U-Line Service
12
Troubleshooting
Troubleshooting Guide
CAUTION
!
Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected.
Potential Causes
Suggested Remedy
Not Cooling
Compressor overheating
Verify proper air flow through condenser. (Refer to
Airflow/General information Section of this manual)
Confirm condenser fan operation. (Refer to Airflow/
General information Section of this manual)
Compressor not operating
Test overload and relay, replace as needed.
Compressor operating - no cooling
Refer to Refrigeration System Diagnosis Guide Section
of this manual.
Evaporator fan not operating
convect cool models only
Refer to Convection Cooling Section of this manual.
convect cool models only
Frozen Product
Control set too cold
Refer to Adjusting Air Temperature Section of this
manual.
Review logged error codes
electronic control models only
Refer to Fault System Diagnosis Guide Section of this
manual.
electronic control models only
Thermistor failure
electronic control models only
Refer to Thermistor Failure Section of this manual.
electronic control models only
Frost Buildup Inside Unit
Door ajar or restricted from closing
Inspect/Repair door closure, adjust as needed.
Display Not Working
Unit placed in Sabbath mode
electronic control models only
Refer to Sabbath Mode Section of this manual.
electronic control models only
Display unplugged
electronic control models only
Verify that both ends of the display wiring are firmly
connected.
electronic control models only
Display wiring broken or damaged
electronic control models only
Perform continuity test of wiring and replace as needed.
electronic control models only
Internal Lights Not Working
Door switch misaligned or defective
Check light switch, wiring and acuator. Adjust as needed.
Door switch misaligned or defective
electronic control models only
Refer to Reed Switch Section of this manual.
electronic control models only
Noisy
Refrigeration tubing touching cabinet
Carefully reposition tubing.
Fan blade obstruction (wiring, foam insulation, packaging
material)
Remove obstruction.
Ice Buildup In Drain Trough or Drain
Problem
Obstructed drain cup or tube
Clear as needed, test flow.
Kinked condensate drain line
Reroute condensate drain line and test flow.
Drain trough and cup misaligned
Trough is slotted for adjustment. Loosen retainers and
adjust as needed.