Part # 3052000 (09/16/09)
Page 17
COMMISSIONING Continued
Fig 5
INJECTOR
LOCATION
OPENING
CUISINE BURNER SHUTTER
SKSHUT
Figure 6
Injector Location
Fixing Screw
Required Length
of Opening
Aeration
Shutter
Opening
Solid Top/Griddle
1. Check to make sure that the air shutter is set to give the
required opening.
2. Adjust as necessary
(See Figure 6)
Front Fired Solid Top,
1. Check that the aeration shutter is set to provide the
required opening.
Broiler Burner
1. Check that the aeration shutter is set to provide the
requested opening.
Thermostat Bypass Adjustment – Oven
Figure 7
R
O
B
E
R T
S
H
A
W
MODEL
FDO
1/2 PSI
By-Pass
Flame Adjuster
Indicator
Mark
Calibration
Lock Screw
Calibration
Plate
Dial
Stop
With reference to Figure 7, the Robertshaw FDO snap-
throttle thermostat requires a bypass adjustment. To adjust
the bypass, follow this procedure.
1. Turn the oven temperature control dial to 200°F (93° C)
then allow the oven to heat for 3 minutes.
2. Turn the oven control dial to the OFF position, then
slowly turn the oven temperature control dial counter-
clockwise until an audible click is heard.
3. Making sure not to disturb the oven temperature control
dial, turn the bypass flame adjusting screw and adjust
the bypass flame to the Lowest Possible Stable flame
covering the Entire Ported Area of the Burner. Turn
the adjusting screw counter-clockwise to increase or
clockwise to decease the size of the bypass flame.
NOTE: For calibration please refer to Thermostat Calibration
in the Service Section.