background image

CLR2060 — Clear Ice Maker

www.U-LineService.com

2

02/2005

Contents

Cut-Out Dimensions   . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

Product Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

4

Door Swing/Clearances Information   . . . . . . . . . . . . . . 

4

Reversing the Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

 

5

Other Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 

6

Side-By-Side Installation Instructions  . . . . . . . . . . . . . . 

6

Custom 1/4'' Door Panel Insert  . . . . . . . . . . . . . . . . . . . 

7

Full Overlay Door Panel . . . . . . . . . . . . . . . . . . . . . . . . . 

8

Checking Door Alignment   . . . . . . . . . . . . . . . . . . . . . . 

11

Adjusting Door Alignment  . . . . . . . . . . . . . . . . . . . . . . 

11

Drain Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

Water Supply Connection  . . . . . . . . . . . . . . . . . . . . . . . 

15

Electrical Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . 

16

Leveling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 

16

Installation Tip  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

17

Installation of the CLR2060 . . . . . . . . . . . . . . . . . . . . . . 

17

Installation Troubleshooting . . . . . . . . . . . . . . . . . . . . . 

18

Initial Start-Up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

18

Start-Up Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . 

19

Service Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

20

IMPORTANT

PLEASE READ all instructions completely before 
attempting to install or operate the unit. 

• This unit requires connection to the water supply. 

Improper hook-up can result in substantial property 
damage! If you are unsure of your ability to safely 
connect the water supply to the unit, consult a licensed 
plumber for assistance.

• This unit requires connection to a drain. Improper 

connection can result in substantial property damage! 
If you are unsure of your ability to safely connect the 
unit to a drain, consult a licensed plumber for 
assistance.

• This unit requires connection to a grounded (three-

prong), polarized receptacle that has been placed by a 
qualified electrician in accordance with applicable 
electrical codes.

Safety Alert Definitions

Safety items throughout this guide are labeled with a 
Danger, Warning or Caution based on the risk type:

DANGER

Danger means that failure to follow this safety 
statement will result in severe personal injury or 
death. 

WARNING

Warning means that failure to follow this safety 
statement could result in serious personal injury, 
or death.

CAUTION

Caution means that failure to follow this safety statement 
may result in minor or moderate personal injury, property 
or equipment damage.

1 Follow Safety Precautions

Содержание ECHELON CLR2060

Страница 1: ...eService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CLR2060 Clear Ice Maker Installat...

Страница 2: ...of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires connection to a drain Improper connection can result in substantial propert...

Страница 3: ...User Manual and this Installation Guide in a safe place for future reference Your unit is Black White or Stainless Steel Black and White units have a reversible door with a slightly contoured handle...

Страница 4: ...acent cabinet doors in certain installations you may need to alter the wall just behind the drain connection on the unit to accommodate the drain The actual amount of alteration will be determined by...

Страница 5: ...mount on opposite side BOTTOM see Figure 7 4 Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge see Figure 8 5 Remove existing bottom hinge...

Страница 6: ...tdoor use by UL The unit must not be located near heat generating equipment or in direct sunlight Side By Side Installation Instructions For a complete refreshment center install your CLR2060 Clear Ic...

Страница 7: ...ation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin 7 64 Allen wrench or Phillips screwdriver depending on your unit s...

Страница 8: ...k corner of overlay panel Refer to Figure 16 for exact specifications Route notch in top corner of overlay panel as shown see Top and Side Views Top of notch is entire depth of panel front to back Wid...

Страница 9: ...4 Remove the top handle and discard This handle will be replaced with the Modified Handle included in the Full Overlay Door Panel Kit 5 Remove the two screws located on both sides of the lower handle...

Страница 10: ...wo screws removed in Step 5 under Removing Existing Door 3 Starting at the corners and working toward the center push the door gasket back into place Installing the Door 1 Remove the existing hinges f...

Страница 11: ...gned the door should be 1 8 below the top of the unit s cabinet NOT flush with the top see Figure 26 1 Compare the top edge of the door to the top edge of the cabinet 2 If the door edge is 1 8 below a...

Страница 12: ...actor Failure to follow recommendations and instructions may result in damage and or harm Drain Connection IMPORTANT Drain can NOT be located directly below unit Unit has a solid base that will not al...

Страница 13: ...ons requiring a Drain Pump If you need to install a P60 Drain Pump into your unit see Locally Installed Drain Pump on Page 14 IMPORTANT Before installing your U Line CLR2060 with Factory Installed U L...

Страница 14: ...e back of the unit to a 5 8 inch OD rigid tube using a worm clamp 2 Attach the other end of the rigid tube to your 5 8 inch ID drain line with a worm clamp 3 Insulate the drain line if necessary to pr...

Страница 15: ...ation U Line recommends the use of copper tubing for installation To connect to water supply 1 Install the 1 4 inch OD copper water line from the main water source see Figure 37 2 Locate the compressi...

Страница 16: ...e more easily serviced with self diagnostics without disturbing your installation WARNING SHOCK HAZARD Electrical Grounding Required Never remove the round grounding prong from the plug and never use...

Страница 17: ...feet This allows the unit to be gently tipped into the opening Readjust the front feet to level the unit after it is correctly positioned in the opening Installation of the CLR2060 1 Open the water su...

Страница 18: ...to align with the rest of the cabinet doors but the unit has crept forward Solution A First make sure that the electrical cord and water supply line are not obstructing the installation If they are no...

Страница 19: ...leshooting Problem Q Unit does not appear to turn on when switch is set to ICE Solution A Remember that the compressor will not operate until the water has been filling for about 3 minutes Make sure u...

Страница 20: ...U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact the d...

Отзывы: