background image

1200 PSI HIGH PRESSURE WASHER

1

Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness.

Make sure the hoses are in good condition and the spray nozzle(s) is tight.

2. When not using the auto-dump feature, just make sure the brass cap is screwed tightly on the hose

connector fitting on the rear of the machine.  If you choose to use the auto-dump, connect the dump

hose to brass hose fitting on the back of the machine, and place the open end of the hose in a drain.

Make sure the drain hose (recovery tank) is closed, and the lid is tight on the recovery tank.

REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGES.

3. If you choose to use the auto-fill feature, connect the fill hose to the auto-fill valve (located over the

solution tank fill hole).  Place your gallon of chemical in the chemical basket on the recovery tank lid,

and put the weighted foot valve into the gallon. Turn on the water source, and allow the tank to fill with

solution.  When using the auto-fill system, the auto-fill valve will automatically turn on and turn off as

the tank empties and then fills.  NOTE: If you are not going to use the auto-fill system, just fill the

tank with water and cleaning chemical. Follow chemical directions regarding dilution and mixing. Do not

use harsh chemicals; they may damage seals in pumps and valves, and cause the pump to wear

prematurely.  NOTE: Never use water with a temperature exceeding 130 °F / 54 °C.

REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGES.

4. Pre-spray the area to be cleaned, with a pump-up sprayer, while the tank is filling.  Follow chemical

directions.

5. Connect the solution hose (from the reel) to the 1200 PSI Quick Disconnect on the front of the tank,

below the switch plate.

6. Plug in the two power cords.  Do not connect both cords to the same outlet. The green, ‘separate

circuit’ locator light (1) on the switch plate should light up.  If the locator light does not come on, check

the circuit breaker box in the wall, and/or try different outlets until it does turn on.  Although all systems

in the machine may work correctly if you are not on two circuits, a circuit breaker in a wall panel may

trip. If you make sure the green light is turned on, you will prevent tripped circuit breakers. Turn on the

1200 PSI pump by placing the HIGH PRESSURE/HEAT selection switch (2) in the UP position, to select

the 1200 PSI Pump.  NOTE: both the 1200 PSI pump and the heat can not operate at the same

time.  NOTE: this switch (2) is off when it is set to the middle position and neither the 1200 PSI pump

nor the heater is selected.

8. Prime the 1200 psi pump using the ‘power prime’ system: turn on both the pump and the vacuum

(3), cover the hole in the vacuum hose barb on the top of the machine with your hand, then depress

the Power Prime Pedal (located on the back of the machine).  This will pull trapped air through the
pump a

nd into the recovery tank, priming the pump.  You should notice a change in the ‘tone’ of the

pump (smoother, with less rattle), and the water being pulled into the recovery tank will change from a

white, sputtering flow to a clear, solid stream. NOTE: priming requires a full Holding tank, and it may

take between 20 to 90 seconds. Once the pump has primed, release the Power Prime Pedal, and turn

both the pump and the vacuum off. Momentarily depress the Power Prime pedal again to release any

built-up back pressure.  Proceed to Step 9.

OPERATION

REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE

CAUTION:  Use care when handling hazardous chemicals.
CAUTION:  Never leave the machine running when you are not
actively using it.
DANGER:  Do NOT use solvents, or any chemicals that may be
flammable, explosive, or combustible.

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание KING COBRA 1200 PRO

Страница 1: ...spot 3 Before each use remove the spray tool from the hose and check to make sure the spray nozzle is securely tightened to the spray tool A loose nozzle could fly off during use 4 If a leak occurs a...

Страница 2: ...by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug gras...

Страница 3: ...nce a month minimum run a flushing compound through the machine to break up any mineral or chemical build up that may have formed U S Products X 1500 is recommended The vacuum motor pump motors and th...

Страница 4: ...ection Auto fill Basket Wheel Recovery Dump Hose Castor Switches Auto Dump Pump Power Cord Recepticle Power Prime Pedal Base Compartment Vac Tank Latch Chemical Pick up hose Solution Tank 1200 PSI Qui...

Страница 5: ...not connect both cords to the same outlet The green separate circuit locator light 1 on the switch plate should light up If the locator light does not come on check the circuit breaker box in the wal...

Страница 6: ...and cleaning tools for cleanliness and completeness Make sure the recovery tank drain hose is closed and the lid is tight on the recovery tank Make sure the hoses are in good condition and the spray n...

Страница 7: ...ure regulator cap lower front while you are spraying and watching the 500 psi pressure gauge NOTE the gauge will only read pressure while you are spraying 10 Spray for a few seconds to fill the lines...

Страница 8: ...The autofill float will automatically shut off the flow of incoming water when the tank is nearly full and it will allow the valve to open again once the water level has dropped to a predetermined lev...

Страница 9: ...hose into a drain Turn the dump pump switch ON switch is located on the switch panel on the top of the machine NOTE the dump pump will only run when the tank is full enough to activate the float swit...

Страница 10: ...38 31 37 41 46 49 49 39 28 28 36 6 KC 1200 PRO 120V 11 2 2006 110 110A 82 72 83 79 69 68 74 75 104 101 102 83 105 106 107 108 111 78 79 121 122 123 128 127 124 138 139 140 142 143 66 112 80 99 to out...

Страница 11: ...4 FP508 1200psipump motor complete 105 1062 Recepticle power cord 106 957 Pump auto dump 107 1324 HoseConnector dumppumpout 108 1325 Elbow auto dumpin 110 4405A Relay 20Amp 110A 2025 Heat sink plate 1...

Страница 12: ...ent fully adjustable 0 500 psi Positive displacement 1200 psi 2 2 gpm 1500 Watts 16 gallon solution tank 14 gallon recovery tank two detachable 12 3 hospital grade plugs 39 H X 21 W X 36 L 5 5 gpm wit...

Отзывы: