1
Inspect the machine, hoses, and cleaning tools for cleanliness and completeness.
2
Fill the solution tank with water. Using warm water may be a benefit in cleaning effectiveness,
but do not use hot water (above 130
°
F / 54
°
C) in the tank.
3
Plug in the power cords. Do not connect both cords to the same outlet; the green circuit
locator light (1) on the switch plate should light up. If the locator light does not come on, try
different outlets until it does. If you are certain the cords are on separate circuits, turn the
bypass switch ON (2). This will allow the heater to turn on.
CAUTION: using the bypass switch when the cords are on the same circuit may cause the
breaker in the wall to trip. NOTE: the red light will turn on only when the heat exchanger is
actively heating.
4
Connect the priming hose to the machine, turn the pump switch ON (6) and prime the air out of
the pump by allowing the water to flow unrestricted. When the water is clear (no air in it) turn the
pump off and remove the priming hose. NOTE: if priming is difficult, place the open end of the
priming hose into the vacuum inlet hose barb, and turn the vacuum on (4). Use your hand to
OPERATION
CIRCUIT LOCATOR LIGHT INDICATES TWO
CIRCUITS. HEATER WILL AUTOMATICALLY
TURN ON.
BYPASS SWITCH.
TURNS THE HEATER
ON WHEN GREEN
LIGHT IS NOT ON
1
2
3
VACUUM
ON/OFF SWITCH
4
RED LIGHT INDICATES
HEATER IS HEATING
PUMP
ON/OFF
SWITCH
6
SELECT CARPET
OR UPHOLSTERY
5
Содержание COBRA PLUS-310