17
Chapter 7: Services Tab
airCam
™
Mini User Guide
Ubiquiti Networks, Inc.
•
Startup Delay
Specify initial time delay (in seconds)
until the first ICMP echo requests are sent by the Ping
Watchdog tool. The default value is
300
seconds.
The value of Startup Delay should be at least 60 seconds
as the network interface and wireless connection
initialization takes a considerable amount of time if the
airCam Mini is rebooted.
•
Failure Count to Reboot
Specify the number of ICMP
echo response replies. If the specified number of ICMP
echo response packets is not received continuously, the
Ping Watchdog tool will reboot the airCam Mini. The
default value is
3
.
SNMP Agent
Simple Network Monitor Protocol (SNMP) is used
in network management systems to monitor
network-attached devices for conditions that warrant
administrative attention. The airCam Mini contains an
SNMP agent which allows it to communicate to SNMP
manage applications for network provisioning.
The SNMP Agent provides an interface for device
monitoring using the Simple Network Management
Protocol (an application layer protocol that facilitates the
exchange of management information between network
devices). SNMP Agent allows network administrators to
monitor network performance, find and solve network
problems. For the purpose of equipment identification,
it is always a good idea to configure SNMP agents with
contact and location information:
Enable SNMP Agent
Select to enable the SNMP Agent.
•
SNMP Community
Specify the SNMP community
string. It is required to authenticate access to MIB
objects and functions as an embedded password. The
airCam Mini supports a Read-only community string
that gives read access to authorized management
stations to all the objects in the MIB except the
community strings, but does not allow write access.
The airCam Mini supports SNMP v1. The default SNMP
Community is
public
.
•
Contact
Specify the contact who that should be
notified in case an emergency situation arises.
•
Location
Specify the physical location of the airCam
Mini.
Web Server
The following Web Server parameters can be configured:
Use Secure Connection (HTTPS)
If checked Web server
will use secure HTTPS mode. HTTPS mode is unchecked by
default.
•
Secure Server Port
Defines the Web Server TCP/IP port
Use Secure Connection (HTTPS)
is enabled.
Server Port
Web Server TCP/IP port setting while using
HTTP mode.
Session Timeout
Specifies the maximum timeout before
the session expires. Once a session expires, you must login
again using the username and password.
SSH Server
The following SSH Server parameters can be configured:
Enable SSH Server
This option enables SSH access to the
airCam Mini.
•
Server Port
SSH service TCP/IP port setting.
•
Enable Password Authentication
When enabled, you
must authenticate using Administrator credentials in
order to grant SSH access to the airCam Mini, otherwise
an Authentication Key will be required.
•
Authorized Keys
Click
Edit
to import a public key file
working to get SSH access to the airCam Mini instead
of using an admin password. To do so, perform the
following steps:
1. Click
Choose File
to locate and select the key file, then
click
Import
.
2. Click
Save
to save your changes or
Close
to discard
your changes.
Telnet Server
The following Telnet Server parameters can be set:
Enable Telnet Server
This option activates the Telnet
access to the airCam Mini.
•
Server Port
Telnet service TCP/IP port setting.