PAGE 7 OF 27
0120 IH-7241
Call Uline Customer Service at
1-800-295-5510.
Seal wire.
Temperature not reached.
Seal jaw is not closed.
Only possible if a micro switch is
mounted.
Transport failure.
Transport motor overload.
CHANGING THE BELTS
ERROR CODES
1. Remove the blue covers on
both the top and bottom
sealing units using included
Allen key. Ensure the top
sealing unit is unlocked.
(See Figure 8)
2. Push the top sealing unit to
the left.
3. Remove the Teflon
®
belt
while applying upward
pressure to the top sealing
unit and replace with a new
Teflon
®
belt. (See Figure 9)
4. Repeat steps 2 and 3 with the bottom sealing unit.
5. Reattach the blue covers
using the included Allen key
and turn the locking knob
counterclockwise to lock
the top sealing unit.
(See Figure 10)
Teflon Belt
ERROR 20
Calibration out of range
Calibrate seal wire
Turn off and on
ERROR 30
Seal jaw is not closed
Close jaw
Press start to release
ERROR 21
Seal wire
Check connection
Turn off and on
ERROR 31
Transport failure
Check film transport
Press start to release
ERROR 22
Temperature not reached
Check seal system
Turn off and on
ERROR 32
Transport motor overload
Check film transport
Press start to release
Figure 8
Figure 10
Figure 9