SPECIFICATIONS and FEATURES:

Output volume:

Maximum Output:

Timer:

Production Method:

Air Flow:

Deminsions:

Weight:

Warranty:

Variable
2.2 gm/HR; 6.6 ppm
Digital, 00:00 to 29:59 hours
Patented, high-density and stainless steel electrodes
100 CFM
8”H X 8”W X 22”L
12-1/2 lbs

3 year; lifetime on electrodes *

TROUBLE SHOOTING:

ALWAYS UNPLUG THE MACHINE BEFORE
YOU DO ANY INTERNAL TROUBLESHOOTING

CAUTION:

NOTE: if the air intake filter is dirty or missing warranty is voided.

IF THIS OCCURS

CHECK THIS

NO POWER

Look at the power cord, to make sure it is plugged in.
Check the outlet, to make sure it has power in it.
Look at the circuit breaker on the bottom of the machine, to make sure it has not
tripped.
Check the internal safety switch to make sure it is ‘activated’ when the bottom cover
is on.

TIMER DOES

NOT WORK

The digital display has segments missing from some numbers.
The timer     or      buttons do not change the time display.
The time display does not change as time passes.

<

<

THE % of  OZONE

DOES NOT WORK

The % button does not work.  The amount of ozoneoutput does not change.
The % button does work, but one (or more) of the red LEDs is not lighting.

*

 

A dirty or missing filter at the air intake voids the warranty

Rugged construction means reliability

No maintainence of plates or UV tubes

Over-load protection

Содержание OASIS-PLUS

Страница 1: ...er Limited exposure can cause irritation to eyes throat and nose and it may cause nausea Do not re inhabit a treated area until it has been well ventilated Prolonged exposure can also affect certain o...

Страница 2: ...it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Keep the cord away from heated surfaces To unplug grasp...

Страница 3: ...inutes per second Hold the button for longer than 3 seconds and the time setting will change in 20 minutes increments The maximum time setting is 29 59 hours After reaching the maximum time the timer...

Страница 4: ...cal contamination and odor in areas up to 40 000 FT3 Use the following times as a guideline Hotel Motel Room 20 60 Minutes Automobiles 20 30 Minutes Fire Flood Restoration 12 72 Hours For Automobiles...

Страница 5: ...r FP242 7A Electrode Assembly FP241 8 Hose Clamp 198 9 Fan 2014 10 Lock nut 324 10A Bolt 8 32 X 2 1 2 323 11 Fan cover filter 2015A 12 Filter only 2015B 13 Screw 4 40 X 5 8 S S 328 14 Bracket for safe...

Страница 6: ...D SCREW 16 GREEN 14 GA 16 1 2 GREEN 18 GA 9 65 12 12 GREEN 14 GA 9 1 4 146 334 320 320 3 PAIR 6 WIRES 147 64 BLACK 16 GA WASHER 1096 LOCKNUT 358 HIGH VOLTAGE ELECTRODE CHAMBER RING CONNECTOR 334 16 1...

Страница 7: ...ugged in Check the outlet to make sure it has power in it Look at the circuit breaker on the bottom of the machine to make sure it has not tripped Check the internal safety switch to make sure it is a...

Страница 8: ...8 NOTES OASIS PLUS 120V 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com...

Отзывы: