background image

Level & Install Unit

15

12 Level The Unit

Leveling Information

It is recommended that the unit is level.

1. Use a level to check 

the levelness of the 
unit from front to 
back and from side 
to side. Level should 
be placed along top 
edge and side edge 
as shown 

2. If the unit is not level, adjust the feet on the corners of the unit 

as necessary (not available in CO29 models).

3. Check the levelness after each adjustment and repeat the 

previous steps until the unit is level.

INSTALLATION TIP

If the room floor is higher than the floor in the cut-out opening, 
adjust the rear feet to achieve a total unit rear height of 1/8" less 
than the opening’s rear height. Shorten the unit height in the front 
by adjusting the front feet. This allows the unit to be gently tipped 
into the opening. Readjust the front feet to level the unit after it is 
correctly positioned in the opening.

1

Turn Foot to Adjust

13 Install the Unit

Installation 

1. Open the water supply valve in the main water source.

2. Plug in the power cord.

CLR2160 & CLRCO2175 Only

• Open the door and press the POWER icon. to turn the unit 

OFF. 

Note: If the unit is NOT turned OFF, water will immediately 
start flowing into the unit when it is first plugged into the 
electrical outlet. 

• Test the drain system by pouring one gallon of water into 

the ice bin. The water should drain freely and there should 
be no leakage.

All Models

3. Gently push the unit into position. Be careful not to kink the 

water supply line or entangle the electrical cord.

4. Re-check the leveling, from front to back and side to side. Make 

any necessary adjustments. The unit’s top surface should be 
approximately 1/8" below the counter top.

5. Remove the tape from the glass shelves and wipe out the inside 

of the unit with a clean, water-dampened cloth.

Relocating the Shelves

Both the glass shelves in the refrigerator and the inner door 
shelves can be moved to accommodate your bottles, cans and 
containers.

Glass Shelves on Right-Hand Hinge Units

• Open door fully, grasp shelf firmly, lift front edge slightly, and 

pull straight out.

• Choose new location and slide shelf onto the appropriate rib.

Glass Shelves on Left-Hand Hinge Units

• Pull shelf out about 6” to clear the wall’s molded protrusion.
• Tilt right-hand edge of shelf up.
• Keeping at this angle and hugging the right wall, pull the shelf 

out.

• Choose new location and insert over ribs, tilting right-hand 

edge up. Push in, then lower shelf onto ribs.

Door Shelves

• First pull shelf up at a 45° angle, then straight out (see Figure 

39).

• Choose new location and line up on bosses. First push straight 

in, then down at a 45° angle.

Содержание CLR2160

Страница 1: ... The Built In Undercounter Leader Since 1962 CLEAR ICE MODELS CLEAR ICE COMBO MODELS ICE COMBO MODELS U LINE COM CO1175 CO2175 CLR2160 CLRCO2175 INSTALL GUIDE CO29 ...

Страница 2: ...nment and Adjustment 6 Door Reversability 6 Reversing the door 6 Self Closing Doors Door Alignment and Adjustment 8 Door Reversability 8 Reversing the door 8 Door Panel Installation Custom 1 4 Thick Door Panel Insert 10 Door Panel Preparation 10 Panel Dimensions 10 Door Panel Installation 10 Prepare Power Supply Electrical Specifications 11 Receptacle Location 11 Prepare Plumbing Water Supply Conn...

Страница 3: ...ical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adaptor Altering cutting of power cord removal of power cord removal of power plug or direct wiring can cause serious injury fire and or loss of property and or life and will void the ...

Страница 4: ... Panel Kit Part number U OL2175B black units U OL2175W white units A complete water hook up kit is also available for purchase from your dealer Order U Line Part No WATERHOOKUP Exterior Cleaning Black and White Models Black and White surfaces may be cleaned with a mild detergent and warm water solution Do not use solvent based or abrasive cleaners Use a soft sponge and rinse with clean water Wipe ...

Страница 5: ...llations CLR2160 Series Follow the cut out drawing The 15 1 4 width allows 1 4 for ease in installation and removal of the unit 24 is the cabinet depth in most installations 8 24 Minimum 24 1 4 See Electrical Specifications for Power Supply 34 1 4 to 35 1 8 See Electrical Specifications for Power Supply 34 1 4 to 35 1 8 15 1 4 8 24 CO29 Series Follow the cut out drawing The 21 1 16 width allows 1 ...

Страница 6: ...3 16 34 3 16 15 15 Black and White Stainless Steel 23 1 4 3 7 8 23 1 4 3 15 16 Add 3 4 To Depth For Drain Line Clearance Add 3 4 To Depth For Drain Line Clearance CO1175 Series BLACK CO1175 23 5 16 34 3 16 24 Add 3 16 to Depth For Water Line Clearance 3 13 16 34 3 16 24 STAINLESS CO1175 23 1 16 Add 3 16 to Depth For Water Line Clearance 3 13 16 CO2175 Series 34 3 16 24 Black andWhite Stainless Ste...

Страница 7: ...ements The units are designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures and may also reduce the ice production rate for those models with ice makers If the ambient temperature is expected to drop below 45 F 7 C drain all water from the unit to prevent freezing damage which is not covered by the...

Страница 8: ...th black and white doors are field reversible Stainless steel models with glass doors without locks are field reversible Stainless steel models without glass doors must be ordered right or left hand hinged Reversing the door The Hinge hardware will be removed and reinstalled on the opposite side of the cabinet The hinge plate is flipped over when it is reinstalled on the opposite side of the cabin...

Страница 9: ...sure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was removed 8 Install new nameplate where the actuator assembly was removed 9 Install screws into holes on opposite side where the hinge was removed Replace nuts if used 1 1 2 3 4 Prepare door for reinstallation For black or white doors 1 Remove plastic h...

Страница 10: ... sets 3 Turn the door upside down and inspect the hinge plate mounting holes The plate has slotted mounting holes Loosen but do not remove the two hinge plate screws 1 4 If door edge opposite the hinges needs to move up move plate toward outside of door 2 If door edge needs to move down move plate toward inside of door 3 Repeat until top edge of door is parallel with top of cabinet and tighten scr...

Страница 11: ...er inserts as shown on the new bottom hinge 4 Remove existing bottom hinge Remove the existing bottom hinge three screws 2 Reinstall hinge to top opposite Install the hinge just removed from the bottom to the TOP opposite side of the cabinet three screws 2 Reinstall Hole Plugs Install plastic screw plugs three each top and bottom 3 into holes where hinge hardware was removed Prepare door for reins...

Страница 12: ... tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force Model Width Height CLRCO2175 23 1 32 27 11 16 CLR2160 14 1 32 27 11 16 CO1175 22 15 16 26 15 16 CO29 19 13 16 21 13 32 CO2175 23 1 32 27 11 16 3 Remove the two outside screws holding door handle Slightly separa...

Страница 13: ...been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended GFCI ground fault circuit interrupter is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping H...

Страница 14: ...en using the two wrenches Drain Connection CLR2160 CLRCO2175 IMPORTANT IMPORTANT Drain can NOT be located directly below unit Unit has a solid base that will not allow the unit to drain below itself We strongly recommend the use of a U Line drain kit for both gravity pump installations A complete drain kit containing all the items needed to connect your unit are available from your dealer Part No ...

Страница 15: ...er cabinet or attempt to touch any components except the discharge tube during testing 4 Check that the clamps and hose connections are tight at the following areas Discharge tube A Drain tube B Vent tube C 5 Place a suitable container beneath the pump s discharge tube The bucket must be able to hold a minimum of one gallon 6 Plug the ice maker power cord into a properly grounded polarized electri...

Страница 16: ...e event of a pump failure It must have an operating temperature range of 50 F to 110 F 10 C to 40 C IMPORTANT IMPORTANT In the event of a power outage restricted drain or pump failure the failure to use the U Line P60 drain pump or a pump with the above listed specifications could result in substantial water leakage and pooling with severe and costly water damage and related consequential damages ...

Страница 17: ...rst plugged into the electrical outlet Test the drain system by pouring one gallon of water into the ice bin The water should drain freely and there should be no leakage All Models 3 Gently push the unit into position Be careful not to kink the water supply line or entangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top...

Страница 18: ...lution A The hinges should be self closing when the door is open approximately 8 If this is not the case make sure the closers at the bottom of the hinge pin are clean greased and installed correctly Also re check leveling from front to back of the unit and readjust if necessary Make sure that pivot plate is installed correctly Problem Q The custom overlay door was designed to align with the rest ...

Страница 19: ... today The Milwaukee Wisconsin based family operated business provides continuity and vision from which innovations continue to be born Going forward U Line will continue offering best in class products that build on the company s numerous pat ents and world firsts to guide the undercounter industry in realizing its unlimited potential U LINE COM GENERAL INQUIRIES U Line Corporation P O Box 245040...

Отзывы: