U.S. Divers Impulse Скачать руководство пользователя страница 15

Impulse Second Stage Service & Repair Manual

13

© 1997 U.S. Divers Co., Inc.

2.

Observe any bubbles arising from the submerged regulator
over a one minute period.  The recommended time is necessary
due to slower bubble formation that occurs in smaller leaks.
Bubbles indicate a leak, which requires that the system must
be disassembled at the source to check sealing surfaces, assem-
bly sequence and component positioning in order to correct the
problem(s).

NOTE

:  Extremely small leaks may be better detected by

applying a soap solution or Snoop™ to the leak area.  Bubble
streams will indicate the source of the leak.  Before disas-
sembling to correct any leaks, rinse the entire regulator
thoroughly with fresh water and blow out all residual moisture
with filtered, low-pressure (50 psi) air.  Disassemble and
remedy the problem, referring to Table 1 - Troubleshooting.

SUBJECTIVE BREATHING TEST

1.

While the regulator is connected to a cylinder containing 3,000
psi and pressurized, turn the second stage adjustment knob
completely out counterclockwise to the full positive position,
and verify that a slight leak of airflow is present.

2.

Slowly turn the adjustment knob in clockwise to verify that the
airflow stops between 

1/2 - 3/4 t

urn.

3.

Turn the adjustment knob completely in clockwise to the full
negative position, and depress the second stage purge to ensure
that an adequate volume of air needed to clear the second stage
flows through the mouthpiece..

4.

Turn the adjustment knob back to 

1/2 - 3/4 t

urn negative, and

breathe from the second stage.  A properly serviced and ad-
justed regulator should deliver air upon deep inhalation with-
out excessive inhalation effort, freeflow, or “fluttering” of the
second-stage diaphragm.  When exhaling, there should be no
fluttering or sticking of the exhalation valve.  If any of these
problems occur, refer to Table 1 - Troubleshooting.

This concludes annual service procedures for the Impulse

Содержание Impulse

Страница 1: ...Impulse SecondStageRegulator P O Box 25018 3323 W Warner Ave Santa Ana CA 92799 5018 Copyright 1997 U S Divers Co Inc Doc No 1078 56 Authorized Aqua Lung Dealer SERVICE REPAIR MANUAL...

Страница 2: ...Testing Procedures 10 Second Stage Air Flow Test 12 Second Stage Opening Effort Test 12 Second Stage Purge Flow Test 12 External Leak Test 12 Subjective Breathing Test 13 Table 1 Troubleshooting Guide...

Страница 3: ...es outlined in the Impulse Owner s Manual GENERAL GUIDELINES 1 In order to correctly perform the procedures outlined in this manual it is important to follow each step exactly in the order given Read...

Страница 4: ...tage with a stable intermediate pressure of 140 psi 5 with no open ports or hoses 2 Connect the first stage to a cylinder that is filled with 3 000 psi and open the cylinder valve to pressurize the re...

Страница 5: ...mouthpiece 15 from the box bottom Inspect the mouth piece to ensure it is free of any tears or cuts that may cause leakage of water into the second stage or other discomfort Discard or set the mouthp...

Страница 6: ...the washer 29 for any signs of wear or damage and discard if found 14 Remove and discard both O rings 30 31 and set the adjust ment knob aside to be cleaned separately in a mild acid bath white vineg...

Страница 7: ...the polished sealing surface If damage is found discard the crown and do not attempt to reuse If it is in reusable condition set it aside on a soft surface to prevent damage to the sealing edge 25 Us...

Страница 8: ...place while it is being positioned inside the box bottom 4 While holding the vane switch in place set the box bottom on a flat surface with the open side facing down and the switch at 12 o clock Guide...

Страница 9: ...er the stem of the poppet assembly so that it is seated securely at the base 11 Stand the valve body vertically with the male threaded inlet end facing down and positioned so that the lever faces di r...

Страница 10: ...til it stops This will hold the pin securely in place to prevent it from falling out while installing the valve module into the box bottom 19 Lay the valve module assembly horizontally so that the adj...

Страница 11: ...ment knob can be completely unscrewed and removed from the valve body do not attempt to assemble any further Disassemble as needed to cor rectly install the retaining pin Severe injury or death may ot...

Страница 12: ...Thread the male fitting of the IP hose into the preferred low pressure port of the first stage and apply a torque wrench with 11 16 crow foot to tighten to 40 inch pounds 2 2 Connect an intermediate...

Страница 13: ...low has stopped Release the knob of the adjustment tool to ensure that it no longer makes contact with the crown CAUTION Over adjustment of the crown will cause exces sive spring load in the second st...

Страница 14: ...e intermediate pressure gauge 2 When the intermediate pressure gauge begins to drop below the intermediate pressure lockup the magnahelic gauge should indicate an opening effort of 6 of H2O to 1 0 of...

Страница 15: ...ECTIVE BREATHING TEST 1 While the regulator is connected to a cylinder containing 3 000 psi and pressurized turn the second stage adjustment knob completely out counterclockwise to the full positive p...

Страница 16: ...erly engaged with 2 Disassemble and inspect condi Poppet LP Seat Assy 27 tion of Poppet LP Seat Assy 3 Crown 21 incorrectly adjusted 3 Reset crown and perform Final lever 26 set too low Tuning Testing...

Страница 17: ...blade screwdriver Crown removal installation N A 22mm wrench crow foot Hex nut removal installation N A 11 16 wrench crow foot IP hose fitting 1078 46 Circlip Retaining Ring Tool C clip retaining ring...

Страница 18: ...Slight leak Knob turned in CW 1 2 3 4 turn None Intermediate pressure Inlet 2 500 3 000 100 psi 140 5 psi Intermediate pressure creep Inlet 2 500 3 000 100 psi 5 psi max between 5 to 15 seconds after...

Страница 19: ...esh Water Rinse If tap water is extremely hard distilled water may be used to prevent any mineral residue Remove parts from the neutralizing bath and place directly into this rinse Agitate lightly and...

Страница 20: ...7922 White distilled vinegar Acid bath for reuseable stainless Household grade 100 gr steel and brass parts Liquid dishwashing detergent Degreaser for brass and stainless steel parts Household grade d...

Страница 21: ...Impulse Second Stage Service Repair Manual 19 1997 U S Divers Co Inc TECHNICIAN S NOTES...

Страница 22: ...e Adjustment Switch 15 1094 38 Mouthpiece Comfo Bite Black 16 1049 13 Clamp Black 17 1078 11 Exhaust Tee Key Part Description Key Part Description 18 8601 37 C clip 19 1078 22 Exhaust Valve 20 8200 10...

Отзывы: