R-600A Specifications

USER GUIDE

 R-600A Specifications 3

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •

SERVICE

Evacuate/reclaim via the piecing pliers to ensure the 
system is empty of R-600a before any system work is 
performed.

The recovery cylinder must be evacuated (no air inside) 
prior to accepting R-600a.

The recovery cylinder must not be filled more than 45% 
safe fill level and refrigerants must not be mixed.

The recovery cylinder must be clearly marked with R-
600a and Flammable Warning labels. 

Ensure proper ventilation during recovery/reclaiming of R-
600a.

Start vacuum pump/recovery pump prior to piercing the 
compressor process tube.

Follow recovery/reclaim OEM instructions for the specific 
equipment used.

SYSTEM REPAIR

Ensure no residual R-600a refrigerant is left within the 
system prior to repair (simple venting is not sufficient).

Evacuate and charge with dry nitrogen for leak checks.

Repair leaks or replace system parts as required. 

When re-brazing, the system must be purged with dry 
nitrogen and at least one access point open to the 
atmosphere.

When re-brazing, proper ventilation is required along with 
constant monitoring for the presence of R600a refrigerant. 

The filter dryer must be replaced any time the sealed 
system is serviced. 

No system should be open to the atmosphere for longer 
than 15 minutes to avoid moisture migration into the 
system components.

LEAK DETECTION

After removal of the R-600a, the unit can be charged with 
dry nitrogen or helium.

Electronic leak detection or soap solution can be used to 
check for nitrogen/helium leaks.

Never use a halide torch or lighted match to check the 
system for leaks at any time. 

The high side of the refrigeration system (compressor 
discharge to outlet of drier) must be leak tested with the 
compressor running.

34

Содержание UHRE524-SS81A

Страница 1: ...USER GUIDE SERVICE MANUAL Model UHRE524 SS81A...

Страница 2: ...on Grille Installation Door Swing Door Stop Door Adjust Interior Adjustments Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Airflow and Pro...

Страница 3: ...HT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are available digi...

Страница 4: ...oderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do n...

Страница 5: ...e so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refriger...

Страница 6: ...ures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating e...

Страница 7: ...it Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been pl...

Страница 8: ...al connection in the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP SIDE 4 102 mm 7 178 mm 33 7 8 860 mm to 34 7 8 886 mm 23 3...

Страница 9: ...ide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintained bet...

Страница 10: ...roper fit Also test to make sure the door opens and closes freely 3 Remove grille and place a mark on the floor at the front of the unit Also place a mark on the floor in the center of the unit 4 Remo...

Страница 11: ...ing s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is corre...

Страница 12: ...t the grille must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two screws...

Страница 13: ...l space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clearance on hinge side to allow for door h...

Страница 14: ...90 2 Slide hinge pin into hole as shown Pin should slide into place stopping the door at 90 if the pin does not go into the hole shown hold the door less than 90 open and try again 3 To fully seat th...

Страница 15: ...ch pair of Torx head screws both the upper and lower hinge plates 3 Square and align door as necessary 4 Tighten Torx head screws on hinge 5 Reinstall gasket into the channel starting at the corner RE...

Страница 16: ...rned off during installation simply press and the unit will immediately switch on To turn the unit off press If the temperature displayed is different than selected the unit is progressing towards the...

Страница 17: ...for 5 seconds The display will change units Hide Display Hold and press Display will turn off when door is closed Unit will continue to operate Repeat command to turn on display Enable Sabbath Mode Pr...

Страница 18: ...rol Operations sections for details and other options For more information about BrightShield visit www u line com For more information about Vyv Antimicrobial Light Technology visit www vyv tech Test...

Страница 19: ...es Not all bottles and cans will fit on every shelf and wine rack Larger diameter champagne and Magnum bottles only fit on wine racks when noted on the product specifications When determining capaciti...

Страница 20: ...es Note The slides on the frame have a thin coating which is used to block moisture and provide lubrication Use care when handling Slide and Secure Storage Bin Installation 1 Insert empty storage bin...

Страница 21: ...eel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels us...

Страница 22: ...tive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow t...

Страница 23: ...mental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condenser uni...

Страница 24: ...evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open...

Страница 25: ...akes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before d...

Страница 26: ...ing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal temperatures of th...

Страница 27: ...L T Door switch R B Door switch L T Evap temp R B Zone temp R B Evap temp Open Programming Diagnostics VCC Control Display 42392_B 1 5 1 6 1 4 If Applicable If Applicable If Applicable If Applicable I...

Страница 28: ...replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the dat...

Страница 29: ...r warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warran...

Страница 30: ...5 00 10 DRAIN PAN 80 54217 00 11 DRIER 80 54055 00 12 EVAPORATOR ASSEMBLY 80 55486 00 13 EVAPORATOR COVER 80 55485 00 14 EVAPORATOR FAN W COVER 80 55457 00 15 GASKET DOOR 80 54039 00 16 GLASS SHELF 80...

Страница 31: ...ranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform...

Страница 32: ...ust observe all federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fi...

Страница 33: ...pump and recovery equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system p...

Страница 34: ...is left within the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the sy...

Страница 35: ...ll a Schrader Type access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minu...

Страница 36: ...mely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near ro...

Страница 37: ...not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully an...

Страница 38: ...istance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite this tec...

Страница 39: ...OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Thermistor failure OHM thermistor Displa...

Страница 40: ...ger Switch Replace Main Board Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Plunger Switch Operating Properly Inspect Customer UI and Data Cable Connect Test Display Cycle Pow...

Страница 41: ...t this mode hold the light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allow the...

Страница 42: ...mp alarm limit Model 55 only 1 THERMISTOR 1 ZONE This shows the pure thermistor reading with no offsets taken into account 2 THERMISTOR 2 EVAPORATOR This shows the pure thermistor reading with no offs...

Страница 43: ...ODEL 54 ONLY 31 LOW TEMP ALARM LIMIT MODEL 55 ONLY 32 HIGH TEMP ALARM LIMIT MODEL 55 ONLY Display Relay Output Option 0 Exit Option 1 Relay 1 Option 2 Relay 2 Option 3 Relay 3 Option 4 Relay 4 Option...

Страница 44: ...Fan 43 BD524 1A Compressor Top Left Valve Bot Right Valve Light 1 Light 2 Evap Fan Evap Fan 2 Cond Fan 48 WD524 1A Compressor Top Left Valve Bot Right Valve Light 1 Light 2 Evap Fan Evap Fan 2 Cond Fa...

Страница 45: ...e operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost THERMISTOR FAILURE Zone Thermistor If the zone thermistor in the unit fails the unit...

Страница 46: ...hours of compressor runtime for 45 minutes If you have verified that the unit does not have an ambient air leak refer to the Control Operation Service section and adjust unit to defrost every 9 hours...

Страница 47: ...te air and clear any condensation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door switch In...

Страница 48: ...mounting location 13 Installation is the reverse of removal 14 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the train trough 15 Use sealant g...

Страница 49: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Отзывы: