0509 IH-99
PAGE 5 OF 5
PREvENTIvE MAINTENANCE
• Weekly–remove cutting head and clean, and
look for missing roller rings. replace as needed.
• Monthly–remove blade spring and blades to
inspect cutter liners. Place one drop of silicone
oil on each liner, or replace if worn. Inspect feed
roller and blade for tape fragments or adhesive
buildup. Clean with alcohol.
TROUblESHOOTINg
OPErATING ISSUE
rECOMMENDATIONS
Motor does not drive.
Check that the power cord is plugged in.
Check that the power switch is turned on.
Tape does not cut.
Make sure the cutter unit is set properly and clean.
LED does not light.
Check that the power cord is plugged in.
Check that the power switch is turned on.
Tape does not feed.
Check if the tape is jammed at the roller or in the cutter unit.
Check that the tape is set properly.
Auto feed does not work.
Check that the sensor plug is plugged in.
Check that the sensor switch of cutter unit is on.
Check that the sensor part of the cutter unit is not stained.
Tape feeding does not stop.
Check that the tape is centered. If not, set the tape at the
center of the feed roller so that the sensor will see the tape.
When problems occur, carry out the following procedures. If the tape dispenser does not operate normally after