Dynamic weighing function

dynamic weighing

put the sample on the pan.

press and hold“PRINT”above 3 seconds,

stop

 

flash

ing

,

 

weighing

 end

,

 

display

will

 

flash

the

 

dynamic

 

weighing

 

start

s. 

shows

 

the

 

final

 

result.

3

press

 

and

 

hold“PRINT”to

 

exit.

Follow

 

4.5

 

setting,

 

set

 

the

 

dynamic

 

weighing

 

to

 

“-dEn-0-”,

 

exit

 

dynamic

 

weighing.

Baud rate setting

press

 

and

 

hold“ON”

 

b

u

tton

 

under

 

weighing

 

interface,

 

the

 

balance

 

enter

s

 

into

 

the

 

main

 

menu

 

mode

release “ON” button until the

 

display

 

shows

 

“SET-F”,

press and hold“PRINT”to enter into baud rate setting, display shows:“F-****”

press and hold“PRINT”to set up baud rate, the display shows:

baud rate 1200

baud rate 2400

baud rate 4800

baud rate 9600

press“TARE”to save the setting and exit.

Print setting

press

 

and

 

hold“ON”button

 

under

 

weighing

 

interface,

 

the

 

balance

 

enter

s

into

 

the

 

main

 

menu

 

mode.

release“ON”button un

til

 the 

display

 

shows

 

“SET-P”,

 

press and hold“PRINT”to enter into print setting, display shows “-Prt-*-”.

press and hold“PRINT”to set up print model, display shows:

interval 0.5s continuously printing

press “PRINT”printing

interval 1s continuously printing

interval 2s continuously printing

interval 3s continuously printing

press“TARE”to save the setting and exit.

4. OPERATION

Содержание 1004

Страница 1: ...Analytical Balance Instruction Manual For questions or concerns e mail service ussolid com visit www ussolid com or call 800 243 5428...

Страница 2: ...calibration weight value setting linearity calibration 4 OPERATION unit conversion piece counting percent weighing density determination dynamic weighing baud rate print setting sensitivity setting fi...

Страница 3: ...quantity of objects Safety Precautions Verify that the AC Adapter input voltage matches the local AC power supply Use the scale only in dry locations For best results use the scale in the specified o...

Страница 4: ...r Capacity Electronic Analytical Balance 0 1mg internal calibration 1004 0 100g 1204 0 120g 2004 0 200g 2204 0 220g 3004 0 300g 3204 0 320g 4204 0 420g 5204 0 520g 0 1mg 2s 30 60 mins g oz ct mg 0 1mg...

Страница 5: ...its Min weighting Repeatability Linearity Interface Pan size Product size N W Power Model Model Model Model 10035 10035N 10055 10055N 10085 10085N 20035X 20035N 20055 20055N 20085 20085N 100g 30g 100g...

Страница 6: ...ours under the power on state to adapt the balance to the new temperature Attention If the number on display is not stable at the first usage it is caused by the temperature difference of the environm...

Страница 7: ...from CAL 0 to CAL 200 and flashes put on the 200g weight for FA2204X model display shows 200 0000 remove the weight and finish the calibration internal calibration weight value setting internal calib...

Страница 8: ...n procedure Unit conversion under the weighing interface press and hold PRINT to change the unit the default unit g oz ct mg other unit is optional piece counting setting press and hold ON button unde...

Страница 9: ...the sample weight the display shows 100 00 If the same contrast is used the second time no re sampling is required Long press PRINT button to exit the percent weighing and return to the weighing mode...

Страница 10: ...splay will show the result of density W1 W2 no display press and hold RPINT to exit density result Follow 4 4 setting set the density weighing to dEn 0 press TARE button to exit density determination...

Страница 11: ...nter into baud rate setting display shows F press and hold PRINT to set up baud rate the display shows baud rate 1200 baud rate 2400 baud rate 4800 baud rate 9600 press TARE to save the setting and ex...

Страница 12: ...ust the sensitivity without consulting the factory Filter level setting press and hold ON button under weighing interface the balance enters into the main menu mode release ON button until the display...

Страница 13: ...face CLOC CLOC CLOC 4 OPERATION RS232 interface Connection Balance 9 pins PC Printer 9 pins RXD Input 2 2 TXD Output 3 3 GND Ground 5 5 Output data format Type or da ta data data data data data data d...

Страница 14: ...ntal Plug in adapter Change the fuse Change the power transformer If problem persists send the balance to the Technical Service for repair Improve the working condition Close the windshield Remove the...

Отзывы: