background image

USER GUIDE

u-line.com

Safety and Warning

Safety and Warning

NOTICE
Please read all instructions before installing, 
operating, or servicing the appliance.

Use this appliance for its intended purpose only and follow 
these general precautions with those listed throughout this 
guide:

SAFETY ALERT DEFINITIONS

Throughout this guide are safety items labeled with a 
Danger, Warning, or Caution based on the risk type:

Danger means that failure to follow this safety 
statement will result in severe personal injury or 
death.

Warning means that failure to follow this safety 
statement could result in serious personal injury 
or death.

Caution means that failure to follow this safety 
statement may result in minor or moderate 
personal injury, property, or equipment damage.

This unit contains R600a (Isobutane) which is a
flammable hydrocarbon. It is safe for regular
use. Do not use sharp objects to expedite
defrosting. Do not service without consulting the
“R600a specifications” section included in the
User Guide. Do not damage the refrigerant
circuit.

Service must be done by factory authorized
service personnel. Any parts shall be replaced
with like components. Failure to comply could
increase the risk of possible ignition due to
incorrect parts or improper service.

CALIFORNIA PROPOSITION 65

This product contains chemicals known to the 
state of California to cause cancer and birth 
defects or other reproductive harm.

www.P65warnings.CA.gov

This equipment is to be installed with adequate 
backflow protection to comply with applicable 
federal, state and local codes.

DANGER

!

DANGER

!

WARNING

!

CAUTION

!

CAUTION

!

WARNING

!

4

Содержание Acr115

Страница 1: ...USER GUIDE SERVICE MANUAL Model UACR115 SS01A...

Страница 2: ...ide Installation Water Hookup Anti Tip Bracket General Installation Grille Installation Door Swing Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use...

Страница 3: ...ne RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings and Product Warranty information are availabl...

Страница 4: ...or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting...

Страница 5: ...n place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of re...

Страница 6: ...mperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat genera...

Страница 7: ...he unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has be...

Страница 8: ...in the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS 15 Cutout width sufficient if door protrudes beyond adjacent cabinetry PRODUCT DIMENSIONS REAR FRONT TOP S...

Страница 9: ...ed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as show...

Страница 10: ...The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged during installation WARNING Conne...

Страница 11: ...filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn on water supply and check for leaks 8 R...

Страница 12: ...ver holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water li...

Страница 13: ...n opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is...

Страница 14: ...unit the grille must be installed Removing the grille 1 Disconnect power to the unit 2 Slightly loosen three screws on bottom hinge 3 Remove two grille screws 4 Slide grille to the left and remove Ins...

Страница 15: ...tainless Steel 16 1 2 90 Door Swing Black White and Wood Overlay Wall Wall 90 Door Swing Integrated Stainless Steel Black and White 90 Door Swing 2175R F 2275WC Models 90 Door Swing Wall Wall 21 25 1...

Страница 16: ...from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver on the top and a 1 4 socket on the bottom 3 Align door squarely with cabinet 4 Make sure gasket is fi...

Страница 17: ...pulling outward exposing the gasket channel 3 Remove the 3 pieces of gasket channel filler and reinstall on the opposite end of door 4 Install gasket into channel beginning at one corner and pressing...

Страница 18: ...U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line To turn the unit on or off Press th...

Страница 19: ...s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp instrument to separate cubes Shake the ice b...

Страница 20: ...ge of an adjustment to the screw can cause the water to overflow the ice maker and can cause property damage 3 Turn the adjusting screw toward the minus sign clockwise for smaller cubes or toward the...

Страница 21: ...u line com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected D...

Страница 22: ...non chlorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this includes glass tile and counter cleaners If any surface discoloring or rusting a...

Страница 23: ...discard ice 3 Place towel or other absorbent material on bottom of ice bin 4 Fill the ice bucket half full with warm not hot water This will help the unit defrost faster 5 Place the ice bucket back i...

Страница 24: ...ronmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condenser...

Страница 25: ...n the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and milde...

Страница 26: ...ency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain a...

Страница 27: ...setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door drawer openings and the time the door drawer is open The time the internal light is...

Страница 28: ...GHT BLUE WHITE DARK BLUE BLACK BROWN BLACK BROWN WHITE DARK BLUE BIN SW NO NC C WATER SW NC NO C H O L D S W N O N C C CAM 3 RPM MOTOR LIMIT SW MOLD HEATER YELLOW BLACK RED WHITE WHITE DARK BLUE BROWN...

Страница 29: ...nt of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial numb...

Страница 30: ...shes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may su...

Страница 31: ...54568 01 9 CONTROL KNOB 80 54382 00 10 DOOR SOLID SS 15 ADA 80 54389 01 11 FACEPLATE 115V 80 54523 00 12 GASKET DOOR 80 55428 01 13 GRILLE W SCREWS 80 54385 00 14 HINGE ASSEMBLY 80 55595 00 15 ICE BU...

Страница 32: ...s will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U L...

Страница 33: ...Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near ro...

Страница 34: ...tatic wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across t...

Страница 35: ...ce Bin switch inoperable closed Replace bin switch Bin arm binding Lubricate bin arm pivot points or loosen bin arm lever screw Water will not stop filling Water switch inoperable closed Replace water...

Страница 36: ...fill tube assembly Defrost drain line not in drain pan Position drain line in drain pan Crack in water line Replace water line Water leak inside unit Ice maker assembly fill cup obstructed Remove obst...

Страница 37: ...tage Voltage Drop Wiring Temperature Control Failure Water Adjustment Bin Switch Failure NO NO EVERYWHERE INTERMITTENT AT 3 00 YES NO AT 12 00 DOES THE UNIT HARVEST ICE IF THE EJECTOR BLADES ARE MOVED...

Страница 38: ...2 and 3 are closed Power to the condenser Power to the condenser fan Figure 1 Freeze Cycle SWITCH LIMIT orange black black black MOTOR MAKER ICE MOLD HEATER WATER SWITCH FILL C NC MOTOR FAN LOAD OVER...

Страница 39: ...power goes through bin arm switch to the ice maker motor If bin arm is up the ice maker will not harvest Figure 2 Harvest 1 Cycle Hold Switch in Normal Position SWITCH LIMIT orange black black black M...

Страница 40: ...r motor and mold heater Ejector blades stall on ice and ice maker motor pulsates until mold heater warms and ice releases Figure 3 Harvest 2 Cycle Hold Switch in Switched Position SWITCH LIMIT orange...

Страница 41: ...T CYCLE Ejector blades push ice into bucket and stop at 12 00 position Temperature control terminals 2 and 3 have closed during harvest cycle Next freeze cycle begins with power to the compressor and...

Страница 42: ...rature After ice is sensed in the mold the 2 3 contacts open stopping the compressor and the 2 1 contacts are closed starting the ice maker motor The 2 3 contacts close 2 1 contacts open before the en...

Страница 43: ...ch Open temperature 104 F Close temperature 83 F The function of this switch is to open in the event of an overheating condition This bi metal thermostat is normally closed and does not initiate the i...

Страница 44: ...t tube 5 Remove front cover 3 6 Advance the ejector blade to the 3 o clock position by turning the 5 16 hex head on the small brass gear counterclockwise 4 7 Remove three screws from wall of freezer h...

Страница 45: ...evaporator shelf 11 Apply 1 4 layer of fresh alumilastic to heater side of new ice maker 12 Replace parts in reverse order of removal 13 Reconnect all wires 14 Insert capillary tube into ice maker se...

Страница 46: ...defrost unit remove ice bucket Turn unit off Use toweling inside to absorb water as it melts down This will help prevent water from getting onto customer s floor The defrost duration is dependent upo...

Страница 47: ...lectricity has been disconnected 2 Disconnect ice maker wire harness at plug 3 Disconnect thermistor plug 4 Remove water inlet tube 5 Remove three screws from wall of freezer housing 6 Remove ice make...

Страница 48: ...d or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U...

Отзывы: