background image

reV: 16i

SMoGHoG

®

SHM Series Models 

15

5.  SERVICE

   Before servicing equipment:

  •  Wear appropriate protective equipment when 

servicing oil mist collector.

  • Disconnect and lockout electrical power to the unit 

and control panel.

5.1  GENERAL MAINTENANCE GUIDELINES

Proper maintenance of the SHM is essential for the unit 

to  provide  excellent  oil  mist  collection  capabilities  and 

long‐term  service.  By  keeping  the  unit  well‐maintained, 

you  will  also  reduce  operating  and  parts  replacement 

costs.  a  scheduled  preventive  maintenance  program, 

specifically  designed  for  the  SHM  and  its  associated 

components,  is  the  best  possible  method  to  ensure  the 

unit stays in proper working order.
refer  to  Section  6  for  troubleshooting  guide  to  correct 

any problems that may occur with your oil mist collection 

unit.  if  the  problem  or  condition  continues,  contact  uaS 

customer service for assistance.

5.2 FILTER SERVICE

automatic  filter  replacement  warnings  should  display  on 

units so equipped.
on unequipped units, when the primary filters reach the 

point  of  not  being  able  to  maintain  proper  unit  function 

they must be replaced.

to  order  filters,  contact  your  uaS  sales  representative. 

identify your filter part number from your sales order, your 

unit nameplate, or the inside cover of this manual.
the aluminum mesh pre-filter can be washed and rinsed 

with a moderately powerful spray from a power-washer or 

hose. this filter can be replaced if contaminants become 

impossible to remove or due to excessive wear.

always wear proper PPe including goggles, dust mask 

and  work  gloves  when  installing  or  replacing  filter 

elements.  oil  accumulated  on  the  filter  elements  can 

result in irritation of the lungs, skin, and / or eyes.

remove used filter elements from the collector and dispose 

of properly, in accordance with governing restrictions. Be 

sure there is no excess oil or residue build-up inside the 

primary filter cabinet. clean or rinse as necessary. inspect 

all  filter  sealing  cam  bars  and  filter  support  parts  for 

unusual signs of wear or failure. checking all gaskets and 

seals is recommended at this time, as well as replacement 

if necessary.
the  surface  of  the  filter  element  can  be  damaged  as  a 

result of improper moving or handling. care must be taken 

to prevent any damage to the filter media. 
inspect  each  filter  element  for  damage  from  shipping, 

storage or handling. do not use damaged elements, they 

may leak or fail prematurely.
review installation procedures for filter elements before 

beginning the installation procedures and accessing the 

oil mist collector. follow the proper lockout, tagout.
numbers in figure 5 coordinate directly with numbering 

below.

 

!

  D A N G E R

    

CAUTION

Task

Maintenance Interval

Check Sump Level, Verify Proper Drainage Weekly (increased frequency may be necessary)
Check For Accumulated Material

Monthly (or when filters are replaced or bin emp�ed)

*Add to this list and adjust the maintenance interval as necessary based on applica�on.

TABLE 4

Maintenance Schedule

Содержание SMOGHOG SHM-11C

Страница 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL ...

Страница 2: ... following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL _________________________________________________________________ SYSTEM ACCESSORIES ______________________________________________________________________________ ___________________...

Страница 3: ...on 8 3 6 1 Installation Procedure for After Filters 8 3 6 1 1 Hold Down 8 3 6 1 2 Enclosed 10 3 7 Drains 10 4 UNIT OPERATION 10 4 1 Start up 10 4 2 System Operation 10 4 2 1 Airflow Adjustment Using Manual Speed Control 10 4 2 2 Airflow Adjustment Using Auto Flow Control 10 4 3 Touchscreen Operation 11 4 3 1 Start Up And Home Screen 11 4 3 2 Standard Format 11 4 3 3 Basic Screens 12 4 3 4 Auto Flo...

Страница 4: ...terials and vapors such as gasoline away from the unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage Operate only in a safe and serviceable condition Operating temperature to the air stream should not exceed 120 F 49 C DANGER WARNING WARNING CAUTION C A U T I O N This is the safety alert symbol This ...

Страница 5: ...re assistance in the installation startup operation maintenance or troubleshooting of your air cleaning equipment contact your local UAS sales representative 2 1 SMOGHOG NOMENCLATURE SMOGHOG oil mist air cleaners are available in a variety of configurations and sizes The model string for each given unit represents the base configuration The model number completely identifies the design and can be ...

Страница 6: ...REV 16I SMOGHOG SHM Series Models 2 FIGURE 1B SHM Equipment Description 61 10113 FIGURE 1A SHM Equipment Description ...

Страница 7: ... the unit in each corner Do not lift the unit by placing lift truck forks through the legs on the underside of the unit Filter Elements Stage 1 Mist Stop fine fiber aluminum mesh Stage 2 Primary coalescer featuring Peach Saturated Depth Coalescing Technology or fiberglass bag Blower Cabinet Most units will have a blower cabinet where the motorized impeller style blower is housed as well as the ele...

Страница 8: ...eering drawings of your specific equipment and options will be provided These and all available documentation for your system should be thoroughly reviewed prior to beginning any installation work This includes the unit and electrical controls Ensure to leave an appropriate amount of room around your unit to allow for maintenance and servicing A minimum of 2 1 2 feet 0 76 m of clearance is recomme...

Страница 9: ...iguration Secure the unit at all four corners using the standard unit feet or extension leg foot pads At least one of the two holes per foot pad on the extension legs should be secured See Figure 1 for reference Ceiling mounted units are suspended by means of 1 2 threaded rods item 1 in Figure 3 which run through weld nuts item 2 in Figure 3 in the top corners of the units Refer to Figure 2 for we...

Страница 10: ...LS ON SHM 11 SUBTRACT 0 5 AMP FROM FLA VALUES ABOVE TABLE 2 Wire Diagrams 3 5 1 ELECTRICAL SUPPLY POWER The main power supply is connected to the SHM unit through a 1 FNPT coupling located on the rear of the unit shown in Figure 1B After feeding wires through the coupling terminations are made on the main bus bar terminal for each phase and frame ground connection The rear electrical panel also co...

Страница 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection ...

Страница 12: ... INTERLOCK DRY CONTACT The customer has the option to control the SHM On Off operation with the oil mist generating equipment or process This will allow the operator to control the SHM with a dry contact off another piece of equipment Refer to the wiring diagrams in the appendix for wiring of this option and to Section 4 for Machine Interlock set up on the touchscreen Wiring will be terminated to ...

Страница 13: ...REV 16I SMOGHOG SHM Series Models 9 61 10115 Figure 5B SHM Filter Removal Installation Figure 5A SHM Filter Removal Installation ...

Страница 14: ... other equipment will need to be engaged as well 7 Verify performance of the system by measuring airflow or evaluating capture at each collection point It is recommended to record baseline performance parameters so the system can be reset in case of an upset condition or system change The recorded data should include the static pressure at each collection hood system amperage draw and filter press...

Страница 15: ...After Filter monitoring or unique screens required for a special application These screens are based on customer order and loaded at the factory Figure 6 4 3 2 Standard Format The icon key Table 3 outlines the various icons that are used on the screen for various reasons and may indicate status or conditions The Home Settings and Information icons are shown at the bottom of most screens and will t...

Страница 16: ...n arrows The second method of airflow adjustment is to touch the box that shows the percentage of the airflow A number pad will be shown in a pop up screen You can enter any number between 20 and 100 This will correspond to the percentage of blower capability The blower is capable of 4 200 RPM at 100 3150 RPM for 75 2100 RPM for 50 and 1050 RPM for 20 These number are approximate and may display s...

Страница 17: ...are not password protected To select one of the items just touch the box with the item you want to make a change too The Locked Settings selection will allow the operator to select options of the system One option is Machine Interlock With Machine Interlock the operator can allow another device CNC machine center plasma table or weld machine to turn the SHM on when the primary device is in operati...

Страница 18: ...ocked Settings group on the Customer settings screen The Auto Flow is an option that is selected at order time and loaded into the SHM at the factory The Auto Flow Settings will allow the unit to maintain a precise operating point based on a desired air volume The operator will select an air volume setting in the airflow set point box using the up down arrows or the selection box If the screen is ...

Страница 19: ...r hose This filter can be replaced if contaminants become impossible to remove or due to excessive wear Always wear proper PPE including goggles dust mask and work gloves when installing or replacing filter elements Oil accumulated on the filter elements can result in irritation of the lungs skin and or eyes Remove used filter elements from the collector and dispose of properly in accordance with ...

Страница 20: ... into place prior to hanging the individual bags loops For units that are two filters deep be sure to push the first filter all way toward the back of the primary filter cabinet until it contacts the stop Reference balloon 1 in Figure 5A The hanging rod is to be inserted through each filter loop and hung from a bracket on each side of the primary filter cabinet Work from the back of the cabinet to...

Страница 21: ...ker Open rear panel on unit and switch breaker if necessary Loose or disconnected wires Inves gate wiring in the rear panel Disconnect is switched to OFF posi on Switch disconnect to ON posi on Improper source power Refer to data plate to verify required input power Screen Displayed Warning Possible Causes Recommended Solu ons Filter Cau on Filter is approaching max life Replace filter s soon Yello...

Страница 22: ...ILTER HEPA 99 97 0 3 μm 5 33 10117 ALUMINUM MESH PRE FILTER 6 33 10128 COALESCING CARTRIDGE FILTER 9 OD PEACH MEDIA 33 LENGTH 3 33 10129 CABINET AFTER FILTER MICROGUARD O M 95 0 3 μm 7 39 10008 0006 CONTROLS PANEL LATCH 10mm HEX 8 39 10058 FLUSH MOUNT FILTER CABINET LATCH NOT SHOWN 42 0168 FILTER CABINET GASKET NOT SHOWN 42 1549 SEALANT NOT SHOWN 20 10413 PRESSURE TRANSDUCER NOT SHOWN 38 10145 BUL...

Страница 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F ...

Страница 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682 ...

Страница 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799 ...

Страница 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695 ...

Страница 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696 ...

Страница 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697 ...

Страница 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802 ...

Страница 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798 ...

Страница 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797 ...

Страница 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796 ...

Страница 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717 ...

Страница 34: ...This page intentionally left blank ...

Страница 35: ...This page intentionally left blank ...

Страница 36: ...ranty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice President of Sales of UAS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORALOR IMPLIED INCLUDINGANYIMPLIED WARRANTYOF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE...

Отзывы: