes blue for two seconds...

Страница 4: ...Power Connect the included Power Cord to the Power port Hardware Installation Mounting in a Rack Optional 1 2 OR ES 12F Quick Start Guide Click for Table of Contents...

Страница 5: ...Connecting Power 1 ES 12F Quick Start Guide Click for Table of Contents...

Страница 6: ...2 Connecting SFP 1 ES 12F Quick Start Guide Click for Table of Contents...

Страница 7: ...2 3 ES 12F Quick Start Guide Click for Table of Contents...

Страница 8: ...ess If that fails then it will use the default fallback IP address 192 168 1 2 Proceed to the appropriate section DHCP or Fallback IP Address DHCP Use one of the following methods Set up the DHCP serv...

Страница 9: ...as needed For more information refer to the EdgeSwitch documentation which is available at ui com download edgemax Fallback IP Address 1 Ensure that your computer or other host system is connected to...

Страница 10: ...5 The EdgeSwitch Con guration Interface will appear Click the System Settings tab 6 Change the IP Address to a unique IP address Click Apply ES 12F Quick Start Guide Click for Table of Contents...

Страница 11: ...upgrade and back up your devices using a single application Get started at www unms com Speci cations ES 12F Dimensions 443 x 221 x 43 mm 17 44 x 8 70 x 1 69 Weight Rack Mount Brackets Included 2 68...

Страница 12: ...remote risk of electric shock from lightning Electrical Safety Information 1 Compliance is required with respect to voltage frequency and current requirements indicated on the manufacturer s label Con...

Страница 13: ...on This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection again...

Страница 14: ...Online Resources 2020 Ubiquiti Inc All rights reserved ES 12F Quick Start Guide Click for Table of Contents...