106636-02 - 12/19
4
X-2
Installation, Operating & Service Manual
Figure 1-4: Minimum Alcove Clearances
1
Dimensional and Physical Data
(continued)
Figure 1-3: Minimum Closet Clearances
*
Minimum radial clearance around vent pipe and breeching for single-wall metal pipe vent connector.
Otherwise, follow vent connector manufacturer's recommended clearances.
**
Additional height required to maintain 6" clearance from all breeching components. Vent damper may
be installed in vertical or horizontal section of vent connector within reach of vent damper harness.
***
Area of each opening to be 1 sq. inch for each 1000 BTU/hr input - with minimum of 100 sq. inches. Height
of opening should be half of width. 3" minimum dimension for air openings.
Model
"W"
X-202
14"
X-203
14"
X-204
16"
X-205
19"
X-206
22"
X-207
25"
X-208
28"
Model
"W"
X-209
31"