background image

 

10 

 

2.8.

 

Safety requirements 

 
 

            The device complies with Class I of electrical safety. 

Before connecting the chest freezer to the electric power network, 

make sure that  

 

the  network  voltage  corresponds  to  the  value  given  on  the 

device nameplate (+10%, –15%); 

 

the power cord and plug are not damaged. 

The  chest  freezer  must  be  connected  to  a  grounded  power  supply 

socket.  Do  not  connect  the  freezer  to  a  power  supply  with  a  faulty 
overcurrent protection. Check this before starting the installation process. 

Do not use any adapters, additional sockets or extension cords that 

do not match the current load of the device. 

If there are signs of faulty wiring (smell, smoke), disconnect the power 

supply to the device and call a service technician to remedy the fault. 

It  is  forbidden  to  operate  the 

chest freezer: 

if the nominal supply voltage indicated on the nameplate deviates 

by more than + 10% - 15%. 

in case of high level of humidity and dustiness of the environment 

(relative humidity above 75%, when ceiling, walls, floor and other 
objects in the room are covered with moisture); 

 

 

Содержание BEST

Страница 1: ...Operating and Maintenance Manual Chest Freezers...

Страница 2: ...2 3 Placement and installation 6 2 4 Commissioning 7 2 5 Temperature parameters 8 2 6 Tips and remarks 8 2 7 Safety rules 9 2 8 Safety requirements 10 Part 3 Cleaning and servicing 13 3 1 General poin...

Страница 3: ...mmended to ensure proper operation of the equipment Warnings The user should pay attention and act according to the instructions to avoid damage to the equipment and to comply with safety regulations...

Страница 4: ...A Chest freezer User s manual Baskets 4 5 4 5 Casters Package Mechanical lock kit Supply set Unit of measurement STAR AURORA STORM LEGEND KING CYLINDER 50 EXPERT 150 FLAT EXPERT 250 FLAT EXPERT 350 FL...

Страница 5: ...LIND W mm 620 800 1060 1350 1640 620 800 1060 1350 1470 1640 620 800 1060 1350 1470 1640 D mm H mm 875 Diameter 460 The total volume of the compartment L 140 205 300 405 510 54 146 213 311 419 464 528...

Страница 6: ...erature range inside the freezing chamber the chest freezer is equipped with a thermostat The thermostat has the following factory settings minimum temperature in the chest freezer compartment at whic...

Страница 7: ...itates easy movement and installation of your device Install the brake rollers in front of the chest Placement and installation of the chest freezer on site should provide a free area of at least 20 c...

Страница 8: ...ower supply via an extension with branch sockets 2 4 Commissioning Turn on the power of the chest freezer to do this connect the chest power cord to the network A sign of the switching on of the freez...

Страница 9: ...hem or by the flame symbol Before starting up the equipment read carefully the rules of preparation for operation and the rules of operation of a chest freezer as specified in this manual 2 5 Temperat...

Страница 10: ...from the socket and remove everything from the freezer compartment 2 Clean the interior and remove all water Leave the door open until the freezer compartment is completely dry to avoid mildew and odo...

Страница 11: ...nt protection Check this before starting the installation process Do not use any adapters additional sockets or extension cords that do not match the current load of the device If there are signs of f...

Страница 12: ...en performing operations related to servicing the chest freezer and troubleshooting Intended use Do not store bottles or containers in the chest freezer The contents may freeze and containers may expl...

Страница 13: ...circuit avoid any kind of naked flame or potential sources of ignition and thoroughly air the room where the refrigerator is located The volume of the room should be 1 m for every 8 g of refrigerant R...

Страница 14: ...chest is designed in such a way as to minimize the amount of maintenance work By complying the requirements and recommendations in this manual you will ensure the quality and efficiency of this equip...

Страница 15: ...t the ice inside the chest freezer has melted Wipe the inside and outside of the chest freezer and its components with a soft dry cloth If they are too dirty wipe them with a cloth moistened with a de...

Страница 16: ...fan Clean the condenser plates with a stiff brush not metal If possible clean the clogged spaces between condenser plates with a vacuum cleaner or compressed air The condenser should be cleaned carefu...

Страница 17: ...should be switched on again not earlier than in 5 minutes When moving the device from the cold into a warm room let it warm up for at least 2 hours After that the product can be connected to the power...

Страница 18: ...or collecting and recycling used household appliances This marking on the product or literature indicates that the product should not be disposed of with other household waste to prevent possible harm...

Страница 19: ...e power supply connected test and adjustment work must only be carried out by a specialist service technician The system containing the refrigerant must not be de pressurized If necessary this operati...

Страница 20: ...nlight The door is not tightly closed Unplug the chest freezer Call the service technician to diagnose leaks and repair Unplug the chest freezer Clean the air condenser plates Make space around the ch...

Страница 21: ...the chest freezer Call the service technician for repair work The chest freezer makes noise by running The compressor makes noise by running The fan makes noise by running Some parts of the refrigera...

Страница 22: ...odel chest freezer factory number date of sale shall be specified in the chest freezer passport by the manufacturer or the relevant data shall be filled in by the chest freezer s selling company ATTEN...

Страница 23: ...t and observing by the consumer the requirements and operating conditions specified in the operating manual In the absence of a mark or stamp of the sales organization on the tear off sale coupons the...

Страница 24: ...if necessary post warranty maintenance or repair is carried out at the expense of the consumer The service life of the device is terminated in case Introduction of changes in a design of the goods and...

Страница 25: ...facturer Seller Device name in accordance with specification brand Chest Freezer Factory No Device date of manufacture Manufactured according to Manufacturer s quality stamp Surname first name patrony...

Страница 26: ...tamp here Accounting for maintenance and warranty repair work Date Malfunction description Works performed name and type of replaced parts and assemblies Executant s signature Warranty period is exten...

Страница 27: ...ufacturer Seller Device name in accordance with specification brand Chest Freezer Factory No Device date of manufacture Manufactured according to Manufacturer s Quality Control stamp Surname first nam...

Страница 28: ...ure Surname first name patronymic of the responsible person of the Executant Signature Stamp here Signature of the consumer confirming performance of works on warranty repair Signature Date The tear o...

Страница 29: ...ufacturer Seller Device name in accordance with specification brand Chest Freezer Factory No Device date of manufacture Manufactured according to Manufacturer s Quality Control stamp Surname first nam...

Страница 30: ...of the responsible person of the Executant Signature Stamp here Signature of the consumer confirming performance of works on warranty repair Signature Date The tear off counterfoil for warranty repai...

Страница 31: ...ufacturer Seller Device name in accordance with specification brand Chest Freezer Factory No Device date of manufacture Manufactured according to Manufacturer s Quality Control stamp Surname first nam...

Страница 32: ...c of the responsible person of the Executant Signature Stamp here Signature of the consumer confirming performance of works on warranty repair Signature Date The tear off counterfoil for warranty repa...

Страница 33: ...he responsible person of the manufacturer seller signature Stamp here Filled by the Executant Executant Company organization name legal address Date of warranty claim Year month date Surname first nam...

Страница 34: ...com Tel 7 495 505 67 05 Byelorussia E mail service by ubc s com Tel 8 017 237 20 06 Kazakhstan UBC Service Kazakhstan E mail service kz ubc s com Tel 7 727 356 73 76 7 771 775 57 13 Ukraine E mail ser...

Отзывы: