Turn the detector on by setting the power switch to 

the forward or back on position. The green alert light 
will illuminate and an audio alert or brief vibration will 
indicate the unit has been turned on. The green alert 
light will remain on until the unit is turned off. 

When the detector is operating, it will detect metal 
only while it is in motion. Move the instrument within 
approximately one inch from the person (object) being 
inspected. A sound will be heard or vibration felt and the 
red alert light will illuminate whenever metal is detected. 
Operation is completely automatic. No "retuning" is 
ever necessary. All conductive metals will be detected, 
including ferrous, non-ferrous and stainless steel.

Audible Operation 

– Press the power switch forward and 

a clear alert signal will be heard, either through the 
speaker or through an optional earphone, whenever 
the metal detector detects metal. The forward-most red 
alert light will also appear upon detection of metal.

Silent Vibrating Operation –

 Press the power switch 

backward and the detector handle will vibrate whenever 
metal is detected, but no sound will be heard. The red 

alert light will always appear upon detection of metal.

NOTE: Do not affix metallic labels (or any 

material that might cause the detector to 
alarm) to the detection area of the metal 

detector. Doing so might cause an imbalance 
within the detection field and thereby reduce 
scanning effectiveness.

SERVICE

BATTERY REPLACEMENT

Slide back the battery cover (do not attempt to remove 
it), tilt the detector and battery will slip out. Replace with 
fresh battery. Because the battery cover will not slide 
back if the battery is inserted improperly, never force the 
cover. When the metal detector is to be stored more than 

30 days, remove the battery.

INTERNAL SENSITIVITY ADJUSTMENT

Some applications may require a sensitivity setting other 
than the nominal factory setting. This may be achieved 
by choosing an appropriate test target and utilizing the 
internal sensitivity adjustment as follows:

Turn on the metal detector. Roll back the grip cover 

just below the nameplate. Insert a small flat or 
Phillips screwdriver into the potentiometer located 
within the exposed hole. Rotate the potentiometer 
counterclockwise to decrease sensitivity, or rotate the 
potentiometer clockwise to increase sensitivity, until the 
desired detection of the test target is achieved.

An excessive sensitivity setting may result in unstable 

operation (chatter) and excessive detection of 
surrounding metal. 

NOTE: This sensitivity adjustment potentiometer 

is set to the nominal center (12 o'clock) position 
by the manufacturer.

CAUTION! Always verify that the detector is set 

to the desired sensitivity level by testing with 
appropriate targets any time the sensitivity 
adjustment is changed.

Содержание S-21664

Страница 1: ...be recharged or replaced AUDIO ALERT The speaker provides a clearly audible sound whenever metal is detected The audio alert sounds only when the power switch is pressed forward VIBRATING ALERT The vi...

Страница 2: ...rm to the detection area of the metal detector Doing so might cause an imbalance within the detection field and thereby reduce scanning effectiveness SERVICE BATTERY REPLACEMENT Slide back the battery...

Страница 3: ...with no operator adjustments required This ensures that the detector will be used at the proper operating level established for the particular security need Should nearby stationary metal objects floo...

Страница 4: ...ecargar o reemplazar ALERTA DE AUDIO La bocina proporciona una sonido claro y audible cuando se detecta un metal La alerta de audio suena nicamente cuando el interruptor se presiona hacia adelante ALE...

Страница 5: ...ecci n del aparato El hacerlo podr a causar un desequilibrio dentro del campo de detecci n y por lo tanto reducir la efectividad del escaneo SERVICIO REMPLAZO DE LA BATER A Deslice la cubierta de la b...

Страница 6: ...egura que el detector ser utilizado en un nivel apropiado establecido para la necesidad particular de seguridad En caso de que los objetos met licos estacionarios varillas de piso paredes met licas o...

Страница 7: ...ble et doit tre recharg e ou remplac e ALERTE SONORE Le haut parleur met un son audible chaque fois qu un m tal est d tect L alerte sonore ne se d clenche que lorsque l interrupteur d alimentation est...

Страница 8: ...ble d activer l alarme du d tecteur Cela pourrait provoquer un d s quilibre dans le champ de d tection et r duire ainsi l efficacit du balayage SERVICE REMPLACEMENT DE LA PILE Faites glisser le couver...

Страница 9: ...oit n cessaire Cela garantit que le d tecteur sera utilis au niveau de fonctionnement appropri tabli pour un besoin de s curit sp cifique Si des objets m talliques immobiles proximit barres d armature...

Отзывы: