USER GUIDE
Control Operation - Service 4
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
To access Relay Toggle
1. Press to select “Relay Toggle”.
2. Press .
3. Press and to scroll through each relay or DC
output.
4. Press
to
toggle.
To exit the Relay Toggle menu, press to select “Return
to Menu” and press to confirm.
Input Status
Input status displays the current state of each available
input.
To access Input Status
1. Press to select “Input Status”.
2. Press .
3. Press and to scroll through available
information.
To exit the Input Status menu, press to select “Return
to Menu” and press to confirm.
Outputs
Outputs is used to monitor the state of DC outputs.
To access Outputs
1. Press to select “Outputs”.
2. Press
3. Press and to scroll through available
information.
To exit the Outputs Status menu, press to select
“Return to Menu” and press to confirm.
F3
Condenser Fan (Not Used)
AC
L1
Cabinet Lighting
DC
L2
Cabinet Lighting (Not Used)
DC
WV
Water Valve
AC
Pump
Circulation Pump
AC
Harvest
Harvest
AC
ID
Description
States
Door
Door Switch
Open - Closed
IN2
Input 2 - Not Used
Open
Test Input
Factory Test Input
Open
Up
Select
Down
RETURN TO MENU
INPUT STATUS
DOOR OPEN
IN2 OPEN
ID
Description
States
Evap Fan
Evaporator Fan
0 - 100%
Condenser Fan
Condenser Fan
0 - 100%
Light
Interior Lighting
Off - Low - Med - High
Up
Select
Down
RETURN TO MENU
OUTPUTS
EVAP FAN=0%
CONDENSER FAN=0%