Mounting

 

 

We recommend to install reader on the wall next to the door 
from the lock side. Reader should be installed in the way that 
is  convenient  for  all  users.  Make  small  recess  or  hole 
(diameter is 14 mm) to connect cable under the reader's case.

 

Do  not

 

place  the  reader  on  metal  surfaces,  since  it  causes 

decreasing of read range. If more than one reader is used in 
the  system,  place  them  not  closer  than  20  cm  one  from 
another to eliminate the effect of double reading.

 

Reader Installation 

  Loosen the screw at the bottom of the reader.  

  Remove the top cover, remove the back plate. 

  Mount the back plate of reader on the wall using the fixtures 

provided (see fig. 2). 

  Prepare all wires for connection and connect them to the reader 

in according to Table 1 and User Manual of the access control 
panel to be utilized.

 

  Insert the reader in the back plate (see fig. 

3). 

  Put the top cover and tighten screw at the 

bottom of the reader. 

  Ensure that all locking tabs are securely 

engaged. 
 

The Reader Operation 

RFID Card Code Reading 

Code is read when a valid RF ID is passed. 
Card code reading is annunciated by embedded buzzer and LED lamp according to the interface type 
and annunciation mode (see Section «Data transfer and Annunciation»).

 

Subsequent reading will be available in 0.8 sec only after card removed from the reader sensing area.

 

U-Prox ID code reading 

Download and install mobile software U-Prox Mobile ID. It enables to receive, store U-Prox ID and 
transfer ID code between reader and smartphone.  
Get the U-Prox ID identifier from U-Prox Desktop localy, or remotely by e-mail 
or QR code

Hold mobile device near the reader (standard distance is 10-40 cm) and press 
the button "Open" in app. 
The  application  will  execute

 

data  exchange.  The  card  code  reading  is 

annunciated by embedded buzzer and LED according to the interface type and 
annunciation mode (see Section «Data transfer and Annunciation») 

Hold Mode  

Reader turns to the hold mode while yellow wire is shorted to ground. In this mode, reader does not 
read cards that reduces the current consumption to 25 mA.

 

Relay or an open collector transistor can switch on hold mode. 

It is prohibited to supply the external voltage to the yellow wire! 

Data transfer and Annunciation 

Reader has bicolour LED indicators and buzzer.Their control depends on the interface type. 

Wiegand Interface  

Engaging  of  LED  and  buzzer  is  automatic  or  by  grounding  of  corresponding  wire  (see  Section 
«Wiring»)  

 
 

Figure 3

 

U-Prox ID

 

Figure 2

 