PAGE 15 OF 33
1219 IH-8105
APPLICATIONS CONTINUED
Method 2
1. Press the softkey
corresponding to the
PCS
icon to enter
the submenu for setting
the number of pieces.
(See Figure 47)
2. Press the softkey
corresponding to the
icon to edit the
PCS value using the
alphanumeric keypad.
(See Figure 48)
3. After editing, press the
softkey corresponding
to the
icon for
confirmation, and
then press the softkey
corresponding to the
Menu
User
icon to exit the submenu. (See Figure 49)
APPLICATION SETUP
The Application can be customized for various user
preferences.
1. Press the softkey
corresponding to the
icon to enter
Configuration. The
Configuration screen
is now displayed.
(See Figure 50)
2. Select the list item
and press the softkey
corresponding to the
icon to change the
setting as desired.
(See Figure 51)
3. To return to the Application home screen, press the
button corresponding to the
Menu
User
icon.
Figure 47
Figure 48
Figure 50
Figure 49
Figure 51
The Counting Configurations are defined below.
CONFIGURE ITEM
OPTION
DESCRIPTION
Auto Tare
Off
/On
Off:
Auto tare is turned off.
On: The first stable weight (>=5d) will be tared as a container automatically.
Accumulate
Off
/Automatic/Manual
Off:
The icon "
Σ
" does not display.
Manual: The softkey "
Σ
" displays. User can press the key to accumulate the stable weight.
Automatic: The icon "
Σ
" displays. The weight will be accumulated automatically.
NOTE: The load to be accumulated has to be >= 5d. The next
accumulation can only start once the pan is cleared.
When LFT is ON (no such limit when LFT is OFF or the approve mod is OIML),
a. Gross weight and net weight cannot be accumulated;
b. Gross 0 has to be reached before a new sample accumulation.
When LFT is OFF,
a. Gross weight and net weight can be accumulated;
b. A new sample can be accumulated after reaching gross 0 or net 0.
Auto Opt.
Off/
On
Off: Auto Opt. is off.
On:
The APW will be optimized automatically during count weighing.
Opt. Beep
Off/
On
Off: Opt. Beep is off.
On
: When the APW has to be optimized, the beeper will beep once.
APW Auto Save
Off/
On
Off: APW Auto Save is off.
On
: If the APW is derived from sampling, and a counting library is selected, the new APW
will be saved to library after optimized.
NOTE: It will be hidden when "Auto Opt." is off.
Internal Resolution
Off/
On
Off: Internal Resolution is off.
On
: During sampling or weighing, the internal resolution will be used.
Reference Size
10
The One Button Sampling PCS is from 0 to 999 the default is 10.
0: The One Button Sampling key will be hidden.
NOTE: Defaults settings are in bold.