background image

4

VACUUM SWITCH (1):

This switch will illuminate when the vacuum motors are on.  The vacuum motors run off of cord #1.

HEAT SWITCH (2):

The heat switch will illuminate when it is activated and will turn the heater on.

CIRCUIT LOCATOR (3):

When this light is on, it indicates that cord #2 is on a separate line from cord #1.  Cord #2 supplies

voltage to the heater allowing it to heat to the proper temperature range.

HEAT LIGHT (4):

When this light is on, it indicates that heat exchanger is actively heating.  This light will go out when the

heater reaches temperature. As you clean, it will be on most of the time.

PUMP CONTROL (5):

This switch turns the pump ON/OFF. The pump runs off of cord #1.  The pump is an “on demand” style

pump, so it will only run when you are spraying.

CAUTION: WHEN THE HEAT SWITCH IS ON, THE CIRCUIT BREAKER IN THE WALL CAN TRIP IF

BOTH CORDS ARE ON THE SAME CIRCUIT.

SWITCH PLATE

1

2

4

3

SOLUS-150

5

Содержание SOLUS-150

Страница 1: ...mer when foaming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine freeze Do not use outdoors 3 Do...

Страница 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Страница 3: ...Once a month minimum run a flushing compound through the machine to break up any mineral or chemical build up that may have formed U S Products X 1500 is recommended The vacuum motor pump motor and th...

Страница 4: ...allowing it to heat to the proper temperature range HEAT LIGHT 4 When this light is on it indicates that heat exchanger is actively heating This light will go out when the heater reaches temperature A...

Страница 5: ...ning 4 Refill and empty the tanks as necessary 5 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Sto...

Страница 6: ...38 32 33 39 42 41 40 49 58 43 44 45 46 53 48 52 51 05 20 2008 1 3 5 24 12 16 18 15 14 19 23 19 13 17 9 7 55 8A 26 34 59 35 37 36 50 22 8 Pump to Heater Hose Heater to Outlet Hose 10 11 2 4 20 27 30 5...

Страница 7: ...k 26 909A Latch strike 27 1126 Hose barb 90 3 8 hose 28 925 Hose 3 8 ID X 18 29 166 Hose clamp 30 2007 Pump 100 psi 31 108A Hose barb elbow 32 FP225 Control PCB Vacuum Motor 33 1476 Strap 17 34 207A F...

Страница 8: ...ugh the pump If so the problem is not in the pump Debris is plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged Ball...

Отзывы: