background image

U.S. 

Solid®•

USS-DBS Models • All Rights Reserved • 

Page 9

U.S. 

Solid® 

 

• 1200 E.55th Unit C, Cleveland, OH, 44103 • www.ussolid.com 

U.S. 

Solid®•

USS-DBS Models • All Rights Reserved • 

Page 2

U.S. 

Solid® 

 

• 1200 E.55th Unit C, Cleveland, OH, 44103 • www.ussolid.com 

Thank you for choosing U.S. Solid’s Analytical Balance. We hope you enjoy your pur-

chase. Please maintain the equipment according to all instructions within the manual.

This product was developed according to CE marking regulations while emphasizing 

aesthetics and safety for the user. It has ISO certific tion, specifically ISO 9001 The 

high quality of the product, coupled with proper user care, should allow you to enjoy 

the product for years.

Improper use of this equipment can cause accidents, including but not limited to: 

electric discharges, circuit breaker malfunctions, fi e, etc. Please read the mainte-

nance section, where this is explained more fully.

FOR BEST RESULTS AND LONGEVITY IN PRODUCT 

EFFICACY, READ THROUGH THIS MANUAL THOROUGHLY 

BEFORE USING THE PRODUCT

Please bear in mind the following:

This manual should be kept with the analytical balance, so it is available to all 

users

Be careful when handling the balance. Avoid any sudden movements when in 

its vicinity. Be sure to not drop the balance, nor drop any heavy/sharp objects 

on it. Keep liquids away from the balance to avoid spills.

Never take apart the balance to try and fix  ourself. This could ruin the entire 

balance, and voids the product warranty. There is also risk of injury when 

disassembling the balance.

To prevent fi e and electrical issues, avoid dusty or overly dry environments. In 

case of electrical issue or fi e, unplug the balance immediately.

During setup, installation, and use, contact your wholesaler with any questions 

that arise.

This equipment is protected under the Warranties and Consumer Good 

Regulation (10/2003)

Overhaul is not covered by the equipment warranty

Changes made to the product by non-certified individuals will  esult in a loss of 

the product warranty

Accessories, including their loss, are not covered by the product warranty, nor 

does the warrant cover piece’s deterioration over the course of time.

Keep your invoice, either for having the right to a warranty, or for asking for 

warranty coverage. Manufacturer reserves the right to modify or improve the 

manual or equipment.

I

I. Getting Started

Troubleshooting Guide

Problem

Cause

Solution

Display not working

No power supply

Plug in the adapter

Display shows 

Object weight below 

minimum threshold, 

taring issues exist, or 

balance is not properly 

calibrated.

Make sure item being 

weighed is at least 10mg. 

Make sure receptacles 

have been tared, and 

the balance has been 

properly calibrated.

Display shows

“  

  “

Item being weighed is 

over maximum allow-

able weight.

Make sure balance is 

properly calibrated, and 

make sure item is below 

maximum allowable 

weight.

Display shows “Err-1”

Power issues with the 

balance.

Machine may have a 

poor power connection. 

Check the power in the 

back, and the outlet. 

Leave machine off  or 

seveeral minutes, unplug 

fully, then reconnect and 

begin again.

Display shows “Err-2”

Unstable weighing con-

ditions.

Recalibrate machine, 

make sure balance is 

level, and make sure 

item being weighed is 

fully stable. 

Содержание USS-DBS

Страница 1: ...e made available to all users of this equipment For best results and for maximum durability of the equipment carefully read and follow all instructions ANALYTICAL BALANCE USS DBS MODELS OPERATING MANUAL ANALYTICAL BALANCES ...

Страница 2: ...ties and other similar canons Judicial surveys Pharmaceutical medicine preparations as well as analysis made in medical or pharmaceutical laboratories Determining the price or total amount in sale price or in pre Instructions on environmental protection At the end of its life cycle please do not dispose of this equip ment by throwing it in the usual garbage Instead hand it over at a collec tion po...

Страница 3: ...ng the balance To prevent fi e and electrical issues avoid dusty or overly dry environments In case of electrical issue or fi e unplug the balance immediately During setup installation and use contact your wholesaler with any questions that arise This equipment is protected under the Warranties and Consumer Good Regulation 10 2003 Overhaul is not covered by the equipment warranty Changes made to t...

Страница 4: ... be plugged into a grounded electrical outlet and the socket should be easily accessible to unplug in case of emergency Never unplug the balance by pulling on the wire do so from the base Never use the balance in a wedged in location such as a shelf Never use other objects such as pens pencils etc to press the buttons on the control panel use only your finger Never place anything on the pan heavie...

Страница 5: ... balance will be unused for an extended period of time disconnect it from the power supply Calibration 3 Remove the weight from the pan 4 The balance will enter weighing mode and will display 0 000g Note Each balance includes the necessary weight to complete external calibration Tare function 1 Put the receptacle on the weighing pan its weight will be displayed 2 Press TARE key and the reading on ...

Страница 6: ...y equipment c Direct sunlight or radiation 4 Do not use the balance anywhere exposed to explosive combustible or corrosive gases 5 Do not use the balance in areas with high humidity or high levels of dust 6 When moving from a cooler to a warmer place the accuracy and reliability of the scale will be influen ed by the moisture condensation inside the balance In order to eliminate this influen e it ...

Отзывы: