U-Line Electrical / Plumbing Specfications

12

P

CAUTION

Plumbing installation must observe all state and local 

codes. All water and drain connections MUST BE made by 

a licensed/qualified plumbing contractor. Failure to follow 

recommendations and instructions may result in damage 

and/or harm.

Water Supply Connection

When connecting the water supply, follow these guidelines:

• Review the local plumbing codes before you install the unit.
• Connect to the cold water supply.
• The water pressure should be between 20 and 120 psi.
• The water line MUST have a shut-off valve in the 1/4” O.D. 

supply line.

• Leave approximately 8’ of water line to be coiled behind the 

appliance. The water line should be looped into 2 coils. This 
will allow the unit to be removed for cleaning and servicing. 
However, make certain that the tubing is not pinched or 
damaged during installation.

IMPORTANT

IMPORTANT

U-Line requires the use of copper tubing for installation. 
Do not use any plastic water supply line. The line is under 
pressure at all times. Plastic may crack or rupture with 
age and cause water damage to your home.

To connect to water supply:

1. Locate the desired cold 

water supply location. Attach 
a 1/4” copper line to this 
location and route the tubing 
to the appliance. Leave 
approximately 8’ of water line 
to be coiled behind the 
appliance. The water line 
should be looped into 2 coils. 
This will allow the line to flex 
when removing the unit for 
cleaning and servicing.

2. Locate the U-Line supplied 

garden hose fitting. Ensure the 
end of the copper tubing has 
been cut straight and free of 
burrs. Slide the compression 
nut and ferrule onto the 
copper tubing as shown. Push 
the assembly completely into 
the garden hose fitting and 
tighten using the two 
wrenches. 

Drain Connection (CLR2160 CLRCO2175)

IMPORTANT

IMPORTANT

• Drain can NOT be located directly below unit. Unit has 

a solid base that will not allow the unit to drain below 
itself.

• We strongly recommend the use of a U-Line drain kit 

for both gravity & pump installations. A complete drain 

kit containing all the items needed to connect your unit 

are available from your dealer. Part No. U-

CLRDRAINKIT.

• Longer drain connections may require additional drain 

hose lengths. Additional drain line can be purchased 

from your dealer or directly from McMaster-Carr. 

(McMaster-Carr # 52375K35)

The CLR2160 or CLRCO2175 can be installed using a Gravity 
Drain, a Factory-Installed Drain Pump (U-Line P60) or a Locally-
Installed (U-Line P60) Drain Pump. Drain lines must have a 5/8” 
inside diameter. The floor drain must be large enough to 
accommodate drainage from all attached drains.

Follow these guidelines when installing drain lines to prevent water 
from flowing back into the ice maker storage bin and/or potentially 
flowing onto the floor, causing water damage:

Gravity Drain

A Gravity Drain may be used if:

• Drain line has at least a 1-inch drop per 48 inches of run (1/4 

inch per foot).

• Drain line does not create traps 

or created traps are vented.

If using a Gravity Drain:

1. Slide 2 hose clamps onto the 

drain connection on the rear of 
the appliance.

2. Insert the barbed fitting halfway 

into this connection.

3. On the other end of this barbed 

fitting attach the 5/8” braided 
tubing.

4. Slide a clamp on each side of the 

barbed fitting as shown (see 
Figure 39).

5. Insulate the drain line, if necessary to prevent condensation.

11 Prepare Plumbing

9/16" Wrench

1/4" Copper Water

Supply Line

7/16" Wrench

From Water  Supply

to Ice Maker

Normal

Proper Drain

With Trap

Poor Drainage, Water Will Back Up

With Trap and Vent

Proper Drain

Drain Fitting from

Back of Unit

Worm Clamps

Drain Line

5/8" x 5/8"

Barb Connector

ULIN_S_0166b2_A

Содержание CLR2160

Страница 1: ... The Built In Undercounter Leader Since 1962 CLEAR ICE MODELS CLEAR ICE COMBO MODELS ICE COMBO MODELS U LINE COM CO1175 CO2175 CLR2160 CLRCO2175 INSTALL GUIDE CO29 ...

Страница 2: ...nment and Adjustment 6 Door Reversability 6 Reversing the door 6 Self Closing Doors Door Alignment and Adjustment 8 Door Reversability 8 Reversing the door 8 Door Panel Installation Custom 1 4 Thick Door Panel Insert 10 Door Panel Preparation 10 Panel Dimensions 10 Door Panel Installation 10 Prepare Power Supply Electrical Specifications 11 Receptacle Location 11 Prepare Plumbing Water Supply Conn...

Страница 3: ...ical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adaptor Altering cutting of power cord removal of power cord removal of power plug or direct wiring can cause serious injury fire and or loss of property and or life and will void the ...

Страница 4: ... Panel Kit Part number U OL2175B black units U OL2175W white units A complete water hook up kit is also available for purchase from your dealer Order U Line Part No WATERHOOKUP Exterior Cleaning Black and White Models Black and White surfaces may be cleaned with a mild detergent and warm water solution Do not use solvent based or abrasive cleaners Use a soft sponge and rinse with clean water Wipe ...

Страница 5: ...llations CLR2160 Series Follow the cut out drawing The 15 1 4 width allows 1 4 for ease in installation and removal of the unit 24 is the cabinet depth in most installations 8 24 Minimum 24 1 4 See Electrical Specifications for Power Supply 34 1 4 to 35 1 8 See Electrical Specifications for Power Supply 34 1 4 to 35 1 8 15 1 4 8 24 CO29 Series Follow the cut out drawing The 21 1 16 width allows 1 ...

Страница 6: ...3 16 34 3 16 15 15 Black and White Stainless Steel 23 1 4 3 7 8 23 1 4 3 15 16 Add 3 4 To Depth For Drain Line Clearance Add 3 4 To Depth For Drain Line Clearance CO1175 Series BLACK CO1175 23 5 16 34 3 16 24 Add 3 16 to Depth For Water Line Clearance 3 13 16 34 3 16 24 STAINLESS CO1175 23 1 16 Add 3 16 to Depth For Water Line Clearance 3 13 16 CO2175 Series 34 3 16 24 Black andWhite Stainless Ste...

Страница 7: ...ements The units are designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures and may also reduce the ice production rate for those models with ice makers If the ambient temperature is expected to drop below 45 F 7 C drain all water from the unit to prevent freezing damage which is not covered by the...

Страница 8: ...th black and white doors are field reversible Stainless steel models with glass doors without locks are field reversible Stainless steel models without glass doors must be ordered right or left hand hinged Reversing the door The Hinge hardware will be removed and reinstalled on the opposite side of the cabinet The hinge plate is flipped over when it is reinstalled on the opposite side of the cabin...

Страница 9: ...sure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was removed 8 Install new nameplate where the actuator assembly was removed 9 Install screws into holes on opposite side where the hinge was removed Replace nuts if used 1 1 2 3 4 Prepare door for reinstallation For black or white doors 1 Remove plastic h...

Страница 10: ... sets 3 Turn the door upside down and inspect the hinge plate mounting holes The plate has slotted mounting holes Loosen but do not remove the two hinge plate screws 1 4 If door edge opposite the hinges needs to move up move plate toward outside of door 2 If door edge needs to move down move plate toward inside of door 3 Repeat until top edge of door is parallel with top of cabinet and tighten scr...

Страница 11: ...er inserts as shown on the new bottom hinge 4 Remove existing bottom hinge Remove the existing bottom hinge three screws 2 Reinstall hinge to top opposite Install the hinge just removed from the bottom to the TOP opposite side of the cabinet three screws 2 Reinstall Hole Plugs Install plastic screw plugs three each top and bottom 3 into holes where hinge hardware was removed Prepare door for reins...

Страница 12: ... tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force Model Width Height CLRCO2175 23 1 32 27 11 16 CLR2160 14 1 32 27 11 16 CO1175 22 15 16 26 15 16 CO29 19 13 16 21 13 32 CO2175 23 1 32 27 11 16 3 Remove the two outside screws holding door handle Slightly separa...

Страница 13: ...been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended GFCI ground fault circuit interrupter is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping H...

Страница 14: ...en using the two wrenches Drain Connection CLR2160 CLRCO2175 IMPORTANT IMPORTANT Drain can NOT be located directly below unit Unit has a solid base that will not allow the unit to drain below itself We strongly recommend the use of a U Line drain kit for both gravity pump installations A complete drain kit containing all the items needed to connect your unit are available from your dealer Part No ...

Страница 15: ...er cabinet or attempt to touch any components except the discharge tube during testing 4 Check that the clamps and hose connections are tight at the following areas Discharge tube A Drain tube B Vent tube C 5 Place a suitable container beneath the pump s discharge tube The bucket must be able to hold a minimum of one gallon 6 Plug the ice maker power cord into a properly grounded polarized electri...

Страница 16: ...e event of a pump failure It must have an operating temperature range of 50 F to 110 F 10 C to 40 C IMPORTANT IMPORTANT In the event of a power outage restricted drain or pump failure the failure to use the U Line P60 drain pump or a pump with the above listed specifications could result in substantial water leakage and pooling with severe and costly water damage and related consequential damages ...

Страница 17: ...rst plugged into the electrical outlet Test the drain system by pouring one gallon of water into the ice bin The water should drain freely and there should be no leakage All Models 3 Gently push the unit into position Be careful not to kink the water supply line or entangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top...

Страница 18: ...lution A The hinges should be self closing when the door is open approximately 8 If this is not the case make sure the closers at the bottom of the hinge pin are clean greased and installed correctly Also re check leveling from front to back of the unit and readjust if necessary Make sure that pivot plate is installed correctly Problem Q The custom overlay door was designed to align with the rest ...

Страница 19: ... today The Milwaukee Wisconsin based family operated business provides continuity and vision from which innovations continue to be born Going forward U Line will continue offering best in class products that build on the company s numerous pat ents and world firsts to guide the undercounter industry in realizing its unlimited potential U LINE COM GENERAL INQUIRIES U Line Corporation P O Box 245040...

Отзывы: