Water line leaking at solenoid valve outlet
■
Replace water line and fitting
■
Water line leaking at fill tube
■
Tighten clamp or fill tube replace fill tube
assembly
■
Defrost drain line not in drain pan
■
Position drain line in drain pan
■
Crack in water line
■
Replace water line
13. Water leak (inside unit)
Cause
Remedy
■
Ice maker assembly fill cup obstructed
■
Remove obstruction.
■
Fill ice cup and fill tube out of alignment
■
Align fill tube and fill cup
■
Water level too high
■
Adjust water level
■
Defrost drain plugged
■
Ice in drain trough (refer to #16)
14. Excessive frost build-up
Cause
Remedy
■
Door gasket not sealing properly
■
Adjust door hinges or replace door gasket
■
Door out of alignment
■
Adjust door hinges
■
Water soaked cabinet insulation
■
Replace foamed cabinet assembly
(factory repair only)
■
Light stays on when door is closed
■
Repair or adjust light bracket
15. Noisy
Cause
Remedy
■
Copper refrigeration tube touching cabinet
■
Carefully adjust tubing
■
Fan blade touching shroud
■
Adjust fan mounting or shroud
■
Fan blade obstruction (wiring, foam
■
Remove obstruction
insulation, packaging material)
16. Ice build-up in drain trough or drainage problem (see page 20)
Cause
Remedy
■
Obstructed drain cup or tube
■
Clear obstruction
■
Evaporator not touching drain trough
■
Reposition evaporator to contact
drain
trough along entire length
■
Kinked drain tube
■
Reroute drain tube
■
Drain trough spout and drain cup
■
Align drain trough and drain cup
not aligned
17. Unit will not defrost
Cause
Remedy
■
Bypass valve bent (will not operate)
■
Align bypass valve and coil assem-
bly
■
Bypass coil defective
■
Replace bypass valve
■
Defrost timer defective
■
Replace defrost timer
■
Bypass valve defective
■
Replace bypass valve
18. Fresh food temperature too cold
Cause
Remedy
■
Ice bucket not fully inserted
■
Push ice bucket in place
■
Temperature control set too cold
■
Adjust control to warmer setting
(counterclockwise)
■
Air leak at evaporator cover
■
Seal cover with RTV