background image

QUICK START GUIDE

DISPENSERS •   DE224D (115v) •   2 Tap Beer

30662_C

Содержание DE224D

Страница 1: ...QUICK START GUIDE DISPENSERS DE224D 115v 2 Tap Beer 30662_C ...

Страница 2: ...are available worldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspecte...

Страница 3: ...ur product For more details see the complete User Guide Service Manual on u line com CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Door Swing 5 Door Adjustments 6 General Installation 8 Control Operation 15 First Use 15 Airflow Product oading 16 Cleaning 186 Warranty 20 3 ...

Страница 4: ...afe for regular use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in th User Guide Do not damage the refrigerant circuit Service must be done by factory authorized service personnel Any parts shall be replaced with like components Failure to comply could increase the risk of possible ignition due to incorrect parts or im...

Страница 5: ...onnect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit ...

Страница 6: ...ust the door 1 Gently pry off hinge c ver from top of unit 2 Loosen do not remove top and bottom hinge screws using a Philips screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is firmly in con act with cabinet all the way around the door no gaps 5 Tighten bottom hinge screws 6 Tighten top hinge screws and replace hinge cover REVERSING THE D...

Страница 7: ... a 1 4 socket 2 Remove corresponding screws on opposite side of cabinet On some models there may be a nut behind one or both screws on either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Install top hinge and door 1 Rotate door 180o and lift the door on to the bottom hinge 2 Install hinge that was used on the opposite side of the unit 3 Align edge o...

Страница 8: ...O2 tank CAUTION Safety and Warning WARNING CO2 can be dangerous Handle with care Never exceed 60 PSI Most draft beers are dispensed between 8 14 PSI and most stouts are dispensed at 30 14 PSI Pressures above 50 PSI will release the built in pressure relief Always connect CO2 tank to regulator Never connect the tank directly to a keg Ventilate area after CO2 leak If it becomes difficult to breathe ...

Страница 9: ...rigerator Note Save gasket and cap plug for conversion back to a standard refrigerator 2 Insert tap assembly tubing through the provided gasket and then all the way into the refrigerator 3 Insert and tighten four screws to secure tower to keg refrigerator 4 Install faucets onto the tower Line up teeth on the outside of the faucets with the teeth inside the shank 5 Screw the coupling nuts onto the ...

Страница 10: ...283 mm Front edge of drilled hole to front face of unit Beverage Tube Insulation Diagram A Diagram B Insulation USER GUIDE u line com General Installation Install Tower on Countertop see template at the end of this section Do not remove all the protective film on the s ainless exterior until the tower is installed 1 Use template to drill four mounting holes 2 Drill 2 3 4 diameter hole through coun...

Страница 11: ...allation 12 1 2 TO FRONT FACE OF REFRIGERATOR SEE DIAGRAM A PREVIOUS PAGE 7 1 2 TO SIDE OF REFRIGERATOR 1 4 HOLE 2 3 4 HOLE Template for Countertop Installation Note Verify template has printed true to scale double check hole dimensions and placement 1 Inch ...

Страница 12: ...h regulator to CO2 tank Hand tighten the coupling nut and then use an adjustable wrench for an additional quarter turn DO NOT OVER TIGHTEN 3 Attach and clamp CO2 tubing to tap couplers 2 Attach 5 16 CO2 tubing to regulator nipple and clamp into place If necessary make the tubing more pliable by heating the end in boiling water ...

Страница 13: ...included 1 Attach and clamp beverage tubing to tap couplers 2 Attach tap couplers to kegs Locate notch and rotate clockwise 1 4turn 3 Press down and rotate clockwise an additional 1 4turn 4 Open valve on CO2 tank and adjust regulator to desired pressure by turning the handle clockwise 1 4 turn 1 4 turn ...

Страница 14: ...ill start to pour Stop turning when you get the best flow rat This method should prevent your regulator from creeping If you are dispensing at altitude you will need to increase your output pressure by one pound for every 2 000 feet of elevation above sea level LEVELING INFORMATION 1 Use a level to confirm the unit is l vel Level should be placed along top edge and side edge as shown 2 If the unit...

Страница 15: ...d upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit to reach set points before loading To dispense cold coffe make sure the components are assembled according to the instructions in GENERAL INSTALLATION NOTICE First Use Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and hold for 5 seconds Unit will turn On or ...

Страница 16: ...steel surfaces Sanitize the unit when exposed to raw meat juice or human germs such as from a sneeze or being touched by someone who is ill Sanitizing the unit can also be part of regular cleaning routine Stainless Surfaces Stainless door panels handles and frames can discolor when exposed to chlorine gas pool chemicals saltwater or cleaners with bleach Keep your stainless unit looking new by clea...

Страница 17: ...eaning solution to flow through it Push base of coupler inward and rotate clockwise 6 Open cleaning pump 7 Empty one packet of cleaner into plastic jar and fill with cool wate Closed Pin Open 8 Reassemble pump Continued on next page Beverage Line and Faucet Cleaning Clean the system using a suitable solution designed for beer dispensing systems Beer cleaning kits are also available Solution and or...

Страница 18: ...r Tighten with faucet wrench 11 Pump all the solution through the beverage line 13 Rinse out and refill plastic jar with clean wate Pump all the water through the beverage line to rinse 14 Rinse all disassembled parts with clean water 15 Reassemble faucet and reconnect CO2 and beverage lines 12 Allow tap coupler and faucet to soak in drainage bucket and then use faucet brush to clean faucet Disass...

Страница 19: ... puncture the inner lining or damage the cooling unit DO NOT use any type of heater to defrost Using a heater to speed up defrosting can cause personal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring the unit must be remove...

Страница 20: ... improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U Line will provide either under these warranties or under any warranty arising by operation of law U Line will not be responsi...

Отзывы: