0114 IH-3582

TROUBLESHOOTING

OPERATING ISSUE

CAUSES

Swirls on the floor after scrubbing.

1.  Area not properly swept – debris in pad or brush.

2.  Incorrect solution. 

3.  Improper pad or brush for the job.

4.  Moving the machine too fast.

Swirls on the floor after dry buffing. 

1.  Moving the machine too fast.

2.  Floor finish too soft.

3.  Area not properly swept – debris in pad or brush.

4.  Improper pad or brush for the job.

Circles on the floor.

1.  Machine standing still while the brush or pad is running.

Floor finish removed.

1.  Improper pad – too aggressive.

2.  Solution too strong.

Machine wobbles during operation.

1.  Defective pad – one side is more dense than the other.

2.  Machine left sitting on brush or pad for extended period of time 

causing bristles or pad to "take a set."

3.  Pad not "seated" properly into pad holder bristles.

4.  Warped block on brush or padholder; replace.

Machine does not turn on.

1.  Check plug for proper connection on machine and at wall 

outlet.

2.  Check building circuit breaker.

3.  Call Uline Customer Service at 1-800-295-5510 for repair or 

service. Please have serial number ready. 