Problem
Possible Cause
Remedy
The unit frosts
Unit is manual
Model B2015 is a
up.
defrost model.
manual defrost.
Refer to DEFROSTING.
High ambient
Defrost unit manually.
temperatures or
See DEFROSTING.
humidity.
Water is leaking
Water supply
Tighten fitting. See
out the back
connection leaking.
CONNECTING THE
of the unit.
WATER SUPPLY.
Ice cubes
Infrequent use of cubes.
Break apart cubes.
sticking together.
Noise during
Copper water supply
Carefully bend tubing
operation.
tubing contacting
away from cabinet and
internal components.
components.
Certain sounds
Soft sounds from the fan
are normal.
and water/dropping
sounds from the ice maker
will be heard.
No ice.
Bin arm locked in
Lower bin arm.
upright position.
No water to unit.
Turn on water or contact
plumber.
Not enough ice.
Ice cube size too
Set cube size smaller.
large.
See ADJUSTING ICE
CUBE SIZE.
Dirty condenser coils.
Clean condenser.
See MAINTENANCE.
Water leaks into
Water level set too
Set cube size smaller.
ice bucket.
high.
See ADJUSTING ICE
CUBE SIZE.
Fresh food section
Ice bucket not fully
Push ice bucket
on Combo units
inserted.
into place.
too cold.
Flap door not closed
Be sure Flap door is
correctly.
closed correctly.
Temperature control
Set control to warmer
set too cold.
setting (COUNTER-
CLOCKWISE)
.
Inaccurate temperature
Properly check tempera-
reading.
ture. See Page 17.
27