U-Line H-8816 Скачать руководство пользователя страница 2

PAGE 2 OF 18 

0720 IH-8816

FCC COMPLIANCE

This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions: 

1.  This device may not cause harmful interference.

2.  This device must accept any interference received, 

including interference that may cause undesired 

operation.

FCC STATEMENT

This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to 

Part 15 of the FCC Rules. These limits are designed 

to provide reasonable protection against harmful 

interference in a residential installation. 

CAUTION! This equipment generates, uses and 
can radiate radio frequency energy and, if 

not installed and used in accordance with the 
instructions, may cause harmful interference to 
radio communications. 

NOTE: There is no guarantee that interference 
will not occur in a particular installation. 

If this equipment does cause harmful interference to 

radio or television reception, which can be determined 

by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or 

more of the following measures:

•  Re-orient or relocate the receiving antenna.

•  Increase the space between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit 

different from the circuit the receiver is connected to.

•  Consult the dealer or an experienced radio/TV 

technician for help. 

CANADA, INDUSTRY CANADA (IC) NOTICES

Class B digital circuitry of this device complies with 

Canadian ICES-003. This device complies with Industry 

Canada license-exempt RSS standard(s). Operation is 

subject to the following two conditions: (1) this device 

may not cause interference, and (2) this device must 

accept any interference, including interference that 

may cause undesired operation of the device.

Under Industry Canada regulations, the radio 

transmitter(s) in this device may only operate using 

an antenna of a type and maximum (or lesser) gain 

approved for the transmitter by Industry Canada. To 

reduce potential radio interference to other users, the 

antenna type and its gain should be so chosen that the 

equivalent isotropically radiated power (e.i.r.p.) is not 

more than that necessary for successful communication.

WARNING! Indicates a potentially hazardous 

situation or an unintended use which, if not 

avoided, will result in death or serious injury.

CAUTION! Indicates a potentially hazardous 

situation or an unintended use which, if not 

avoided, may result in minor injury and/

or appreciable material, financial and 

environmental damage.

Important paragraphs that must be adhered to in 

practice, as they enable the product to be used 
in a technically correct and efficient manner.

BATTERY SAFETY

WARNING! Batteries can explode or leak and 
can cause injury or fire. To reduce this risk:

•  ALWAYS follow all instructions and warnings on 

the battery label and package.

• DO NOT short any battery terminals.

• DO NOT charge alkaline batteries.

•  DO NOT mix old and new batteries. Replace 

all of them at the same time with new 

batteries of the same brand and type. 

• DO NOT mix battery chemistries.

• DO NOT dispose of batteries in fire.

• ALWAYS keep batteries out of reach of children.

•  ALWAYS remove batteries if the device will not 

be used for several months.

NOTE: Ensure that the correct batteries as 
recommended are used.

NOTE: Ensure the batteries are inserted in the 

correct manner, with the correct polarity.  
(See Figure 1)

SAFETY CONTINUED

1

2

3

AAA

Figure 1

Содержание H-8816

Страница 1: ...instructions and product manual before using this product The person responsible for the product must ensure that all users understand and adhere to these instructions WARNING The following label information is placed on your laser tool to inform you of the laser class for your convenience and safety The meter emits a visible laser beam The laser beam emitted is Laser Class 2 per IEC 60825 1 and c...

Страница 2: ...onditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Under Industry Canada regulations the radio transmitter s in this device may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference...

Страница 3: ...HANGE MEASUREMENT REFERENCE POINT SINGLE MEASUREMENT CONTINUOUS MEASUREMENT FUNCTION ADDITION SUBTRACTION UNITS OPERATION SAFETY CONTINUED Default measurement is from the rear of the device Measurement is from the front of the device Press for ON Aim laser at target Press to activate laser Start continuous measurement Start continuous capture measurement last value 2 Seconds Aim laser at target 2 ...

Страница 4: ...T Capture the room or space HOME CENTE R SAVE SOLD EXPORT PDF DXF JPG Save share floorplans Step 5 Save share floorplans Verify room space measurements Verify room space measurements Press x 1 to select area measurement Download DeWalt Tool Connect app to Smartphone or tablet Press to measure distance 1 Press to measure distance 2 Press x 2 to select volume measurement Press to measure distance 1 ...

Страница 5: ... Auto Power Switch Off After 90 seconds Continuous Measuring Yes Area Volume Yes Battery Life Up to 3 000 measurements 2 500 with Bluetooth Dimensions H x D x W 4 72 x 1 91 x 1 02 120 x 48 5 x 26 mm Weight with Batteries 3 21 oz 100 g Storage Temperature Range 14 to 140ºF 10 to 60ºC Operating Temperature Range 32 to 104ºF 0 to 40ºC Under favorable conditions good target surface room temperature up...

Страница 6: ...e 302 Temperature too low Allow device to warm up to operating temperature 401 Hardware error Switch on off device several times 402 Unknown error Contact Uline Customer Service If the troubleshooting section does not resolve or describe your problem contact Uline Customer Service at 1 800 295 5510 π CHICAGO ATLANTA DALLAS LOS ANGELES MINNEAPOLIS NYC PHILA SEATTLE MEXICO CANADA 1 800 295 5510 ulin...

Страница 7: ...cia 9 Área Volumen 10 Activación del Bluetooth FUNCIONES DE CONTROL SEGURIDAD ADVERTENCIA Lea con atención las instrucciones de seguridad y el manual del producto antes de usar este producto La persona responsable del product deberá asegurarse de que todos los usuarios del mismo comprendan y cumplan estas instrucciones de seguridad ADVERTENCIA La siguiente etiqueta de información está colocada en ...

Страница 8: ... causar interferencias y 2 este dispositivo deberá aceptar cualquier interferencia incluyendo aquellas interferencias que puedan ocasionar un funcionamiento no deseado del dispositivo De acuerdo con la normativa de Industry Canada el transmisor de radio de este dispositivo solo podrá utilizarse usando una antena de un tipo y alcance máximo o menor aprobada para el transmisor por Industry Canada Pa...

Страница 9: ...AR UNIDADES FUNCIONAMIENTO CONTINUACIÓN DE MEDIDAS DE SEGURIDAD La medición se realiza por defecto desde la parte posterior del dispositivo La medición se realiza desde la parte delantera del dispositivo Presione durante 2 segundos para cambiar la medición de referencia de la parte posterior a la delantera del dispositivo Presione para ENCENDER Inicie la Medición Continua Apunte el láser Hacia el ...

Страница 10: ...XPORTACIÓN PDF DXF JPG GUARDAR Paso 4 Paso 3 Paso 1 Paso 5 Paso 2 Presione 1 ves para Seleccionar la Medición del Área Descargue la aplicacion DeWalt Tool Connect en su smartphone o tableta Verifique las mediciónes de la habitación espacio Guardar Compartir planos de suelo Vinclue con el dispositivo a través de la aplicación DeWalt Tool Connect Capture su habitación o espacio Presione para Medir l...

Страница 11: ...agado Automático Después de 90 segundos Medición Continua Sí Área Volumen Sí Vida útil de la Batería Up to 3 000 mediciones 2 500 con Bluetooth Dimensiones Altura x Profundidad x Ancho 120 x 48 5 x 26 mm 4 72 x 1 91 x 1 02 Peso con Baterías 3 2102 oz 100 g Rango de Temperatura de Almacenamiento 10 a 60ºC 14 a 140ºF Rango de Temperatura de Funcionamiento 0 a 40ºC 32 a 104ºF En condiciones favorable...

Страница 12: ... 302 Temperatura demasiado baja Permita que el dispositivo se caliente hasta alcanzar la temperatura de funcionamiento 401 Error de hardware Encienda apague el dispositivo varias veces 402 Error desconocido Llame a Servicio a Clientes de Uline Si la sección de solución de problemas no resuelve su problema llame a la línea de Servicio a Clientes de Uline al 800 295 5510 π CHICAGO ATLANTA DALLAS LOS...

Страница 13: ...NCTIONS DES COMMANDES SÉCURITÉ AVERTISSEMENT Lisez attentivement les consignes de sécurité et le manuel avant d utiliser ce produit La personne responsable de produit doit s assurer que tous les utilisateurs comprennent et respectent ces instructions AVERTISSEMENT L étiquette suivante est apposée sur votre télémètre pour votre sécurité et commodité afin de vous renseigner sur la classe du laser Le...

Страница 14: ...ouillage et 2 doit accepter tout brouillage même celui susceptible d en compromettre le fonctionnement En vertu des règlements d Industrie Canada l émetteur radio de cet appareil peut fonctionner uniquement à l aide d un type d antenne et d un gain maximum ou moindre approuvés pour l émetteur par Industrie Canada Pour réduire le brouillage radioélectrique potentiel pour les autres utilisateurs le ...

Страница 15: ...DE MESURE DE RÉFÉRENCE MESURE UNIQUE MESURE EN CONTINU FONCTION ADDITION SOUSTRACTION UNITÉS FONCTIONNEMENT SÉCURITÉ SUITE La mesure par défault se fait par l arrierè de l appareil Appuyez pendant 2 secondes pour faire passer la mesure de référence de l arriére à l avant de l appareil Le mesure se fait par l avant de l appareil Appuyez pour allumer Appuyez pour mesurer Pointer la cible avec le las...

Страница 16: ...ape 3 Étape 1 Étape 5 Étape 2 Appuyez 1 fois pour sélectionner la mesure de l aire Appuyez 2 fois pour sélectionner la mesure du volume Appuyez pou mesure la distance 1 Appuyez pou mesure la distance 2 Appuyez pou mesure la distance 3 Télécharges le l application DeWalt Tool Connect Floorplan sur votre téléphone ou tablette Jumele à l appareil via l application DeWalt Tool Connect Saisissez votre ...

Страница 17: ...es Arrêt automatique Après 90 secondes Mesure continue Oui Aire de volume Oui Durée de vie des piles Jusqu à 3 000 mesures 2 500 avec Bluetooth Dimensions haut x prof x larg 120 x 48 6 x 26 mm 4 72 x 1 91 x 1 02 po Poids avec piles 100 g 3 2102 oz Plage de température d entreposage 10 à 60 ºC 14 à 140 ºF Plage de température de fonctionnement 0 à 40 ºC 32 à 104 ºF Jusqu à 10 m 33 pi dans des condi...

Страница 18: ...température est trop élevée Laissez l appareil refroidir à la température de fonctionnement 302 La température est trop basse Laissez l appareil se réchauffer à la température de fonctionnement 401 Erreur de matériel Allumez éteignez l appareil à plusieurs reprises 402 Erreur inconnue Communiquez avec le service à la clientèle de Uline DÉPANNAGE SUITE π CHICAGO ATLANTA DALLAS LOS ANGELES MINNEAPOL...

Отзывы: