background image

Recovery Tank

Access Lid

Recovery Hose

Connection Point

Latches

Castor

Wheel

Drain Gate

& Pump Out

Hose Connection

(on rear)

SET-UP:

Connect the vacuum/recovery hose to the vacuum inlet hose barb on

the front of the recovery tank.  Connect one or two of the dump hoses

to the hose fitting on the rear of the machine.  Put the lid on the re-

covery tank.  Plug the machine into a grounded outlet.

VACUUM OPERATION:

A switch is provided for each vacuum motor.  The machine can

operate with either one or both vacuum motors running.  If only one

vacuum is needed, use VAC 1;  a one-way valve allows VAC 1 to

create a suction by preventing air from being pulled through VAC 2,

when VAC 2 is not running.

VACUUM SHUT-OFF:

When the recovery tank is full, the float system will shut off power to

the vacuum motor(s) to prevent water from entering the motor(s).

The float may not work properly if it is extremely dirty or if there is

foam in the tank.  Once the tank is emptied sufficiently, the vacuums

will come back on automatically.

PUMP  OPERATION:

Always be sure to uncap the pump-out fitting and connect the dump

hose before turning the pumps on.  Failure to do so may result in

blown hoses or loose fittings; water will damage motors and switches.

The two diaphram pumps on your Flood Pumper work together.

When you turn the pump switch on, both pumps will run, and they will

continue to run until you turn them off.  Do not let the pumps run dry

for extended periods of time.

Содержание Flood Pumper

Страница 1: ...Always be sure to remove the cap on the pump out fitting and connect the dump hose before turning the pump s on 3 Keep all filters clean Do not operate the machine if the filters are clogged 4 Keep ma...

Страница 2: ...the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine...

Страница 3: ...ne or parts MAINTENANCE Prior to each job inspect the recovery tank filters the in line filters the float and the drain gate to make sure every thing is clean and able to function properly After each...

Страница 4: ...ir from being pulled through VAC 2 when VAC 2 is not running VACUUM SHUT OFF When the recovery tank is full the float system will shut off power to the vacuum motor s to prevent water from entering th...

Страница 5: ......

Страница 6: ...MA 6 Manifold Black 34 2079 Hose 3 4 Polywire 11 34A 380 Hose Clamp 35 378 Hose Barb 3 4 x 1 2 m p t Brass 36 184 Cord Retainer 36A 495A Power Cord Yellow 25 37 237 Cap with Chain and Hose Connection...

Страница 7: ...SCHARGE RATE FILTER SYSTEM WEIGHT One 25 ft 12 gauge 3 wire with hospital grade plug 13 amps total 12 gallon 2 X 25 Two 2 stage vacuum motors 90 inches 200 Electronic Float Auto ON OFF Two diaphram pu...

Страница 8: ...208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com NOTES FLOOD PUMPER 120V...

Отзывы: