![U.S. Divers Impulse Скачать руководство пользователя страница 18](http://html2.mh-extra.com/html/u-s-divers/impulse/impulse_service-and-repair-manual_3089293018.webp)
16
Impulse Second Stage Service & Repair Manual
© 1997 U.S. Divers Co., Inc.
Table 4
Torque Specifications
PART NUMBER
DESCRIPTION / KEY NUMBER
TORQUE
1005-35
LP Hose Female Fitting / 8
40 (
±
3) inch-lbs
1078-03
Hex Nut / 11
50 (
±
5) inch-lbs
Table 5
Test Bench Specifications
TEST
CONDITION
ACCEPTABLE RANGE
Leak test
Inlet 2,500-3,000 (
±
100) psi
Knob turned full out
CCW
Slight leak
Knob turned in
CW
1/2 - 3/4 t
ur
n N
one
Intermediate pressure
Inlet 2,500-3,000 (
±
100) psi
140 (
±
5) psi
Intermediate pressure creep Inlet 2,500-3,000 (
±
100) psi
5 psi max between 5 to 15 seconds
after cycling regulator (purge)
Opening effort
Inlet 2,500-3,000 (
±
100) psi,
intermediate pressure 140 (
±
5) psi
Knob turned in
CW
1/2 - 3/4 t
ur
n +
.6 to +1.0 inch H
2
0
(no leak)
Knob turned full in
CW
+2.0 to +2.7 inch H
2
0
Flow effort
Intermediate pressure 140 (
±
5) psi
+6 inches H
2
0 (maximum)
at 15 SCFM
Purge flow
Intermediate pressure 140 (
±
5) psi
5.0 SCFM flow rate (minimum)