background image

QUICK START GUIDE

u-line.com

Environmental Requirements

This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.

This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.

For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.

In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.

Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.

Electrical

SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.

Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.

Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.

Never use an extension cord to connect power to
the unit.

Always keep your working area dry.

NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit

interrupter) is usually not required for fixed location

appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.

See CUTOUT & PRODUCT DIMENSIONS for recommended 

receptacle location.

Door Swing

Units have a zero clearance for the door to open 90

o

, when 

installed adjacent to cabinets.

Stainless steel models require 2-1/8” (54 mm) door 
clearance to accommodate the handle if installed next to a 
wall.

CAUTION

!

5

1/4" Min.

Wall

21"

Wall

21"

16-1/2"

16-1/2"

2" Min.

90°

Door Swing

90°

Door Swing

Black and White Models

2115R Models

Stainless Models

Wall

Wall

21"

16-1/2"

2" Min.

90°

Door Swing

Stainless Steel

21"

16-1/2"

90°

Door Swing

Black, White and Wood Overlay

1/4" Min.

2115WC Models

Wall

Wall

90°

Door Swing

Integrated

Stainless Steel, Black and White

90°

Door Swing

2175R(F) & 2275WC Models

90°

Door Swing

Wall

Wall

21"

25-1/2"

90°

Door Swing

21"

25-1/2"

Stainless Steel

Wood Overlay

2175BEV

90

°

Door Swing

Wall

Wall

90°

Door Swing

Stainless Steel

2175WC Models

2-1/8" Min.

(54 mm)

1/4" Min.

(6 mm)

2-1/8" Min.

(54 mm)

1/4" Min.

(6 mm)

2-1/8" Min.

(54 mm)

1/4" Min.

(6 mm)

Black, White and Integrated

Содержание CDE215F

Страница 1: ...QUICK START GUIDE DISPENSERS CDE215F 115v 1 Tap Beer 30659_B ...

Страница 2: ...sconsin USA and select products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Li...

Страница 3: ...of your product For more details see the complete User Guide Service Manual on u line com CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Door Swing 5 Door Adjustments 6 General Installation 8 Control Operation 14 First Use 14 Airflow Product Loading 16 Cleaning 16 Warranty 20 3 ...

Страница 4: ...t is safe for regular use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in the User Guide Do not damage the refrigerant circuit Service must be done by factory authorized service personnel Any parts shall be replaced with like components Failure to comply could increase the risk of possible ignition due to incorrect part...

Страница 5: ...d to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch ci...

Страница 6: ...nd adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Philips screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 5 Tighten bottom hinge screws 6 Tighten top hinge screws and replace hinge cover REVERSING...

Страница 7: ...using a 1 4 socket 2 Remove corresponding screws on opposite side of cabinet On some models there may be a nut behind one or both screws on either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Install top hinge and door 1 Rotate door 180o and lift the door on to the bottom hinge 2 Install hinge that was used on the opposite side of the unit 3 Align e...

Страница 8: ...er exceed 60 PSI Most draft beers are dispensed between 8 14 PSI and most stouts are dispensed at 30 14 PSI Pressures above 50 PSI will release the built in pressure relief Always connect CO2 tank to regulator Never connect the tank directly to the keg Ventilate area after CO2 leak If it becomes difficult to breathe and your head starts to ache high levels of CO2 may be pres ent LEAVE THE ROOM IMM...

Страница 9: ...p of refrigerator Note Save gasket and cap plug for conversion back to a standard refrigerator 2 Insert tap assembly tubing through the provided gasket and then all the way into the refrigerator 3 Insert and tighten four screws to secure tower to keg refrigerator 4 Install faucet onto the tower Line up teeth on the outside of the faucet with the teeth inside the shank 5 Screw the coupling nut onto...

Страница 10: ...crews included with the kit will accommodate many different countertops For a customized fit it may be necessary to acquire screws that are size to the thickness of your countertop 8 Continue with CO2 and beverage connections NOTE For proper operation of your refrigerator IT IS NECESSARY to install air tight insulation between the refrigerator and the tower The insulation will need to run from the...

Страница 11: ... Installation 12 1 2 TO FRONT FACE OF REFRIGERATOR SEE DIAGRAM A PREVIOUS PAGE 7 1 2 TO SIDE OF REFRIGERATOR 1 4 HOLE 2 3 4 HOLE Template for Countertop Installation Note Verify template has printed true to scale double check hole dimensions and placement 1 Inch ...

Страница 12: ... Attach regulator to CO2 tank Hand tighten the coupling nut and then use an adjustable wrench for an additional quarter turn DO NOT OVER TIGHTEN 3 Attach and clamp CO2 tubing to tap coupler 2 Attach 5 16 CO2 tubing to regulator nipple and clamp into place If necessary make the tubing more pliable by heating the end in boiling water ...

Страница 13: ...r not included 1 Attach and clamp beverage tubing to tap coupler 2 Attach tap coupler to keg Locate notch and rotate clockwise 1 4 turn 3 Press down and rotate clockwise an additional 1 4 turn 4 Open valve on CO2 tank and adjust regulator to desired pressure by turning the handle clockwise 1 4 turn 1 4 turn ...

Страница 14: ... based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit to reach set points before loading To dispense cold coffee make sure the components are assembled according to the instructions in GENERAL INSTALLATION NOTICE First Use Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON OFF Press and hold for 5 seconds Unit will turn ...

Страница 15: ...ll the pin on the sides of the couplers to release built up pressure from the kegs Open the faucets Nothing should come out initially as there is no pressure to the keg Place a container under the faucets and open the valves on the bottom of the regulator Turn the handle clockwise with the faucets open and your beverage will start to pour Stop turning when you get the best flow rate This method sh...

Страница 16: ...tural luster stainless steel surfaces Sanitize the unit when exposed to raw meat juice or human germs such as from a sneeze or being touched by someone who is ill Sanitizing the unit can also be part of regular cleaning routine Stainless Surfaces Stainless door panels handles and frames can discolor when exposed to chlorine gas pool chemicals saltwater or cleaners with bleach Keep your stainless u...

Страница 17: ...ow cleaning solution to flow through it Push base of coupler inward and rotate clockwise 6 Open cleaning pump 7 Empty one packet of cleaner into plastic jar and fill with cool water Closed Pin Open 8 Reassemble pump Continued on next page Beverage Line and Faucet Cleaning Clean the system using a suitable solution designed for beer dispensing systems Beer cleaning kits are also available Solution ...

Страница 18: ... tower Tighten with faucet wrench 11 Pump all the solution through the beverage line 13 Rinse out and refill plastic jar with clean water Pump all the water through the beverage line to rinse 14 Rinse all disassembled parts with clean water 15 Reassemble faucet and reconnect CO2 and beverage lines 12 Allow tap coupler and faucet to soak in drainage bucket and then use faucet brush to clean faucet ...

Страница 19: ...ts can puncture the inner lining or damage the cooling unit DO NOT use any type of heater to defrost Using a heater to speed up defrosting can cause personal injury and damage to the inner lining NOTICE The drain pan was not designed to capture the water created when manually defrosting To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring the unit must be ...

Страница 20: ...od or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U Line will provide either under these warranties or under any warranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of...

Отзывы: