U-Line U-1075BEVS-00 Скачать руководство пользователя страница 16

13

U-Line Service

Troubleshooting

Compressor Information

Cooling process

Refrigerant is pumped from the compressor to the condenser as a 
high pressure, high temperature vapor.

As the refrigerant cools in the high pressure condenser, the vapor 
condenses to liquid. During this phase change, a great amount of heat 
is rejected with the help of the condenser fan.

The liquid then flows to the dryer where it is strained and filtered.

From the dryer, the refrigerant flows through the capillary tube which 
meters the liquid refrigerant to the evaporator.

The pressure of the refrigerant is reduced to the evaporating or low 
side pressure.

The reduction of pressure on the liquid refrigerant causes it to boil 
or vaporize until it reaches saturation temperature. As the low 
temperature refrigerant passes through the evaporator coil, it 
continues to absorb a lot of heat, causing the boiling action to 
continue until the refrigerant is completely vaporized. It is during this 
phase that the most heat is absorbed (the cooling takes place) in the 
refrigerator.

The refrigerant vapor leaving the evaporator travels through the 
suction line to the compressor inlet. The compressor takes the low 
pressure vapor and compresses it, increasing both pressure and 
temperature. The hot, high pressure gas is pumped out the discharge 
line and into the condenser. The cycle continues.

CAPILLARY TUBE

DRYER 

CONDENSER

COMPRESSOR

EVAPORATOR

Compressors

DANGER

!

Electrocution can cause death or serious injury. Burns from hot 
or cold surfaces can cause serious injury. Take precautions when 
servicing this unit.

• Disconnect the power source.
• Do not stand in standing water when working around 

electrical appliances.

• Make sure the surfaces you touch are not hot or frozen.
• Do not touch a bare circuit board unless you are wearing 

an anti-static wrist strap that is grounded to an electrical 
ground or grounded water pipe.

• Handle circuit boards carefully and avoid touching 

components.

To measure the start winding resistance, measure across the C and S 
pins.

To measure the run winding resistance, measure across the C and R 
pins.

Also check S to R and you should get the sum of the run and start 
windings.

To ensure the windings are not shorted, check the S and R to ground.

EMI30HER

EMU30HSC

EMU40HNP

C

S

R

OVERLOAD PROTECTOR

STARTING RELAY

CAPACITOR (IF EQUIPPED)

RELAY COVER

Voltage

115

115

220

Frequency

60

60

50

Start Winding

21.20

7.0

40

Run Winding

7.9

8.4

30

Содержание U-1075BEVS-00

Страница 1: ...ER REFRIGERATOR FREEZER U 1075WCS 00 U 1075BEVS 00 ULN 29RB 00 ULN 75FB 00 U 1075WCS 02 U 1075BEVS 02 ULN 29RB 02 ULN 75FB 13 U 1075WCS 13 U 1075BEVS 13 ULN 29RB 06 ULN 75FWH 00 U 1075WCS 15 U 1075BEV...

Страница 2: ...onlineservice U Line com fax to 1 414 354 5696 or mail to the address below Pictures of the unit installation and any alleged property damage Inquire when the problem first appeared any prior problem...

Страница 3: ...tenance Leveling 9 Removing and Installing Grille 9 Removing and Installing Interior Shelves 10 Removing and Installing Door Shelves 10 Removing and Installing Wine Racks 10 Troubleshooting Customer C...

Страница 4: ...not easily climb inside WARNING SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round...

Страница 5: ...s Yes ULN 29RB 06 230V Right Hand Hinge Solid Black Door Glass Shelves Yes ULN 29RB 09 230V Right Hand Hinge Solid Black Door Glass Shelves Yes ULN 29RB 13 120V Right Hand Hinge Solid Black Door w Loc...

Страница 6: ...rately Included in labor are freon and recovery charges all other parts are handled by the parts department We require that some parts be returned to us so we may return them to our vendor It will be...

Страница 7: ...Number Part Number Part Description and in some cases Color or Voltage All warranty parts will be shipped at no charge as long as warranty status has been confirmed If we require that a part be retur...

Страница 8: ...nt grille or condenser are obstructed Normal Operating Sounds All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal worki...

Страница 9: ...point can be affected by the ambient conditions The unit is shipped with the control dial in a position suggested for standard room conditions Adjusting Air Temperature NOTICE Adjust the set point tem...

Страница 10: ...doors without locks are field reversible See the table at the front of this book for a summary of units that are reversible Stainless steel models without glass doors must be ordered right or left han...

Страница 11: ...racket 5 Remove door actuator 4 from door Be sure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was remove...

Страница 12: ...ithout adjustable leveling feet NOTICE The unit must be located on a level surface for proper door and ice maker if equipped operation Use a level to check the levelness of the unit from front to back...

Страница 13: ...the door shelf 1 Holding the shelf in the center center the shelf in the door at the desired location slightly above the pins 2 2 Lower the shelf onto the pins 2 Removing and Installing Wine Racks 1 R...

Страница 14: ...ne s warranty is 90 days for door or drawer adjustments Has the door or drawers been left open Is the condenser clean U Line s warranty does not cover cleaning the condenser Is the unit behind closed...

Страница 15: ...electronic control models only Frost Buildup Inside Unit Door ajar or restricted from closing Inspect Repair door closure adjust as needed Display Not Working Unit placed in Sabbath mode electronic co...

Страница 16: ...e suction line to the compressor inlet The compressor takes the low pressure vapor and compresses it increasing both pressure and temperature The hot high pressure gas is pumped out the discharge line...

Страница 17: ...Warm Extremely cold near inlet outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal in vacuum Warm near room temperature Very hot Top passes warm lower passes...

Страница 18: ...remedies Most often this will resolve the problem without the need to call for service If Service is Required If you do not understand a troubleshooting remedy or your product needs service contact U...

Страница 19: ...inless to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Interior Cleaning Disconnect power to the un...

Страница 20: ...fore operating replace all panels Failure to do so may result in death or electrical shock NOTICE If the ambient temperature is expected to drop below 50 F turn off and unplug unit and drain all water...

Страница 21: ...18 U Line Service Cleaning...

Страница 22: ...s The U Line brand offers products in the 1000 Series 2000 Series and the Modular 3000 Series The 1000 Series offers a more targeted priced product with appropriate features while the 2000 Series offe...

Отзывы: