Electrical Connections

Electrical Grounding Instructions:

A 15 AMP service must be provided for each oven. For 115 

VAC usage, a cord and plug (NEMA #5-15P) is provided but 

connection to the electrical service must be electrically 

grounded in accordance with local codes, or in the absence 

of local codes, with the National electrical code, ANSI/NFPA 

70, or the Canadian electrical Code, CSA C22.2, as applicable. 

This appliance is equipped with a three-prong (grounding) 

plug for your protection against shock hazard and should 

be plugged directly into properly grounded three-prong 

receptacle. DO NOT CUT OR REMOVE THE GROUNDING 

PRONG FROM THIS PLUG.

A wire diagram is affixed to the rear of the unit.

Power Failure

In the event of a power failure, no attempt should be made 

to operate this oven.

Ventilation and Air Supply

Proper ventilation is highly important for good operation. 

There are only two choices for properly venting an oven:  

1

) canopy hood style or 2) direct venting

. The ideal method 

of venting a GAS Convection Oven is through the use of a 

properly designed canopy, which should extend 6” (152 mm), 

beyond all sides of the appliance and 6’6” (1981 mm) from 

the floor.

A strong exhaust fan will create a vacuum in the room. For an 

exhaust system vent to work properly, exhaust and make-up 

air must be balanced properly. For proper air balance contact 

your local H.V.A.C. contractor.

All gas burners and pilots need sufficient air to operate and 

large objects should not be placed in front of this oven, 

which would obstruct the airflow through the front.

INSTALLATION Continued

Installation of Direct Flue

When the installation of a canopy type exhaust hood is 

impossible the oven may be direct vented. Before direct 

venting check your local codes on ventilation, in the absence 

of local codes, refer to the National Fuel Code NFPA 54, ANSI 

Z223.1 (latest revision).

DRAFT DIVERTER

If the unit is to be connected to a direct flue, it is necessary 

that draft diverter be installed to insure proper ventilation.

Direct venting, should be positioned on the main top and 

fastened with sheet metal screws provided. 

DO NOT UNDER SIZE VENT PIPE! This can cause resistance 

to flow and impede good venting. We suggest that if a 

horizontal run must be used it should rise not less than 1/4” 

(6.25mm) for each linear foot of run, and after a total of 180° 

of bends you should increase the size of stove pipe by two 

(2”) inches. The flue should rise 2’ (60cm) to 3’ (91cm) above 

the roof line or 2’ (60mm) to 3’ (91cm) above any portion of a 

building within a horizontal distance of 10 (3 meters) feet.

The following diagram is only one example from the National 

Fuel Gas code Book NFPA 54, ANSI Z223.1,7,5,3:

Содержание Manitowoc Summit series

Страница 1: ...llation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual Summit Series Gas Convection Oven Part Number 1955202...

Страница 2: ......

Страница 3: ...READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE THIS PROD...

Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...ING INSTRUCTIONS 13 Summit 20 Solid State Control with Electromechanical Timer Model SUMG 13 In Off Mode 13 Start Up 13 Fan Speed 13 Lights 13 Cool Down 13 Temperature 13 Timer 14 Summit 45 Electronic...

Страница 6: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 7: ...32 1 2 826 Model Int Dimensions inch mm Ext Dimensions inch mm Ship Wt Ship Dim W H D W H D w motor Lbs kg Cubic Ft SUMG 100 29 736 24 610 24 610 38 965 57 1 2 1461 41 1 4 1048 515 230 64 SUMG 200 29...

Страница 8: ...91 43 1 4 1099 1024 464 84 Models Input Ratings Natural Propane Operating Pressure Electrical Specifications BTU hr kW Equiv Gas Inlet Natural Propane 120V 1Ph 240V 1Ph Single Deck 60 000 17 6 1 3 4 N...

Страница 9: ...6 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use With Gas Fuel ANSI Z21 41 CSA 6 9 and adequate means must be provided to limit the movement of the...

Страница 10: ...ne gas B If it is a new installation have gas authorities check meter size and piping to assure that the unit is supplied with sufficient amount of gas pressure required to operate the unit C If it is...

Страница 11: ...om For an exhaust system vent to work properly exhaust and make up air must be balanced properly For proper air balance contact your local H V A C contractor All gas burners and pilots need sufficient...

Страница 12: ...and correct any leaks and recheck Replace all service panels and covers before operation NOTE All electronic ignition systems are supplied with a redundant gas valve Therefore the unit is not supplie...

Страница 13: ...150 RPM The fan speed is controlled by the left rocker switch marked high and low Lights The oven lights are activated by pressing the light switch on the control panel This is a momentary switch and...

Страница 14: ...d low fan speed The display will indicate LO when the oven is below the set temperature When the oven cavity reaches the set temperature and is ready for operation the display will indicate LOAD NOTE...

Страница 15: ...ressing the COOL DOWN key again will turn the LED off and stop this mode Pressing the ON OFF key will also cancel Cool down Cool Down is not active during a cook When the ON OFF switch is pressed to t...

Страница 16: ...prompt To cancel a timing cycle OPERATING INSTRUCTIONS Continued in progress press and hold the START CANCEL key for 3 seconds Core Probe Operation The Core Probe option 45 Controller Only is only act...

Страница 17: ...be removed from the oven as soon as possible to avoid over cooking 9 Center pans on racks and load each shelf evenly to allow for proper air circulation within the cavity 10 When baking weigh or measu...

Страница 18: ...4 min Apple Turnovers 350 25 min Cream Puffs 300 25 min Sugar Cookies 325 12 min Chocolate Chip cookies 375 8 min Apple Pie Fresh 375 25 min Blueberry Pie Fresh 350 30 min Blueberry Pie Frozen 300 50...

Страница 19: ...Medium Rare Medium 8 2 5 3 5 1 5 2 1 25 1 5 9 2 75 3 75 1 75 2 25 1 25 1 75 10 3 4 25 2 2 5 1 5 1 75 11 3 25 4 5 2 2 75 1 5 1 75 12 3 5 5 2 25 3 1 5 2 13 3 75 5 2 5 3 25 1 5 2 25 14 4 5 75 2 5 3 5 1 7...

Страница 20: ...one hour at 375 F 191 C before you begin your normal cooking operation After cooling wipe the interior including the racks with a clean damp cloth Exterior Cleaning Establish a regular schedule Any sp...

Страница 21: ...ing at peak performance CLEANING AND MAINTENANCE Continued Motor Care The motor on your convection oven is maintenance free since it is constructed with self lubricating sealed ball bearings It is des...

Страница 22: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 23: ......

Страница 24: ...ervice that meets your operational needs from one restaurant to multiple locations StarCare Warranty lifetime service certified OEM parts global parts inventory performance audited ExtraCare CareCode...

Страница 25: ...ice that meets your operational needs from one restaurant to multiple locations StarCare Warranty lifetime service certifi ed OEM parts global parts inventory performance audited ExtraCare CareCode 24...

Страница 26: ......

Страница 27: ...CETTE PAGE EST LAISS E BLANCHE INTENTIONNELLEMENT...

Страница 28: ...nnement optimal ENTRETIEN ET NETTOYAGE suite Entretien du moteur Le moteur de votre four convection est sans entretien puisqu il est fabriqu l aide de roulements billes scell s lubrifi s Il est con u...

Страница 29: ...est neuf faites fonctionner celui ci pour une heure 375 F 191 C avant de commencer votre fonctionnement de cuisson normal Apr s que celui ci est refroidi nettoyez l int rieur incluant les grilles l a...

Страница 30: ...ture 300 F Saignant point Saignant point Saignant point 8 2 5 3 5 1 5 2 1 25 1 5 9 2 75 3 75 1 75 2 25 1 25 1 75 10 3 4 25 2 2 5 1 5 1 75 11 3 25 4 5 2 2 75 1 5 1 75 12 3 5 5 2 25 3 1 5 2 13 3 75 5 2...

Страница 31: ...Choux la cr me 300 25 min Biscuits au sucre 325 12 min Biscuits aux brisures de chocolat 375 8 min Tarte aux pommes fra che 375 25 min Tarte aux bleuets fra che 350 30 min Tarte aux bleuets congel 30...

Страница 32: ...que possible le four doit tre retir du four pour viter que le produit nn soit trop cuit 9 Centrez les moules sur les grilles et chargez chaque tage uniform ment afi n de permettre une circulation ad q...

Страница 33: ...ant la touche D MARRAGE ARR T pour trois secondes Fonctionnement de la sonde centrale L option de la sonde centrale contr leur 45 seulement est activ e seulement si celle ci est branch e au connecteur...

Страница 34: ...onction de refroidissement La fonction de refroidissement n est pas activ e lors de la cuisson Lorsque l interrupteur ALLUMER TENDRE est enfonc ceci arr tera le four et si le four est plus de 200 F 93...

Страница 35: ...diquera BAS lorsque la temp rature du four est inf rieure la temp rature r gl e Lorsque la cavit du four atteint la temp rature r gl e et que celui ci est pr t l utilisation le message CHARGE s affi c...

Страница 36: ...ateur est contr l e par l interrupteur basculant situ gauche identifi par haut et bas Voyants Les voyants du four sont activ es en appuyant sur l interrupteur de lampe situ sur le panneau de contr le...

Страница 37: ...fuite et proc dez un nouveau test Replacez tous panneaux de services et couvercles avant de faire fonctionner l appareil REMARQUE Tous les syst mes d allumage lectronique sont aliment s par la vanne d...

Страница 38: ...n dans la pi ce Pour qu un syst me de ventilation aspirant fonctionne ad quatement le ventilateur aspirant ainsi que l air d appoint doivent tre correctement quilibr Pour un air d appoint quilibr cons...

Страница 39: ...tation de gaz propane seulement B Pour une nouvelle installation faites v rifi er la taille du compteur ainsi que la tuyauterie par un fournisseur de gaz autoris pour vous s assurez que l appareil est...

Страница 40: ...norme pour les appareils d montage rapide utilisation avec carburant gaz ANSI Z21 41 CSA 6 9 ainsi que les moyens ad quats pour limiter le mouvement de l appareil sans d ranger le connecteur ainsi qu...

Страница 41: ...lectriques BTU hr quival kW Entr e de gaz Naturel Propane 120 V 1 Ph 240 V 1 Ph Four simple 60 000 17 6 1 3 4 pouce 1 90 cm PTN 4 5 pouces 12 70 cm WC 11 millibars 10 pouces 25 40 cm WC 25 millibars...

Страница 42: ...1 2 po 1130mm Non emball 32 1 2 po 826mm Mod le Int rieur Dimensions po mm Ext rieur Dimensions po mm Poids d exp dition Volume d exp dition L H P L H D w moteur livre kilogram Pied cube SUMG 100 29 7...

Страница 43: ...CETTE PAGE EST LAISS E BLANCHE INTENTIONNELLEMENT...

Страница 44: ...vec minuterie lectrom canique Summit 20 MOD LE SUMG 13 En mode arr t 13 D marrage 13 Vitesse du ventilateur 13 Voyants 13 Refroidissement 13 Temp rature 13 Minuterie 14 Contr le lectronique muni de la...

Страница 45: ...CETTE PAGE EST LAISS E BLANCHE INTENTIONNELLEMENT...

Страница 46: ...ER LA MORT VEUILLEZ LIRE LES DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN S RIEUSEMENT AVANT DE PROC DER L INSTALLATION OU L ENTRETIEN DE CET QUIPEMENT VEUILLEZ LIRE TOUTES LES SECTIONS DE C...

Страница 47: ......

Страница 48: ...est mis jour au fur et mesure que de nouvelles informations sont disponibles et que de nouveaux mod les sont commercialis s Pour obtenir la derni re mise jour du manuel visitez notre site Web Summit...

Отзывы: