USER GUIDE
u-line.com
Troubleshooting Extended
REPLACING ICE MAKER ASSEMBLY (ALL MODELS
EXCEPT CO29F)
1. Remove back panel.
2. Disconnect all wires at bell connectors (5 wires-Models
BI95, BI98 or SP18; or Plug-Models).
3. Remove capillary tube from sensing tube on ice maker
assembly (2).
4. Remove water inlet tube.
5. Remove front cover (3)
6. Advance ejector blades to the 3:00 position by turning the
5/16" hex head on the small brass gear counterclockwise
(4).
7. Remove two screws from the side wall of evaporator (5).
8. Remove screws from the bottom of the evaporator plate.
9. Remove ice maker assembly from evaporator shelf.
10. Clean alumilastic from evaporator shelf.
11. Apply 1/4" layer of fresh alumilastic to heater side of new
ice maker.
12. Replace parts in reverse order of removal.
13. Reconnect all wires.
14. Insert capillary tube into ice maker sensing tube.
15. Insert water inlet tube.
16. Apply permagum to all exit holes. Mount back panel.
17.Mount the back panel.
18.Plug in unit and test.
220 Volt Conversion List
All models listed in this manual are equipped to run on
110/115 volt. This document is a conversion list for the
applicable 220 volt parts for the following models:
•
SP18
•
BI95
•
BI98
•
SS1095
110V P/N
220V P/N
Description
5263-S
5195
Fan Motor
80-39015-00
628109
I.M. motor (ice makers)
402
619
Ice maker assembly -
Models SP18, BI95, BI98
and model SS1095
402-29/1175
620
Ice maker assembly -
Models SP18, BI95, BI98
and model SS1095
2552A
2555A
Water valve
5402-S
5404-S
Compressor (ice makers)
150
650
Faceplate assembly
5414
5418
Relay
5413
5417
Overload
45