9
"Normal" mode
This is the main mode of panel. In this mode the panel grants or denies access to
RF ID owners. In “Normal" mode the readers blink red.
Using elevator buttons after passing RF ID
To use elevator buttons user enters contactless RF ID to the reader. If RF ID is
registered and the passage granted, panel activates the relay modul
es’ outputs
according to the user access rights and floor selection buttons’ loops switched on.
The reader LED becomes green. User may select floor with button during adjusted time.
Using elevator buttons after passing RF ID and PIN entering
On entering enrolled RF ID, panel tests whether PIN code is required, and, if
required, waits for entering PIN code. After entering the correct PIN code, panel
activates the relay modules’ outputs according to the user access rights and floor
selection buttons’ loops switched on. The reader LED becomes green. User may
select floor with button during adjusted time.
Access denial upon entering RF ID
Access may be denied to RF ID owner due to the following reasons (the reader LED
is red):
Cards (RF IDs) and schedules are not loaded in the panel
access control panel is in unloaded state
card is not enrolled in the panel
card term expired
RF ID passed out of schedule
entered RF ID is marked as lost or blocked
the panel is in "Alarm" mode (LED is constantly on and red)
the panel is in "Blocked" mode (LED flashes red and yellow)
pass count is exhausted for the temporary card (visitor).
“Alarm” Mode
In "Alarm" operation mode the reader indicator is constantly red. Depending on the
programmed functions panel goes into mode
"Alarm"
in case of opening of panel
cover, entering RF ID recorded as lost and in case of RF ID matching attempt.
If panel is
in “Alarm mode", use of floor selection buttons prohibited. One may
activate floor selection button with U-Prox RM relay module input.
To exit from the "Alarm" mode pass the ID with "Disalarm" attribute or by command
from the computer.