USER GUIDE
Extended Non-Use
Drain Pump Removal
1. Unplug the ice machine from the electrical supply and
remove the rear access cover from the ice machine.
2. Remove the front panel and the toe grille from the
front of the ice machine.
3. Remove the front and rear drain pump brackets.
4. Unscrew the 3 hose clamps and remove the 3 hoses
from the front of the drain pump.
5. Unscrew the leveling leg in the back corner until the
end of the threaded portion is flush with the threaded
nut insert in the base.
To Restart the Ice Machine
6. Reconnect or turn on the water supply line.
7. Reconnect drain tubing if removed.
8. Plug in the power cord to a wall outlet and turn the ice
machine on.
9.
Check the water inlet, drain lines, and fittings for any
water leaks.
10. Check drain pump (if equipped) operation by pour-
ing approximately two (2) quarts of water into the
ice storage bin. The drain pump should activate and
discharge water. Check for water leaks at all hose
connections.
Unscrew the
leveling leg so
the end of the
threads is flush
with the top of
the nut insert.
Remove
these 3 hose
clamps, then
remove the
3 tubes from
the drain
pump
Drain pump ground
wire connection
26