0615 IH-1607
PAGE 5 OF 6
OPERATION
POWER ON/OFF
1. Press the On/Off key for two seconds to turn the scale
on or off.
2. When turning on, the indicator will show
000000-999999 before entering weighing mode.
3. Check that the LED/LCD display and the status lights
are working properly.
ZERO
INITIAL ZERO SETTING
When turning the scale on, if the weight on the display
indicator is within the initial zero tolerance the indicator
will show zero.
MANUAL ZERO SETTING
1. Wait for the scale to stabilize.
2. Press the Zero key. The display will show zero weight.
TARE
1. Press the TARE key.
2. The indicator will show the net weight. The Net and
Tare function lights will light up.
3. Press the TARE key. Zero the weight.
4. The indicator will display the gross weight.
ACCUMULATION
1. Zero the weight. Load weight until the scale stabilizes.
2. Press the Total key to enter accumulation mode.
3. Total function light will light up. Display will read
"n 001" then will display the loaded weight.
4. Unload the weight. Zero the weight. Load the
second weight until the scale stabilizes.
5. Press the Total key. The display will read "n002" then
display the second loaded weight.
6. Repeat a maximum of 999 times.
CHECK THE ACCUMULATION
1. Press and hold the Print key. Press the Total key.
2. Display will read "n**" then will show total weight.
NOTE: There are 8 digits total. The display shows
the first 4 digits, then the last 4 digits.
For example, when the first 4 digits displayed
are, "0012" and the last 4 digits displayed are
"34,56" the weight is "1234.56."
EXIT ACCUMULATION
1. When the indicator shows the last 4 digits, press and
hold the Total key. The indicator will read "clr n."
2. Press the Print key to exit it. If you want to clear the
total weight, press the Zero or Tare key. The indicator
will read "clr y."
3. Press the Print key to clear the total weight and exit
accumulating mode.
1. If the weight is stable, connect the scale to the
printer.
2. Press the Print key.
NOTE: While in tare mode, print with tare. If the
scale shows a negative weight, printing is not
allowed.
COUNT
1. At weighing mode, load the weight on the platform.
2. Press the Count key. The indicator will read "PCS 0."
3. Press the Zero key. Enter the quantity. Press the Print
key to enter.
4. Load the weight on the scale. The indicator will
display the count.
5. Press the Count key to return to weighing mode.
6. To weigh different weights, at weighing mode put
the item on the scale and press the Count key. The
indicator will read "0."
7. Press and hold the Count key. Press the On/Off key.
The indicator will show "PCS 0."
8. Press the Zero key and input the sample quantity.
9. Press the Print key to enter. Repeat steps 2 and 3.