PAGE 3 OF 9
0821 IH-7206
1. To apply the proper amount of tension for proper
label feeding and detection, loosen brush wing
screw and press down to increase tension, then
tighten screw. (See Figure 6)
2. Loosen wing screw, then adjust sensor plate.
3. Point sensor toward the top edge of the label; then,
tighten wing screw to secure sensor in place.
(See Figures 7 and 8)
4. Connect power cord and press power switch to turn
on. (See Figure 9)
Figure 6
Brush Wing
Screw
Figure 9
Power Switch
Figure 7
Sensor
Wing Screw
Figure 8
Incorrect
Sensor sees beyond
label (Will not stop)
Sensor sees strip plate
(Will not feed)
Sensor sees front edge of label
ADJUSTMENTS
1-800-295-5510