background image

11

© 2023 Ubicquia, Inc.

    

EN:

 

AP6: 

Reinstall the clamp 

adjustment cover set aside in 

step 3.3 over the mounting clamp 

vertical adjustment screws by 

tabbing in the bottom hook and 

rotating inward.

  

ES: AP6: Vuelva a instalar la 

cubierta de ajuste de la abrazadera 

puesta a un lado en el paso 3.3 

sobre los tornillos de ajuste vertical 

de la abrazadera de montaje, 

fijando el gancho inferior y girando 

hacia adentro.

6.11

  

EN:

 Tighten the top screw of the 

dual-camera or clamp adjustment 

cover to 15 in-lbs torque using the 

3/16” Hex bit.

  

ES: Apriete el tornillo superior de 

la cubierta de ajuste de la doble 

cámara o abrazadera a un par de 

15 pulgadas-libras utilizando la 

broca hexagonal de 3/16”.

3/16”

7.1

  

EN:

 The installer will need to select 

which grounding option to use 

based on local regulations and 

guidelines, as well as selecting the 

correct grounding clamp based on 

arm type, diameter, etc. 

  

ES: El instalador tendrá que 

seleccionar la opción de conexión 

a tierra que va a utilizar en función 

de las normativas y directrices 

locales, así como seleccionar la 

abrazadera de conexión a tierra 

correcta en función del tipo de 

brazo, el diámetro, etc. 

7. Grounding Cable Installation

  Instalación del cable de tierra

EN: STOP! Ensure UbiHub is mounted, grounded, and secured firmly in 

place before moving on.

ES: ¡ALTO! Asegúrese de que el UbiHub está montado, conectado a 

tierra y fijado firmemente en su lugar antes de continuar.

EN: CAUTION:

 The unit must 

be grounded in accordance 

with the local codes or 

regulations defined by the local 

inspector. The surface where 

the grounding clamp will be 

installed must be prepared to 

ensure metal to metal contact.

ES: PRECAUCIÓN: La unidad 

debe estar conectada a tierra 

de acuerdo con los códigos 

locales o normas definidas por 

el inspector local. La superficie 

donde la pinza de conexión a 

tierra se instalará debe estar 

preparada para garantizar el 

contacto entre metales.

Содержание ubihub APAI

Страница 1: ...on Manual Manual de instalaci n EN Before installation please read this instructional guide completely and save for future reference ES Antes de la instalaci n lea completamente esta gu a de instrucci...

Страница 2: ...d Tools not Included Herramientas necesarias no incluidas Helmet Casco Gloves Guantes Safety Tether rated to at least 10lbs Correa de seguridad con una capacidad de al menos 10 libras Measure Instrume...

Страница 3: ...s ES Saque el Ubihub de la caja y col quelo sobre la espuma protectora como se muestra Aseg rese de que los rieles de montaje est n orientados hacia arriba Min 1 7 8 49mm Male NEMA Plug Bottom Surface...

Страница 4: ...naire type ES NOTA Registre las dimensiones horizontales y verticales de la posici n en UbiHub y la abrazadera para su uso posterior en varias instalaciones del mismo tipo de luminaria 3 3 EN Use a 3...

Страница 5: ...e appropriate clamp insert pair to adjust the clamp size The clamp inserts can be used to fit either a 1 5 IPS Darker Set or 1 25 IPS Lighter Set ES Si el brazo del poste de la luminaria es m s delgad...

Страница 6: ...a doble c mara se env a preinstalada en la unidad UbiHub mediante un cable Levante suavemente la unidad de la caja asegur ndose de que la doble c mara se extraiga tambi n Luego voltee el Ubihub para q...

Страница 7: ...una correa de seguridad entre el UbiHub y el hidroelevador mediante el punto de sujeci n inferior de la unidad WARNING Ubicquia requires the attachment of a safety tether between the UbiHub and lift b...

Страница 8: ...from the luminaire pole When oriented tighten the two side screws EN NOTE CREE fixtures NEMA will need to be locked in ES NOTA Las luminarias CREE NEMA tendr n que fijarse 6 3 EN Line up the bottom ma...

Страница 9: ...6 5 EN Close the clamp around the pole by rotating the clamp latch upward and securing with the swivel locking nut Use the 1 2 deep drive socket to tighten the locking nut to 40 in lbs torque ES Cier...

Страница 10: ...n apretados retire el anclaje de la unidad 6 10 APAI Remove all the protective packaging material from the dual camera Install the dual camera over the mounting clamp vertical adjustment screws by tab...

Страница 11: ...ing clamp based on arm type diameter etc ES El instalador tendr que seleccionar la opci n de conexi n a tierra que va a utilizar en funci n de las normativas y directrices locales as como seleccionar...

Страница 12: ...puerta de acceso posterior del UbiHub 2 EN CAUTION Be sure to follow all applicable safety guidelines when handling SFP modules ES ATENCI N Aseg rese de seguir todas las directrices de seguridad aplic...

Страница 13: ...ura de la junta correspondiente EN B 2 Remove the gasket plug and seat the Ethernet cable into the appropriate gasket opening ES B 2 Retire el tap n de la junta y coloque el cable Ethernet en la abert...

Страница 14: ...N NOTE Compatible PoE cables for accessories must be between 4 0 and 6 0mm in diameter ES NOTA Los cables PoE compatibles para accesorios deben tener un di metro de entre 4 0 y 6 0 mm 8 4 EN If connec...

Страница 15: ...NPT mount into the 1 5 NPS female thread on the bottom of the universal mount ES AP6 Pase el soporte NPT de 1 5 del dispositivo IoT en la rosca hembra NPS de 1 5 de la parte inferior del soport unive...

Страница 16: ...al puerto PoE designado en el panel trasero de UbiHub 9 11 EN Remove the gasket plug and seat the IoT accessory cable into the appropriate gasket opening ES Retire el tap n de la junta y asiente el ca...

Страница 17: ...alaci n del Ubihub ha finalizado Support and Technical Specifications Model AP6 UBH H WI Model APAI UBH H AI FCCID 2AECKUBH01 Contains FCCID XMR201903EG25G Contains FCCID XMR201807EP06A UBIHUB TYPICAL...

Страница 18: ...rence that may cause undesired operation Changes or modifications not expressly approved by Ubicquia Inc could void the user s authority to operate the equipment NOTE This equipment has been tested an...

Страница 19: ...na MIMO 4 en 1 tipo monopolo de circuito impreso flexible optimizada para frecuencias de WiFi 6 Ganancia de la antena Hasta 6dBi Pico de potencia de 2 4GHz 26dBm 5GHz 26dBm 5GHz 26dBm transmisi n puer...

Страница 20: ...es Solo el personal calificado debe instalar mantener o solucionar los problemas de este equipo La instalaci n debe llevarse a cabo siguiendo estrictamente los pasos indicados en este manual incluyend...

Отзывы: