A-12 / ENGLISH
A-12
- FORM NO. 56091020 - PEX 200, 500
AFTER USING THE MACHINE
1
To empty the solution tank, open Solution Tank Fill Opening
(2)
and vacuum out all unused solution into the recovery tank using the
vacuum hose. Rinse the tank with clean water.
2
Turn all the Power Switches
(A, B, C & E)
to OFF (O). Unplug the Power Cords
(20)
. Coil the cords and secure them to the rear of the
machine using the four Cord Retainer Straps
(17)
.
3
To empty the recovery tank, loosen the Velcro strap retaining the Recovery Tank Drain Hose
(4)
into its side storage location. Direct
the hose to a designated waste water “DISPOSAL SITE” and remove the plug (hold the end of the hose above the water level in the tank to avoid
sudden, uncontrolled
fl
ow of waste water). Rinse the tank with clean water. Inspect the drain hose; replace if kinked or damaged.
4
Disconnect the solution and vacuum hoses from the machine, at the Solution Hose Quick Disconnect
(1)
and Vacuum Hose Barb
(3)
respectively. Flush the vacuum hose with warm water to wash any debris out of the vacuum hose and cleaning tool. Inspect them for damage.
Fold down the Hose Hangers
(21)
and the hoses can be wrapped around the machine for storage. Set the wand on the Wand Retainer Bracket
(19)
and secure to the back of the machine at the Wand Storage Clip
(13)
.
5
Wipe the machine with a damp cloth. Do not use abrasive chemicals or solvents.
6
Perform any required maintenance before storage.
MAINTENANCE SCHEDULE
MAINTENANCE ITEM
Daily
Weekly
Yearly
Check / Clean Tanks & Hoses
•
Check / Clean Recovery Tank Shut-Off Float
•
Clean Extraction Wand/Tool
•
Inspect & Clean Solution Filter
•
*
Check Carbon Brushes
•
* Have a US Products service technician check the vacuum motor carbon brushes once a year or after 300 operating hours. Check the pump
motor carbon brushes every 500 hours or once a year.
IMPORTANT!
Motor damage resulting from failure to service the carbon brushes is not covered under warranty. See the Limited
Warranty Statement.
7
Store the machine indoors in a clean, dry place with the recovery tank lid open. Keep from freezing.
POWER CORD MAINTENANCE
Once a week (or more often if necessary), check the power cords for cracked or damaged insulation, exposed wires in the cord or plug, and
damaged or missing ground pin. Repair or replace damaged cord or plug
immediately
.
Содержание 56113000
Страница 11: ...ENGLISH A 11 FORM NO 56091020 PEX 200 500 A 11 OPERATING THE MACHINE...
Страница 23: ...ESPA OL B 11 FORM NO 56091020 PEX 200 500 B 11 MANEJO DE LA M QUINA...
Страница 35: ...FRAN AIS C 11 FORM NO 56091020 PEX 200 500 C 11 UTILISATION DE LA MACHINE...
Страница 38: ......
Страница 40: ...40 PEX 200 500 500 CSA 56091020 1 11 PARTS LIST DECAL SYSTEM 1 2 3 4 5 6 revised 7 2012...