![U-Line UCFZ527-SS31A Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/u-line/ucfz527-ss31a/ucfz527-ss31a_user-manual_3183569034.webp)
Always switch off the unit and disconnect power cord before cleaning, it is dangerous
to do it with power ON: fan may start suddenly at any time.
Use a convenient ladder to reach the condenser. Use an air jet or vacuum with a soft dry brush if
necessary and remove any dust or fluff from the heat exchanger fins.
After cleaning, start the equipment.
During the cleaning operation wear gloves and safety glasses to protect yourself from any
injury
5. TROUBLESHOOTING
The Chart shows the most frequent breakdowns , possible causes and relative remedies:
PROBLEM DESCRIPTION
POSSIBLE CAUSE
SOLUTION
The appliance does not come on
The main switch is "off"
There is no tension
Other
Main switch “on”
Check plug, socket, electric connection
Contact technical assistance
The refrigerator unit does not start Set temperature is reached
Defrosting is in operation
Control Panel is broken
Other
Set new temperature
Wait for end of cycle, switch off and switch back
on
Contact technical assistance
Contact technical assistance
The refrigerator is continuously
working but does not reach the set
temperature
Room is too hot
Condenser is dirty
Refrigerant fluid is insufficient
Condenser fan has stopped
Door not properly closed
Evaporator is frosted up
Defrost valve is open
Air better
Clean condenser
Contact technical assistance
Contact technical assistance
Check door seals
Manual defrosting
Contact technical assistance
Refrigerator does not stop at set
temperature
Control Panel is broken
Temperature probe is broken
Door is not airtight
Contact technical assistance
Contact technical assistance
Close door
Ice blocks on evaporator
Improper use
Control Panel is broken
Contact technical assistance
Contact technical assistance
Appliance is noisy
Appliance not levelled
Contact with external bodies
Screws or nuts loose
Other
Check that appliance is level.
Check that no tube or ventilator fan is in contact
with external bodies.
Tighten
Contact technical assistance
Safety DC fan does not work
Fan disconnected
Stuck fan
Fan motor damaged
Re-wire the fan to the electrical strip contact
Replace the fan
Replace the fan
37
Use and Operational Manual
31
Содержание UCFZ527-SS31A
Страница 25: ...OPERATION 3 3 14 Electrical connection 22 Use and Operational Manual 22...
Страница 26: ...OPERATION 3 3 15 Default parameters value and description 23 Use and Operational Manual 23...
Страница 27: ...OPERATION 24 Use and Operational Manual 24...
Страница 28: ...OPERATION 25...
Страница 29: ...OPERATION 26 26...
Страница 30: ...OPERATION 27 Use and Operational Manual 27...
Страница 31: ...OPERATION 28 Use and Operational Manual 28...
Страница 54: ...51 FUNCTIONNEMENT 3 3 14 Connexion lectrique 90 Use and Operational Manual...
Страница 55: ...FUNCTIONNEMENT 3 3 15 Valeur et description des param tres par d faut 91 Use and Operational Manual 52...
Страница 56: ...53 FUNCTIONNEMENT 92 Use and Operational Manual...
Страница 57: ...FUNCTIONNEMENT 54...
Страница 58: ...55 FUNCTIONNEMENT...
Страница 59: ...FUNCTIONNEMENT 56...
Страница 60: ...57 FUNCTIONNEMENT...