MAINTENANCE CONTINUED
VACUUM MOTOR INTAKE FILTERS
1. Turn off and unplug vacuum cleaner.
2. Position handle in operating position.
3. Open vacuum lid.
4. Remove clamp with screwdriver to gain access to
filter.
5. Remove plastic cap covering the motor.
6. Remove plastic retainer in cap.
7. Replace filters in their original positions.
(See Figure 11)
8. Reinstall plastic retainer in cap.
9. Reinstall cap onto motors.
10. Reinstall clamp.
NOTE: Replace the vacuum motor filters every
six months.
Figure 11
SPECIFICATIONS
Model
93030
Voltage / Frequency
120 V / 60 Hz
Vacuum Motor Rating
1512 W
Brush Motor Rating
1/4 hp
Total Power Consumption
14 A
Bag capacity – Dry
45.5 qt.
Airflow
224 cfm
Vacuum – Water Lift at Sealed Orifice
71 in.
Filtration – HEPA
99.97% @ 0.3 micron
Vibration at Controls
< 2.5 m/s
2
Brush Width
30 in.
Cable Length
75 ft.
Weight (Including Cord)
74 lbs.
Noise level
69.9 dB(A)
Construction Class
I
Protection
IP20
Machine Dimensions
Folded: 36 x 31 x 19"
Operating Position
36 x 31 x 42"
Filters