The deployment is made in three steps (see Fig. 6.): 

1. 

U-Prox IC L control panel connection 

2. 

U-Prox HE repeaters connection 

3. 

U-Prox IP500 wireless panels connection 

 

Fig. 6. Wireless lock system deployment 

The algorithms for operation on each step described below 

Server addresses automatic configuration for U-Prox IC L 

1. 

Panel checks for DHCP mode ON (panel address 0.0.0.0) or static IP 

2. 

If DHCP mode is ON, the dynamic IP address obtain routine will start 

3. 

The panel automatic configuration mode starts if the access control system 
IP address (IP or DNS name) is not set: 

a. 

Panel  sends  data  packages  announcing  access  control  system 
server about itself as a new device in the local network 

Despite  it  is  broadcast  announcement  it  limited  with  one  range 
local  network  and  active  network  equipment.  That’s  why  the  IP 
addresses  of  the  access  control  system  server  are  to  be  set 
manually for networks with sophisticated topology. 

b. 

The  system  will  warn  operator  after  the  receiving  of  the  data 
package  from  the  new  panel.  Than  operator  must  add  panel  to 
the system database (DB). 

c. 

After  the  panel  added  to  the  DB  it  receives  the  answer  from the 
access control system server. The address of the access control 
system  server  recorded  into  the  control  panel  and  it  stops  to 
broadcast. 

Содержание IC L

Страница 1: ...1 003 Access control panel U Prox IC L Installation and programming manual...

Страница 2: ...ment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service centers si...

Страница 3: ...tion 9 Communicator operation 9 Wireless lock system architecture 12 Wireless lock system deployment 12 How to work with the device 15 Connection 15 Mount recommendations 16 Communication 16 Wired com...

Страница 4: ...E Panel can connect to a Power over Ethernet PoE switch or injector simplifying installation and eliminating the need for expensive additional wiring U Prox IC L has advanced hardware capabilities and...

Страница 5: ...non 1 EU 868 0 868 6 MHz ITU Reginon 2 USA 902 5 914 5 MHz ITU Reginon 3 AUS 915 5 927 5 MHz o Guaranteed range of 20 m o U Prox HE and U Prox HW repeaters for range extention One micro USB B port for...

Страница 6: ...he access control system implying control of passing through a door in one direction It consists of reader access control panel or its part door supervision devices like door contact RTE button etc an...

Страница 7: ...U Prox IC L modification 1 Figure 2b U Prox IC L modification 2 Location of jumpers and connectors on control panel board and their function is shown in Fig 2 a and b 1 The Enclosure 2 Ethernet port...

Страница 8: ...signment of the access control panel Contact Name Purpose 12V 12V External 12V power supply connection GND GND USB Connector Micro USB B USB Connector For network settings configuration and firmware u...

Страница 9: ...in Service Maintenance section In the Normal mode panel processes information from U Prox IP500 panels received through the built in wireless ISM band interface or via U Prox HE and U Prox HW repeater...

Страница 10: ...http u prox com 10 Figure 3 Mixed type Ethernet Wi Fi local network connection example...

Страница 11: ...the access control panel 2 Update of IP status of address announcement and extension of reserved IP if DHCP 3 Determine accessibility of ACS server IP or DNS name 4 Periodic sending of test signals 5...

Страница 12: ...ontrol panel routes data from the allowed U Prox IP500 wireless panels via U Prox HE and U Prox HW repeaters The U Prox access control system server U Prox IC L U Prox HE and U Prox HW communicate eac...

Страница 13: ...ystem IP address IP or DNS name is not set a Panel sends data packages announcing access control system server about itself as a new device in the local network Despite it is broadcast announcement it...

Страница 14: ...ive network equipment That s why the IP addresses of the U Prox IC L panel are to be set manually for networks with sophisticated topology b The system will warn operator after the receiving of the da...

Страница 15: ...access control system eliminating panel control capture with another system Return panel to the factory settings to eliminate the panel connection to the system 3 U Prox IP500 returns to the normal op...

Страница 16: ...nect the wires Communication U Prox IC L uses wired computer networ for connection to the access control system server With computer program Configurator the adjustment of following parameters provide...

Страница 17: ...ta transmission speed is 100Mbit sec The Ethernet connection examples are on the Fig 9 Connector 1 Connector 2 Direct connection Connection to switch or router 1 white yellow 1 white yellow 2 yellow 2...

Страница 18: ...order Software Actions 1 Define desirable adjustment mode automatic or manual Configurator through the USB 2 Adjust initial settings if manual configuration used a Server settings IP address or server...

Страница 19: ...ming mode do the following 1 Do not turn off the power 2 Open enclosure 3 Connect cable to the USB and configure the device using the software Configurator Replacing the device firmware 1 De power the...

Страница 20: ...http u prox com 20 Reference for device installation modification 2...

Отзывы: