U-Line U-CO1175B-00 Скачать руководство пользователя страница 20

18

u-line.com

CAUTION

!

Prior to attempting installation, determine if this product 
contains a gravity style drain or factory installed drain 
pump. Products without a drain pump may only use a 
gravity style drain. Failure to connect water supply or 
drain line connections properly may result in water 
leakage, personal injury, and/or property damage. 
Disconnect power and turn off water to the unit before 
attempting to alter these connections. Please consult 
U-Line or your installation instructions for further details. 
These connections are the responsibility of the owner and 
must be connected per local plumbing code. If you are 
uncertain of how to safely and properly install this 
product, contact a licensed plumber. 

Water Connections:

CAUTION

!

Review, obey, and understand the local plumbing codes before you install your unit. Connect to the cold water supply. 
The water pressure should be between 20 and 120 psi. The water line MUST have a shut-off valve on the 1/4" supply line.

NOTICE

• U-Line requires the use of copper tubing for installation or the U-Line water hookup kit available at www.u-line.com. 

This kit includes a flexible water supply connecting hose and brass fitting.

• Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age 

and cause damage to your home.

• Do not use Teflon tape or joint compound on the water fitting. The rubber washer provides an adequate seal. Other 

materials could cause blockage of the valve.

Copper Water Supply Connection:

CAUTION

!

Turn off water supply and disconnect electrical supply to unit prior to attempting installation.

1. Turn off water supply and disconnect electrical supply to product prior to attempting installation.

2. Locate the desired cold water supply location.

3. Attach a 1/4" copper line to this location and route the tubing to the appliance. Leave approximately 8’ of water line to be coiled behind 

the appliance. The water line should be looped into 2 coils. This will allow the line to flex when removing the unit for cleaning and service. 
Do not kink or pinch the coiled line. 

4. Locate the U-Line supplied hose fitting. Ensure the end on the copper tubing has been cut straight and is free of burrs. Slide the 

compression nut and ferrule onto the copper tubing as shown below.

5. Push the assembly completely into the garden hose fitting and 

tighten.

6. Attach the copper water line to the back of the unit using the 

supplied clamp and the back panel screw. This will prevent rotation 
of the line when moving the unit. 

7. Turn on water and check for leaks. 

11 Prepare Plumbing

9/16" Wrench

1/4" Copper Water

Supply Line

7/16" Wrench

From Water  Supply

to Ice Maker

Compression Nut

Ferrule

Содержание U-CO1175B-00

Страница 1: ...CLR2160W 40 CLEAR ICE COMBO MODELS U CLRCO2175B 00 U CLRCO2175B 40 U CLRCO2175S 00 U CLRCO2175S 01 U CLRCO2175S 40 U CLRCO2175S 41 ICE COMBO MODELS U CO1175B 00 U CO1175B 20 U CO1175S 00 U CO1175S 01...

Страница 2: ...Doors Self Closing Door Alignment and Adjustment 8 Door Reversability 8 Reversing Black or White Doors 9 Reversing Stainless Steel Glass Doors 10 8 Door Panel Installation Custom 1 4 Thick Door Panel...

Страница 3: ...ily climb inside WARNING SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round ground...

Страница 4: ...iers Copper tubing CO2175 Models Only Full Overlay Door Panel Kit Part number U OL2175B black units U OL2175W white units A complete water hook up kit is also available for purchase from your dealer O...

Страница 5: ...Series Follow the cut out drawing The 15 1 4 width allows 1 4 for ease in installation and removal of the unit 24 is the cabinet depth in most installations CO29 Series Follow the cut out drawing The...

Страница 6: ...1 8 15 15 Black and White Stainless Steel 23 3 16 3 7 8 23 1 8 3 15 16 Add 3 4 To Depth For Drain Line Clearance Add 3 4 To Depth For Drain Line Clearance CO1175 Series BLACK CO1175 23 1 4 34 1 8 23 1...

Страница 7: ...are designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures and may also reduce the ice production...

Страница 8: ...doors without locks are field reversible See the table at the front of this book for a summary of units that are reversible Stainless steel models without glass doors must be ordered right or left han...

Страница 9: ...ctuator bracket 5 Remove door actuator 4 from door Be sure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate w...

Страница 10: ...op edge of door is parallel with top of cabinet and tighten screws 1 securely 5 After adjustment is complete remove the door closers from the bottom hinge clean thoroughly and apply petroleum jelly to...

Страница 11: ...3 Remove door by tilting forward and lifting door off bottom hinge closer inserts 4 Reinstall hinge screw pin 1 into top hinge using a Phillips screwdriver Remove hole plugs Remove plastic screw plug...

Страница 12: ...into position 4 Hold door to keep it from falling 5 Reinstall hinge screw pin 1 into top hinge using a Phillips screwdriver Align and adjust the door Align and adjust the door see DOOR ALIGNMENT AND...

Страница 13: ...p 1 to top of door opposite handle 5 Install pivot plat to bottom of door opposite of handle using hardware removed in Remove Stainless Frame step 2 Arrange pivot plate so the flat edge is against the...

Страница 14: ...lugs 1 Install plastic screw plugs three each top and bottom 3 into holes where hinge hardware was removed Install Door 1 Hold door upright and tilted forward 2 Lift door on to bottom hinge closer ins...

Страница 15: ...m hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force 3 Remove the two outside screws holding door han...

Страница 16: ...ner that the grille assembly can still be removed from the unit Screw Mount Recommended 1 Remove the grille from your unit by removing the two mounting screws See below 2 Lay the back of your grille o...

Страница 17: ...u line com 15 1 4 8 1 2 3 3 32 19 5 8 1 2 1 2 TYP 3X 5 16 TYP 2X 7 16 5 16 10 5 16 11 64 2 1 8 1 2 22 7 8 23 7 8 FULL R Grille Overlay Dimensions 24 Inch Models Grille Drawing 24 inch...

Страница 18: ...16 u line com 1 4 4 5 32 3 3 32 10 5 8 1 2 1 2 TYP 3X 5 16 TYP 2X 15 32 275 5 29 32 11 64 2 1 8 1 2 13 7 8 14 7 8 FULL R Grille Overlay Dimensions 15 Inch Models Grille Drawing 15inch...

Страница 19: ...t requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended GFCI ground fault circuit i...

Страница 20: ...at all times Plastic may crack or rupture with age and cause damage to your home Do not use Teflon tape or joint compound on the water fitting The rubber washer provides an adequate seal Other materi...

Страница 21: ...p please contact U Line The floor drain must be large enough to accommodate drainage from all attached drains Follow these guidelines when installing drain lines to prevent water from flowing back int...

Страница 22: ...P60 pump it is extremely important to check and test all hose connections at the drain pump Test Hose Connections 1 Place a suitable container beneath the pump s discharge tube The container must be a...

Страница 23: ...s 2 Turn on the water supply and ensure the connections are free of leaks 3 Pour 1 gallon of water into the bin and ensure all the connections and fittings are free from leaks 4 Begin to push the appl...

Страница 24: ...first plugged into the electrical outlet Test the drain system by pouring one gallon of water into the ice bin The water should drain freely and there should be no leakage All Models 3 Gently push the...

Страница 25: ...n A The hinges should be self closing when the door is open approximately 8 If this is not the case make sure the closers at the bottom of the hinge pin are clean greased and installed correctly Also...

Страница 26: ...ne Captain Models Combo Models Refrigerator Freezers Refrigerators Drawer Models and Beverage Centers The U Line brand offers products in the 1000 Series 2000 Series and the Modular 3000 Series The 10...

Отзывы: