Cleaning

NOTICE

Use only U-Line Clear Ice Machine Cleaner 
(80-55667-00), available for purchase from    
u-line.com or your dealer. It is a violation of 
federal law to use this solution in a manner 
inconsistent with its labeling. Use of any other 
cleaner can ruin the finish of the evaporator and 
will void the warranty. Read and understand all 
labels printed on the package before use.

U-Line Clear Ice Machine Cleaner is used to remove lime 
scale and other mineral deposits. Refer to the following 
steps to initiate the self-cleaning cycle.

Never use anything to force ice from the 
evaporator. Damage may result.

1. 

Turn the ice machine off and allow any ice to melt off 

of the evaporator.

2.  Remove all ice from the storage bin.

3.  Remove evaporator cover.

4.  Remove the standpipe by 

lifting it up while using 
a slight back and forth 
motion to loosen it from 
the drain hole. The water 

in the reservoir will flow 

down the drain.

5.  Re-install the standpipe into the water trough.

6.  Clean the Interior Bin as 

follows:

•  Dilute 1-2 oz. of Clear Ice 

Machine Cleaner into two 
quarts of water.

•  Using a sponge or cloth, clean interior of ice bin, 

tubing and door. This cleaner will remove all mineral 
deposits and other contaminants from the surfaces.

CAUTION

!

•  Using a bottle brush, clean 

out the trough drain tube 
and pump tubing where 
needed.

7.  Turn unit on by pressing     .

8.  Place unit into CLEAN mode by holding      for 5 

seconds.

9. 

When water begins flowing over the evaporator 

(approximately 3 minutes), pour 1-2 oz. of Clear Ice 
Machine Cleaner into the water trough. The cleaning 
process will last approximately 45 minutes.

10.  Dilute 1 tablespoon bleach in 1 gallon of warm water. 

Apply this solution to the entire inside of the storage 
area. Then rinse thoroughly with water.

The unit will resume operation approximately 15 minutes 
after the automated cleaning process is completed. The 

water fill valve will energize, fill the water reservoir, and 
shut-off after three minutes. The compressor begins to 
operate and water flows over the evaporator assembly 
(ice mold). Initially, the water flow may not be uniform, 

causing uneven sized cubes or water to spill into the ice 
storage bin. This is a normal situation that will correct 

itself within the first 24 hours of operation.

NOTICE
Discard all ice produced in the first harvest.

Should power to the unit be interrupted during 
the self-clean cycle, it will be necessary to 
repeat the complete cleaning cycle after power is 
restored.

REFRESH KIT

Due to variations in water quality or inadequate 
maintenance your unit may become excessively coated 

in lime scale or calcium. U-Line offers a cost effective 

refresh kit which replaces many interior components and 
will return your unit to like new condition. Refresh kits 
may be ordered from your local distributor and installed by 
your local service company. For information on your local 
distributor or service company please visit 
www.u-line.com.

Evaporator cover

Standpipe

Evaporator

Water trough

ULIN_0060_A

Brush

26

Содержание UHCP115-SS81A

Страница 1: ...USER GUIDE SERVICE MANUAL Model UHCP115 SS81A...

Страница 2: ...n Water Hookup Drain Anti Tip Bracket General Installation Grille Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control...

Страница 3: ...ne RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are availabl...

Страница 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...mperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat genera...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...N Unit can NOT be installed behind a closed cabinet door If you would like to align the face of the unit with other adjacent cabinet doors you may need to alter the wall just behind the drain connecti...

Страница 9: ...ed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as show...

Страница 10: ...nnection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Connect to the cold water supply The water pressure shoul...

Страница 11: ...reates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break away filler featur...

Страница 12: ...he rate of 1 4 per foot 1 cm per 50 cm Drain can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connec...

Страница 13: ...e ordered a pre installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain p...

Страница 14: ...ver holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water li...

Страница 15: ...n opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is...

Страница 16: ...unit the grille must be installed Removing the grille 1 Disconnect power to the unit 2 Slightly loosen three screws on bottom hinge 3 Remove two grille screws 4 Slide grille to the left and remove Ins...

Страница 17: ...adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance i...

Страница 18: ...from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is fi...

Страница 19: ...pulling outward exposing the gasket channel 3 Remove the 3 pieces of gasket channel filler and reinstall on the opposite end of door 4 Install gasket into channel beginning at one corner and pressing...

Страница 20: ...ine recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line When plugged in the unit will begin op...

Страница 21: ...Adjust ice thickness See Ice section Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain...

Страница 22: ...Control Operations sections for details and other options For more information about BrightShield visit www u line com For more information about Vyv Antimicrobial Light Technology visit www vyv tech...

Страница 23: ...bridge becomes thicker the tendency for the cubes to stay together as a slab increases A bridge thicker than 1 8 3 2 mm may cause cubes to overfill the ice bucket 32 ice cubes are formed on a 4 x 8 sl...

Страница 24: ...u line com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected D...

Страница 25: ...mmend appropriate treatment Wear rubber gloves and safety goggles and or face shield when handling Ice Machine Cleaner Clean surfaces with a mild detergent and warm water solution Do not use solvent b...

Страница 26: ...lding for 5 seconds 9 When water begins flowing over the evaporator approximately 3 minutes pour 1 2 oz of Clear Ice Machine Cleaner into the water trough The cleaning process will last approximately...

Страница 27: ...nvironmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condens...

Страница 28: ...r must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or...

Страница 29: ...omponents with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that may...

Страница 30: ...nt of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial numb...

Страница 31: ...shes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may su...

Страница 32: ...18 HI TEMP THERMISTOR 80 54070 00 19 HINGE ASSEMBLY 80 55595 00 20 ICE SCOOP CLR 80 54080 00 21 LIGHT ASSENBLY VYV 80 54000 01 22 LEG LEVELERS 4 80 54019 00 23 MAGNET W SCREWS 2 80 54250 00 24 MAIN BO...

Страница 33: ...s will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U L...

Страница 34: ...Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near ro...

Страница 35: ...tic wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the...

Страница 36: ...s some diagnostic tips and as always if additional help is required please contact the U Line Corp Customer Care Facility at 1 800 779 2547 for assistance NORMAL OPERATING SOUNDS All models incorporat...

Страница 37: ...level unit if needed Low Ice Production Dirty evaporator dirty condenser faulty bin thermistor Clean the evaporator using U Line cleaner clean the condenser coil if needed check bin thermistor reading...

Страница 38: ...low chart below to help diagnose the issue Before beginning it is important to first verify the unit is not simply set to sabbath mode Check Voltage At Wall Outlet Verify Voltage At Main Control Volta...

Страница 39: ...re Navigates through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activates...

Страница 40: ...he light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allow the use of the contro...

Страница 41: ...to this model E5 Thermistor 1 shorted E6 Thermistor 2 shorted E7 Thermistor 3 shorted E8 Thermistor 4 shorted Does not apply to this model E9 Door 2 lower open P1 Pump Circuit open Does not apply to t...

Страница 42: ...s will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was entered 24 ACTIVATE DEFROST HARVEST Turns on the hot ga...

Страница 43: ...conds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will appear as the programmed d...

Страница 44: ...ator Fan Condenser Fan N A N A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC...

Страница 45: ...ain the operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost THERMISTOR FAILURE Zone Thermistor If the zone thermistor in the unit fails th...

Страница 46: ...USER GUIDE Defrost 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These models have no defrost options 46...

Страница 47: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: